Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹6.8 L+₹53,023.55 (8.51%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹6.8 L+₹53,950.05 (8.66%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | S.Ramasubramanian L2 | Selvam Construction L1 | Navaneethakrishnan L3 |
|---|---|---|---|---|---|---|
| 1.00Repairs and Renovation to the Anganwadi building at Asirvathapuram Village in Kadayam Perumpathu Panchayat in Kadayam Panchayat Union Under Panchayat Union General Fund - 2026 - 27 | ||||||
| 2.00 | Dismantling the damaged AC Sheet Roof including all cost and conveyances of materials and all labour charges etc complete., | 61.19 | Sqm | 18 ₹1,101.42 | 15 ₹917.85 Lowest | 18.5 ₹1,132.02 |
| 3.00 | Providing and Fixing of polyurethane foam for Sloped profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification etc complete., 60mm (+38mm) thick PUF roof panel | 61.19 | Sqm | 2,904 ₹1,77,695.76 | 2,450 ₹1,49,915.5 Lowest | 2,905 ₹1,77,756.95 |
| 4.00 | Brick work in CM 1:5 mix using third class country bricks of size 8 3/4 x 4 1/4 x 2 3/4 including all cost and conveyance of materials and labour charges etc., complete. | 0.58 | Cum | 6,075 ₹3,523.5 | 6,000 ₹3,480 Lowest | 6,077 ₹3,524.66 |
| 5.00 | Cement concrete 1:4:8 mix using 40mm ISS HBG metal including all cost and conveyance and all labour charges etc., complete | 3.59 | Cum | 5,357 ₹19,231.63 | 5,200 ₹18,668 Lowest | 5,359 ₹19,238.81 |
| 6.00 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work | 6.24 | Sqm | 7,480 ₹46,675.2 | 7,400 ₹46,176 Lowest | 7,482 ₹46,687.68 |
| 7.00 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays,handles should be screwed with self tapping screws. The handles, locks should be designedso that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 7.56 | Sqm | 8,311 ₹62,831.16 Lowest | 8,400 ₹63,504 | 8,313 ₹62,846.28 |
| 8.00 | Finishing the top of roof with one course of PRESSED TILES of size 23 cm X 23 cm X 2 cm laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound conforming to I.S. at 2% by weight. | 4.38 | Sqm | 1,322 ₹5,790.36 | 1,250 ₹5,475 Lowest | 1,324.5 ₹5,801.31 |
| 9.00 | Paving the floor with best quality Vetrified ( Such as Morbonite) Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. | 42.35 | Sqm | 1,126 ₹47,686.1 | 1,000 ₹42,350 Lowest | 1,127.9 ₹47,766.57 |
| 10.00 | Plastering with CM 1:5 mix using to 12mm thick including all cost and conveyance of all materials and all labour charges etc., complete | 63.51 | Sqm | 282 ₹17,909.82 | 270 ₹17,147.7 Lowest | 282.5 ₹17,941.58 |
Tender Value
₹7.3 L
EMD Value
₹7,330
Closing Date
23 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Block Development officer,B.Pt
Block Development Officer ( B.Pt ), Panchayat Union, Kadayam.
Repairs and Renovation to the Anganwadi building at Asirvathapuram Village in Kadayam Perumpathu Panchayat of Kadayam Panchayat Union Under Panchayat Union General Fund - 2026 - 27
2026_RDTN_721312_4
BDKDM/463/2026-A2
Open Tender
Civil Works
Works
Kadayam
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹7,330
24 Nov 2026
3 Nov 2026
23 Nov 2026
3 Nov 2026
23 Nov 2026
3 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairs and Renovation to the Anganwadi building at Asirvathapuram Village in Kadayam Perumpathu Panchayat in Kadayam Panchayat Union Under Panchayat Union General Fund - 2026 - 27 | - | - | - | - |
| 2 | Dismantling the damaged AC Sheet Roof including all cost and conveyances of materials and all labour charges etc complete., | 61.19 | Sqm | 18.9 | ₹1,156.49 |
| 3 | Providing and Fixing of polyurethane foam for Sloped profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification etc complete., 60mm (+38mm) thick PUF roof panel | 61.19 | Sqm | 2,905 | ₹1,77,756.95 |
| 4 | Brick work in CM 1:5 mix using third class country bricks of size 8 3/4 x 4 1/4 x 2 3/4 including all cost and conveyance of materials and labour charges etc., complete. | 0.58 | Cum | 6,077.27 | ₹3,524.82 |
| 5 | Cement concrete 1:4:8 mix using 40mm ISS HBG metal including all cost and conveyance and all labour charges etc., complete | 3.59 | Cum | 5,359.62 | ₹19,241.04 |
| 6 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work | 6.24 | Sqm | 7,482 | ₹46,687.68 |
| 7 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays,handles should be screwed with self tapping screws. The handles, locks should be designedso that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 7.56 | Sqm | 8,313 | ₹62,846.28 |
| 8 | Finishing the top of roof with one course of PRESSED TILES of size 23 cm X 23 cm X 2 cm laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound conforming to I.S. at 2% by weight. | 4.38 | Sqm | 1,324.64 | ₹5,801.92 |
| 9 | Paving the floor with best quality Vetrified ( Such as Morbonite) Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. | 42.35 | Sqm | 1,127.91 | ₹47,766.99 |
| 10 | Plastering with CM 1:5 mix using to 12mm thick including all cost and conveyance of all materials and all labour charges etc., complete | 63.51 | Sqm | 282.8 | ₹17,960.63 |
stage.html
html • 0.02 MB
finance_866164.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.45 MB
BOQ_866164.xls
BOQ • 0.33 MB
Corigenextension.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .