| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹2.4 L+₹21,996.86 (9.93%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹2.6 L+₹42,534.53 (19.2%)Rejected-Finance | L3 | Rejected-Finance Highest |
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
16 Apr 2021, 5:00 pmClosed
Amit Manuja
Executive Engineer, Provincial Division No.1, PWD B and R, Kurukshetra
Special Repair / Renovation of Sub Health Centre at Village Mohanpur in District Kuruksetra (Under Health Wellness Centre Scheme) (Excluding E1)
2021_HRY_166258_2
PWD/AMB/KKR-1/110120
Open Tender
Construction Works
Works
60 days
Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹5,000
30 May 2021
10 Apr 2021
19 Apr 2021
10 Apr 2021
16 Apr 2021
10 Apr 2021
Amount
Dismantling Roofing removing RCC Battens from Roof HSR 8.8 (h).
Scraping Cement plaster (HSR 8.32 (c) )
Cement concrete 1: 1.1/2 : 3 with stone aggregate 20 mm nominal size for reinforced conctete work for walls exceeding 20cms thickness (straight & curved) beams, girders, stairs, columns, (Square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering laid in position, complete in all respect. (HSR 10.86 + 10.95 (a))
Providing and laying 80 mm thick ISI marked interlocking paver blocks conforming to IS 15658:2006 /IRC:SP:63-2004 of all Shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.159).
First class brick work laid in cement sand mortar 1:4 in first storey up to 4 meters above plinth level.(HSR 11.9)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm, laid over 87.50 mm mud filling, on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles including two coats of bitumen laid hot at 1.65 kg per sqm on top of RCC slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Providing & Fixing 100 mm PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (a) 100 mm dia PVC pipe 6 kg. pressure. (Make Supreme, Phinolex, Prince or equvalent)(HSR-13.89 (a))
Providing and fixing vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:-Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, BELL, JOHNSONS.& RAK AND SIMPOLO. (HSR 14.89)
Pdg & fixing ceramic tiles/anti skid tiles of size 400mm x 400mm or above size of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note:-Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, BELL, JOHNSONS.& RAK AND SIMPOLO. (HSR 14.91)
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete.(HSR 14.92) (b) 300mm x 450mm
Plastering on walls 12 mm thick cement plaster 1:5 (HSR 15.6)
Painting two coats with synthetic enamel paint in all shades on old wood-work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.(HSR 16.5)
Distempering with washable oil bound distemper (of approved manufacture ) two coats over one priming coats on new work. (HSR 16.58)
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete (JK/ Birla make) (HSR 16.81)
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights / depths / storeys / basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22 )
Supplying & fixing glass panes including special metal sash putty of approved make (b) glass panes 4 mm thick, exceeding 40sq dm areas. (HSR 18.30 (b) )
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].
Providing and fixing in position best Indian make (Ordinary ) lavaatory suites white consisting of lavatory in Vitreous chinaware size as given below to the approval of the Engineer In Chargeietc (i) 460mm x300mm with one no. tab. (iv) Size 550mm x 400mm with one no. tab(HSR- 30.41-(iv)
PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48].
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large. [HSR 30.70 (a) (i)].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].
Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)].
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 1000 Ltrs. Capacity Water Tank
Providing and laying 200 mm thick granular sub base consisting of drainage layer confirming to Table 400.1 Grading –VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013. (NS).
The Jagat co op L and C Society ltd
SUS MANPOWER AGENCY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .