Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹30.4 LAdmitted-Finance | -26.51% | ₹30.4 L | L1 | Admitted-Finance |
| 2 | L2₹32.2 LAdmitted-Finance | -22.11% | ₹32.2 L | L2 | Admitted-Finance |
| 3 | L3₹38.6 LAdmitted-Finance | -6.63% | ₹38.6 L | L3 | Admitted-Finance |
| 4 | L4₹40.7 LAdmitted-Finance | -1.51% | ₹40.7 L | L4 | Admitted-Finance |
| 5 | L5₹40.9 LAdmitted-Finance 224 KAILASH NAGAR SHOBHAPUR COLONY DISTRICT BETUL MADHYA PRADESH PIN 460449 | BETUL | MADHYA PRADESH | 460449 | -1.11% | ₹40.9 L | L5 | Admitted-Finance |
Tender Value
₹41.3 L
EMD Value
₹82,640
Closing Date
5 Mar 2026, 2:00 pmClosed
EXECUTIVE ENGINEER PHED DIVISION KOLAYAT
EXECUTIVE ENGINEER PHED DIVISION KOLAYAT
CONSTRUCTION AND COMMISSIONING OF TUBEWELL AND INTERCONNECTION OF TUBEWELL WITH GLR AT KOTRI
2026_PHCJA_541712_1
115/2025-26
Open Tender
Civil Works
Kolayat
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EXECUTIVE ENGINEER PHED DIVISION KOLAYAT
₹82,640
Yes
27 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
Part A :- Construction & Commissioning of tube well
Construction of Tube Well from ground level and upto 100 mtr. depth and above to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 (part 1 & 2) 1979 as amended up to date. The work will include cost of lowering of housing, strainer assembly pipes, with supply and wrapping of coir rope, wherever necessary and development of tube well as per IS specification using suitable Air Compressor but will not include cost of casing & strainer pipe. Work will be completed after obtaining sand free water. Nominal bore 250 mm dia.
Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and upto 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .
Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. Nominal bore 200 mm dia.
Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 as amended up to date.
Development of tube well as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable compressor to give sand free water for required yield of the gravel packed tube well.
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of grade Fe 410 of following sizes 250 mm dia NB (Thicknee of pipe 7.1 mm & mass of tube 46.57 Kg/m)
Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 250 mm dia nominal bore of 7.1mm thickness
Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2011 (pump) and IS 9283-2013 (motor) or amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 15 KW (20 HP) and above, head above 120 mtr.
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. Above 15 HP and up to 20 HP
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 10.0 mm2
Supply & Fixing of PVC insulated sheated (heavy duty) armourd electric cable with aluminium conductor for working voltage to Is:7098 Part-I/IS :1554 Part-I applicable. 3.5 core 35.0 mm2
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both end in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate (as per drawing enclosed). A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 250 mm dia
Providing & Lowering in tubewell ISI marked GI Pipe “B" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 65 mm dia
Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes 80 mm dia
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.
Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 80 mm dia
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month. (For Urban water Supply Scheme) 16 to 25 HP
Part B :- Providing, Laying and jointing of pipe line as rising main
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80 PN-6 90 mm dia
90 mm dia
110 mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Part C :- Construction of RCC Dome type Ground level service reservoir (GLSR) 100 KL
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 100 KL capacity
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
TD115.pdf
Tender Documents • 1.51 MB
BOQ_965666.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid