Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 CrRejected-Finance | ₹1.8 Cr | L-1 | Rejected-Finance BANK GUARANTEE HAS BEEN SUBMITTED IN OFFICE, |
| 2 | L-2₹2.0 Cr+₹18.5 L (10.2%)Rejected-Finance | ₹2.0 Cr+₹18.5 L (10.2%) | L-2 | Rejected-Finance HIGHLY QUOTED |
Tender Value
₹2.0 Cr
EMD Value
₹99,640
Closing Date
29 Jan 2024, 5:30 pmClosed
Rajesh kumar Saxena
3rd floor HFA Cell ISBT building BMC office bhopal
External Electrification work at Bagmugaliya site. (Second Call)
2023_UAD_268110_2
CEP/16/ HFA
Open Tender
Electrical Works
Percentage
30 days
3rd floor HFA Cell ISBT building BMC office bhopal
as per tender requirement
13 documents required · 13 mandatory
₹12,500
₹99,640
24 Sept 2024
11 Jan 2024
30 Jan 2024
11 Jan 2024
29 Jan 2024
11 Jan 2024
Amount
External Electrification work at Bagmugaliya site
3000010215-ACSR 0.1 sq inch (100 Sq.mm Al. EQ. ) - Supplying and drawing of stranded Aluminium Conductor Steel Reinforced (ACSR) confirming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc. ACSR 0.1 sq inch (100 Sq.mm Al. EQ. ) - (Dog).
3000010233-CT PT combined unit, 300-150/5Amp. Supplying, installation, testing and commissioning of oil immersed, .5 accuracy class, 50 Hz CT PT combined unit complete with all other materials as required including testing / calibration charges of Electricity board as required. CT PT combined unit, 300-150/5Amp.
3000012273-33KV (45 KN) polymer disc insulators Supplying and erection of 33KV (45 KN) polymer disc insulators for 33KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required.(AS per Pwd SOR 2020)
3000012272-33KV (10 KN) polymer pin insulator Supplying and erection of 33KV (10 KN) polymer pin insulator complete with long steel head G.I. pin, nut, washer etc. as required.(Aa per pwd sor 2020)
3000012342-CT/PT ratio 400- Supply, installation, testing & commissioning of HT 33 KV/110 V 3P4W CT/PT ratio 400-200/5 Amp outdoor oil immersed type duly tested from electricity board. AS PER MP PWD SOR 2020
3000010216-ACSR PANTHER CONDUCTOR 0.20 SQ. INCH (2 Supplying and drawing of stranded Aluminium Conductor Steel Reinforced (ACSR) confirming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc.
3000010231-12 core x 2.5 sqmm. copper cable. Supplying, laying connecting and testing of PVC/XLPE heavy duty control cable confirming to relevant IS specifications 1100 volts grade armoured of approved make with copper conductor in existing trench with clamp as required. The rate include for making cable end termination with suitable size brass cable gland and copper lugs etc. complete as required. 12 core x 2.5 sqmm. copper cable.
3000010228-2 core x 2.5 sqmm. copper cable. Supplying, laying connecting and testing of PVC/XLPE heavy duty control cable confirming to relevant IS specifications 1100 volts grade armoured of approved make with copper conductor in existing trench with clamp as required. The rate include for making cable end termination with suitable size brass cable gland and copper lugs etc. complete as required. 2 core x 2.5 sqmm. copper cable.
3000010229-4 core x 2.5 sqmm. copper cable. Supplying, laying connecting and testing of PVC/XLPE heavy duty control cable confirming to relevant IS specifications 1100 volts grade armoured of approved make with copper conductor in existing trench with clamp as required. The rate include for making cable end termination with suitable size brass cable gland and copper lugs etc. complete as required. 4 core x 2.5 sqmm. copper cable.
3000010230-8 core x 2.5 sqmm. copper cable. Supplying, laying connecting and testing of PVC/XLPE heavy duty control cable confirming to relevant IS specifications 1100 volts grade armoured of approved make with copper conductor in existing trench with clamp as required. The rate include for making cable end termination with suitable size brass cable gland and copper lugs etc. complete as required. 8 core x 2.5 sqmm. copper cable.
3000012331-XLPE aerial bunch 3x25 sq.mm, 1x16(st. light), 1x35(insulated neutral messenger) AS PER MP PWD SOR 2020
3000012347-Aerial bunch cable Supplying & fixing of aerial bunch cable accessories suspension clamp i/c required attachment for single core cable of approved make on pole with clamp, necessary material as per specification for required size. AS PER MP PWD SOR 2020
3000012348-Aerial bunch cable Supplying &fixing of aerial bunch cable accessories tension clamp (dead end) i/c required attachment for single core cable of approved make in air with clamp, necessary material as per specification for required size. AS PER MP PWD SOR 2020
3000012349-Piercing connector Main:16-95sq.mm, tap:1.5-50sq.mm AS PER MP PWD SOR 2020
3000012351-Spring loaded Supplying &fixing of spring loaded busbar screwless connector with enclosure of approved make including required clamp, nut, bolt, connection, testing as per specification to complete the job. Single phase 1Ph, 1In+2Out AS PER MP PWD SOR 2020
3000003611-100 KVA transformer Supplying, installing, testing and commissioning of 11/0.4 K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out door type transformer connected delta on H.T. side and star on L.T. side, hand operated off load Tap changer switch above 100 kVA, oil conservator with drain valve, plug 63 KVA and above, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required as per IS specification. Marked ISI & 3 Star rating. Aluminium wound 100 kVA as per MPPWD SOR.
3000012321-Construction of pedestal (plinth) Designing and construction of pedestal (plinth) for transformer of desired size including excavation in hard rock/soft rock, base concrete M-7.5 (1:4:8), 20mm metal and pedestal of RCC M-15 (1:2:4) including required tar steel reinforcement for required height as per IE rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortar 1:3 curing & white washing etc. complete as per specifications. AS PER MP PWD SOR
4000000784-Covered conductor 70 Sq. Mm. XLPE insula Covered conductor 70 Sq. Mm. XLPE insulation for 11 KV
3000013647-Covered conductor 99 Sq. Mm. XLPE insula Covered conductor 99 Sq. Mm. XLPE insulation for 11 KV
3000012793-Covered conductor 33 Kv grade 95 Sqm Covered conductor 33 Kv grade 95 Sqm Supplying and laying of 33 KV grade covered conductor 95 sqmm.of specification As per MPMKVVCL
3000010222-static trivector meter CT operated 3 Ph. 4 Wire, 0.5 accuracy class 11/33 KV HT static trivector meter with TTB & modem including XLPE insulated & P.V.C. sheathed 12 core x 1.5 Sqmm armoured copper conductor cable of required length.
3000010227-11 KV/110V PT Supplying, installation, testing and commissioning of oil filled out door type single phase, 50 Hz, 33 KV/110 V, or 11 KV/110V, 100VA burden, class 1.0 voltage transformer complete as per IS 3156 11 KV/110V PT
3000010225-11 KV Isolator 400/600 Amp. with earth s Supplying installation testing and commissioning of 400/600 Amp. triple pole outdoor type two stack and three Insulator padestals per phase, manual operated rotating type Isolator complete with fixed and moving contact of hard drawn electrolytic copper flat, 8 mm dia GI rod for fixed and moving arching horn, 32 mm dia GI pipe for operating handle, 19mm dia GI pipe for phase coupler, brass bush and trust bearing, isolator base channel, post insulator, padlock with key, earth/without earth switch and other required accessories etc. complete as required. 11 KV Isolator 400/600 Amp. with earth switch (set of 3 Nos for 3 phases)
3000011089-11KV C.T.’s outdoor dry type 200-100/5Am Supplying, installation, testing and commissioning of 11KV C.T.’s outdoor dry type 200-100/5Amp unit complete with all other materials as per MPMKVVCL specification required including testing / calibration charges of Electricity board as required.
3000011088-11KV C.T.’s outdoor dry type 300-150/5Am Supplying, installation, testing and commissioning of 11KV C.T.’s outdoor dry type 300-150/5Amp unit complete with all other materials as per MPMKVVCL specification required including testing / calibration charges of Electricity board as required
3000010244-11 KV CONTROL (2F) Supplying, installation, testing and commissioning of 11 KV CONTROL & RELAY PANEL WITH SCADA COMPATIBLE FOR FEEDER PROTECTION (2F) The complete work should be done as per IS & MPMKVVCL specification.
3000010242-11 KV CONTROL & RELAY PANEL WITH SCADA Supplying, installation, testing and commissioning of 11 KV CONTROL & RELAY PANEL WITH SCADA COMPATIBLE FOR TRANSFORMER PROTECTION (2T) The complete work should be done as per IS & MPMKVVCL specification.
3000010226-33 KV/110V PT Supplying, installation, testing and commissioning of oil filled out door type single phase, 50 Hz, 33 KV/110 V, or 11 KV/110V, 100VA burden, class 1.0 voltage transformer complete as per IS 3156 33 KV/110V PT
3000010224-33 KV Isolator 400/600 Amp with earth sw Supplying installation testing and commissioning of 400/600 Amp. triple pole outdoor type two stack and three Insulator padestals per phase, manual operated rotating type Isolator complete with fixed and moving contact of hard drawn electrolytic copper flat, 8 mm dia GI rod for fixed and moving arching horn, 32 mm dia GI pipe for operating handle, 19mm dia GI pipe for phase coupler, brass bush and trust bearing, isolator base channel, post insulator, padlock with key, earth/without earth switch and other required accessories etc. complete as required. 33 KV Isolator 400/600 Amp with earth switch (set of 3 Nos. for 3 phases)
3000010269-SCADA COMPATIBLE FOR FEEDER PROTECTION Supplying, installation, testing and commissioning of 33 KV CONTROL & RELAY PANEL WITH SCADA COMPATIBLE FOR FEEDER PROTECTION (FOR 2 FEEDER) . The complete work should be done as per IS & MPMKVVCL specification.
3000010239-33 KV CONTROL & RELAY PANEL WITH SCADA C Supplying, installation, testing and commissioning of 33 KV CONTROL & RELAY PANEL WITH SCADA COMPATIBLE FOR TRANSFORMER PROTECTION . The complete work should be done as per IS & MPMKVVCL specification.
3000010237-33/11 KV Power transformer 33/11 KV Power transformer , OFTC Type 5000 KVA Loss (4 KW + 23 KW) Supplying installing, connecting, testing and commissioning of 3 Phase, 50 Hz, 33/11 KV, Delta/Star connected ONAN cooling, step down, Copper wound, oil filled, Indoor/outdoor type, power transformer of accepted standard specification with accessories such as drain & filter valve, earthing terminals, lifting arrangements of suitable size, dehydrating breather with silica gel of suitable size, Conservator tank, air release devise, Rating & diagram plate, CI rollers, Radiators with shut off valve, Explosion vent with diaphragm, Off load tap changing switch, Buchholz relay, thermometer pocket with 6" dial type thermometer & OTI including Cable end boxes on HT & LT side bushings wherever required complete with first filling of oil with installation on existing foundation etc. complete as per specification. The no load and full load losses should not be more than as per MPMKVVCL specifications
3000010222-static trivector meter CT operated 3 Ph. 4 Wire, 0.5 accuracy class 11/33 KV HT static trivector meter with TTB & modem including XLPE insulated & P.V.C. sheathed 12 core x 1.5 Sqmm armoured copper conductor cable of required length.
3000014196-Concreting (1:3:6) of Isolator Support S Earth work in excavation for foundation, trenches for pipes/ cables or drains etc.by mechanical means/ manual means (exceeding 30 cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. Concreting (1:3:6) of Isolator Support Structure @0.1 CMT. Per Structure as per electricity board required
3000010264-Marshelling box with 10 no. connectors Supplying, installation, testing and commissioning of Marshelling box with 10 no. connectors The complete work should be done as per IS & MPMKVVCL specification.
3000010223-energy meter CT operated 3 Ph. 4 Wire, 0.5 accuracy class LT DTR energy meter with LPR feature including GSM, modem etc. with 4 No. resin moulded 100/5 or 200/5 or 300/5 ratio LT CT 3000003705 DTR meter.
3000012518-BORING for tube well /G3 type earthing BORING for tube well /G3 type earthing
3000015507-Unarmoured 1 core 70 sq mm Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor Unarmoured 1 core 70 sq mm As per MPPWD SOR 2022
3000015508-XLPE Unarmoured 1 core 150 sq mm Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor Unarmoured 1 core 150 sq mm as per MPPWD sor 2022
3000015509-PTR Foundation Construction of PTR Foundation as per drawing approved from MPMKVVCL
3000015510- 2 KVA ups (for LDMS) with 160 AH Batter Supply ,installation, testing and commissioning of 2 KVA ups (for LDMS) with 160 AH Battery As per MPEB SOR item code no M-0901027
3000015511-2 MBPS vpn link for connectivity Supply ,installation, testing and commissioning of 2 MBPS vpn link for connectivity for s/s with SCADA control centerl As per MPEB SOR item code no M-0001330
3000015512-48V DC POWER SUPPLY SYSTEM BASED ON SMPS Supply ,installation, testing and commissioning of 48V DC POWER SUPPLY SYSTEM BASED ON SMPS FOR RTU & COMM. EQUIP WITH 80AH BATTRY As per MPEB SOR item code no M-0909010
3000015513- CAT 6 CABLE Supply ,installation, testing and commissioning of CAT 6 CABLE As per MPEB SOR item code no M-0909114
3000015514-Contact multiplying relay Supply ,installation, testing and commissioning of Contact multiplying relay As per MPEB SOR item code no M-0204111
3000015515- Contractors 30 V DC, 10 Amp Supply ,installation, testing and commissioning of Contractors 30 V DC, 10 Amp As per MPEB SOR item code no M-1601246
3000015516-Copper Control Cable 2 Core, 2.5 Sq.mm. "Supply ,installation, testing and commissioning of Copper Control Cable 2 Core, 2.5 Sq.mm. (Unarmoured) As per MPEB SOR item code no M-0402237"
3000015517-Copper Control Cable 4 Core. 2.5 Sq.mm. "Supply ,installation, testing and commissioning of Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) As per MPEB SOR item code no M-0402239"
3000015518-Copper Control Cable 8 Core. 2.5 Sq.mm. "Supply ,installation, testing and commissioning of Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) As per MPEB SOR item code no M-0402243"
3000015519-Electromechnical isolation contacts "Supply ,installation, testing and commissioning of Electromechnical isolation contacts As per MPEB SOR item code no M-0204113"
3000015520-Fire extinguisher cartridge CO2 10 kgs "Supply ,installation, testing and commissioning of Fire extinguisher cartridge CO2 10 kgs As per MPEB SOR item code no M-1001008"
3000015521-Heavy duty relays for CB Trip/close "Supply ,installation, testing and commissioning of Heavy duty relays for CB Trip/close As per MPEB SOR item code no M-0204112"
3000015522-LASER PRINTER "Supply ,installation, testing and commissioning of LASER PRINTER As per MPEB SOR item code no M-0903001"
3000015523-LDMS "Supply ,installation, testing and commissioning of LDMS As per MPEB SOR item code no M-0901022"
3000015524-LDMS software "Supply ,installation, testing and commissioning of LDMS software As per MPEB SOR item code no M-0913032"
3000015525-Multi function transducers "Supply ,installation, testing and commissioning of Multi function transducers As per MPEB SOR item code no M-0909112"
3000015526-Oil temperature indicator (OTI), "Supply ,installation, testing and commissioning of Oil temperature indicator (OTI), Dial 150mm, with capilary, Mercury swicth type As per MPEB SOR item code no M-0118081"
3000015527-RTU base and foundation (base should be "Supply ,installation, testing and commissioning of RTU base and foundation (base should be capable of with standing 200 kg. Load) As per MPEB SOR item code no M-0909117"
3000015528-Remote Terminal Unit (rtu) including sof "Supply ,installation, testing and commissioning ofRemote Terminal Unit (rtu) including software for 2 no. Power transformer As per MPEB SOR item code no M-0204119"
3000015529-Winding Temperature Indicator "Supply ,installation, testing and commissioning of Winding Temperature Indicator Dial 150mm with Capillary, Mercury Switch type As per MPEB SOR item code no M-0118080"
Bidder Name
Amount
RIGHTWAYS CONSTRUCTIONS(GSTN-23ATGPK9601E1ZZ)
SURPLUS RESOURCE ENTERPRISES(GSTN-23AHHPJ3858R1ZQ)
SURPLUS RESOURCE ENTERPRISES
SURPLUS RESOURCE ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .