Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.3 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.3 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.4 Cr+₹4.7 L (3.46%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹1.4 Cr+₹4.7 L (3.46%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹1.4 Cr+₹5.1 L (3.78%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.4 Cr+₹5.1 L (3.78%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹1.4 Cr+₹5.6 L (4.13%)Rejected-Finance | ₹1.4 Cr+₹5.6 L (4.13%) | L-4 | Rejected-Finance Being L-4 |
| 5 | L-5₹1.4 Cr+₹5.8 L (4.33%)Rejected-Finance COLABA MUMBAI | ₹1.4 Cr+₹5.8 L (4.33%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
25 Nov 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
OUTSOURCING OF SERVICES FOR MANNING AND OPERATION OF AC PLANTS AT NAD, DG SET, PUMPS, AMF PANEL AT 31 WEU THANE, AND FIRE FTG INSTAL AT NSD STORE, WED AND PUMP HOUSE AT MINE WORKSHOP AT TANAJI, SPDC, NAD TROBMAY AS SPECIFIED IN SCOPE OF WORK
2024_MES_680627_1
8885/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.1 L
Yes
10 Jan 2025
22 Oct 2024
28 Nov 2024
22 Oct 2024
25 Nov 2024
12 Nov 2024
Amount
Mannual Rescue and Operation Rescue of Central AC Plants [Installation consisting of AC plant with chilled water system 150 TR capacity having 03 Nos compressors each of 75 TR capacity (02 Nos working at a time and 01 No. standby) with all connected equipments and machineries as per Serial No 1 of Annexure 'A' to Particular Specifications] round the clock through out the month in three shifts (including Sundays and Holidays) by employing one operator cum AC machenic per shift of eight hours including carrying out routine maintenance and upkeeping the Installation / AC Plants in operation condition complete in all respects as specified and directed :- Location : Missar Mine Workshop at NAD (Trombay): (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs (iii) 3rd shift - 2200 hrs to 0600 hrs
Mannual Rescue and Operation Rescue of Central AC Plants [Installation consisting of AC Plant of direct expansion type 60 TR capacity having 03 Nos compressors each of 30 TR capacity (02 Nos working at a time and 01 No. standby) with all connected equipments and machineries as per Serial No 3 of Annexure 'A' to Particular Specifications] round the clock through out the month in three shifts (including Sundays and Holidays) by employing one operator cum AC machenic per shift of eight hours including carrying out routine maintenance and upkeeping the Installation / AC Plants in operation condition complete in all respects as specified and directed :- Location : EKM workshop: (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs (iii) 3rd shift - 2200 hrs to 0600 hrs
Mannual Rescue and Operation Rescue of Central AC Plants [Installation consisting of AC Plant of direct expansion type 30 TR capacity having 02 Nos compressors each of 30 TR capacity (01 No. working at a time and 01 No. standby) with all connected equipments and machineries as per Serial No 4 of Annexure 'A' to Particular Specifications] round the clock through out the month in three shifts (including Sundays and Holidays) by employing one operator cum AC machenic per shift of eight hours including carrying out routine maintenance and upkeeping the Installation / AC Plants in operation condition complete in all respects as specified and directed :- Location : P-78 Magzine & New Mine Workshop, P-35 at NAD Trombay: (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs (iii) 3rd shift - 2200 hrs to 0600 hrs Notes for Item No. 1.00 to 3.00: Quoted rates shall also be deemed to include the following elements:- (i) To provide uniform, tools & plants, safety means like glove etc to the employees and also alternative employee (reliever) for Manning and Operation of AC Plants/Installation so that the other employees can avail the facility of weekly leave etc. (ii) To keep the AC Plant Room & allied area in clean and tidy condition during the operation period. (iii) To carryout the routine maintenance, minor repairs, oiling, greasing and to rectify the minor defects to keep the plants / Installation in serviceable condition all as directed by the GE and Engineer-in-Charge. However, the major repairs, replacements, overhauling, gas charging, topping-up oil etc are not included in the scope of the above items. (iv) To keep necessary documentation duly signed by all the concerned. (v) To hand over the entire plant in serviceable condition at the time of completion. (vi) Contractor shall submit the details of payment of wages for staff employed through Aadhaar linked bank accounts for payment purpose.
Manual rescue and operation rescue of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Mine Wokshop Pump House The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Monoblock centrifugal Pumping set of capacity 10 HP-02 Sets
Manual rescue and operation rescue of water supply installation with all connected equipments, supply lines,Machineries and electric driven pump set of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 01 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Location : New CMT Complex Firefighting Pump House The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Jockey Pumping set of capacity 12.5 HP-01 Sets (ii) Operating Main Electric fire Pumping set of capacity 60 HP-01 Sets (iii) Operating Diesel Engine Pumping set of capacity 69 HP-01 Sets
Manning and operation of water supply installation with all connected equipments, supply lines ,Machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : WED Pump House
Manning and operation of water supply installation with all connected equipments, supply lines,Machineries and electric driven pump set of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 01 shifts, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : DSRV WED Firefighting Pump House NoteS for item No.4.00 to 7.00:- (a) Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractor from his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account. (b) Installation shall be manned including Saturdays, Sunday & Holiday. (c) Proper log sheets for running of the pump to be maintained. (d) Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge. (e) Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f) Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing. (g) The contractor shall be responsible to keep the water supply installation neat and clean on every day. (h) All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (i) Operator - @ Rs 2000 per operation shift per head. (ii) Valve man - @ Rs 1800/- per operation shift per head. (k) Contribution towards bonus EPF, ESIC the amount is payble only after submission of valid and authentic document in support of having paid the requisite amount to the employed labour.
Mannual rescue and operation rescue for following installations, with all connected equipments and machineries as detailed herein under with one operator / mechanic, operation in 03 shifts, including Sundays and holidays including routine maintenance checks, tests, etc and upkeeping the installation complete all as specified and as directed. Location : Thane NCN Bldg Shifts (i) 1st shift - 0600 to 1400hrs (ii) 2nd shift - 1400 to 2200hrs (iii) 3rd shift - 2200 to 0600hrs The details of operation of installations comprising the following items/machinery/fittings:- (i) Operating DG set 600KVA - 2 Nos (ii) Operating AC plant of capacity 11 TR (iii) Operating terrace fire pump set (iv) Operating water pump set Notes :- 1. Any malfunctioning noticed during the entire contract period on account of negligence of the operaters , the cost of Repair /replacement of defective parts shall be recovered from any dues from the contractor. Decision of the Eng - in Charge on this subject shall be final and binding 2. Quoted rates shall also be deemed to include the following elements:- (i) To provide uniform, tools & plants, safety means like glove etc to the employees and also alternative employee (reliever) for Manning and Operation of DG set, Pump sets & AC Plants/Installation so that the other employees can avail the facility of weekly leave etc. (ii) To keep the DG set room, AC Plant Room & allied area in clean and tidy condition during the operation period. (iii) To carryout the routine maintenance, minor repairs, oiling, greasing and to rectify the minor defects to keep the plants / Installation in serviceable condition all as directed by the GE and Engineer-in-Charge. However, the major repairs, replacements, overhauling, gas charging, topping-up oil etc are not included in the scope of the above items. (iv) To keep necessary documentation duly signed by all the concerned. (v) Proper log sheets for running of the pump to be maintained. (vi)Installation shall be manned including Saturdays, Sunday & Holiday. (vii) To hand over the entire plant in serviceable condition at the time of completion. (vii) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (a) Operator - @ Rs 2000 per operation shift per head.
Supply only refrigerant (R-22) gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON
Supply only refrigerant (R-407 C )gas as per requirement, complete all as specified and directed. Make : MAFRON/FLORON/ REFRON/ FREON.
Supply only compressor oil as per requirement, complete all specified and directed. Make : Servo, HP, BP, Sheetal N-68, Freezol 36.
Taking down AC Plant compressor reciprocating type model SMC- 8-100 of ACCEL Make by dismantling complete assembly after pumping down refrigerant R-22,overhauling the compressor including replacement of unserviceable spares, also including machining of crank shaft bearing, polishing, replacing of gaskets packing, reassembly and recharging of pumped down Refrigerant, also charging of additional refrigerant upto the required pressure & topping up if required to maintain the required standing charged pressure of compressor oil, testing for smooth functioning etc, complete all as specified and directed. Location : P - 35, NAD (Note: Cost of all the elements (material cost as well as labour cost) for making the compressors completely functional except the following shall be deemed to be included in the quoted rates : (a) Supply only spares (b) Supply only additonal refrigerant required for recharging of pumped down refrigerant, if required. (c) Supply only compressor oil for topping up, if required.
Supply only following spares for compressor reciprocating model SMC- 8-100, Make : ACCEL :
Crank shaft duly remetalised, grinded, polished and made to size to match with the existing, Cat No. F -7803
Piston Cat No. V5124A
Piston Oil rings Cat No.V5485
Main sealing bearing (Set of two) Cat No. F-7276
Liner assembly Cat No. F-7167
Oil pump assembly Cat No. F-6501
Rocker arm Cat No. F-7166
Loader/unloader spring Lock Cat No. F-7277
Piston sleeves bushing with collar, Cat No. F-7165
Suction valve reeds Cat No. F-8162
Discharge valve reeds Cat No. F-6504
Oil filter Cat No. F-7796
Suction Filter Cat No. F-7167
Oil pressure regulating valve Cat No. F-6507
Connecting rod bearing Cat No. F-7164
Gasket set of make Neopene or equivalent as appoved by the GE
Compressor safety valve Cat No. F-7278
Shaft seal assembly, Cat No. F-7646 Note : The quantity of item Nos 13.00 to 13.18 shall be operated only to the extent required replacement for compressors under item No. 13.00 here-in-before. Unless othewise specified in the BOQ, these shall be of make ACCEL & of mentioned Cat No in the BOQ and shall be suitable for the compressors under item No 13.00 all as directed and approved by the GE.
Replacement of unserviceable MS pipe, heavy grade of following sizes (condenser water tubing from the cooling tower area) including provision of all fittings, welding and connected works as required for smooth functioning of AC Plants, complete all as specified and directed, Make : TATA/JINDAL :-
150mm bore
100 mm bore
M & L for replacement of unserviceable Cooling Tower accessories i.e. water inlet/out pipe and filter, fanblade, fan bulb, fan shaft, GI bolts, nuts, MS frame and ladder etc complete and refitting old PVC fills (serviceable qty shall be reused to the extent available) after cleaning with diluted HCL solution suitable for the cooling tower of 60 TR of FRP Basin, complete all as specified and directed. Note : Extra PVC fills required to complete the job shall only be measured and paid separately as supply only to the extent required and ordered and cost of all the other elements to make the cooling towers completely functional shall be deemed to be included in the quoted rates.
Repair/installation 60 to 78 TR chiller after removing suction / discharge pipe line of gas / water transporting the chiller to workshop, opening both and flange of chiller, cleaning the shell side of chiller and copper tubes with fresh water, pressure testing with water, keeping chiller 24 hrs of pre testing, chocked copper tubes 3/4" 120 nos removed the existing chiller after brazing / welding closing the both end flange with new gasket after changing the nuts and bolts ,pressure testing carried out after changing the tubes, transporting the chiller to site complete with new nuts & bolts in orginal position connecting suction / discharge gas line by welding & brazing, vaccumising the system, pressure testing N2 gas if no leakage found, gas charging with required R22 Insulating the chiller nitrile rubber sheet can chiller body and suction / discharge gas pipeline in orginal position testing the system for smooth functioning all as specified & directed.
Supply and fix in repairs install, testing and commissioning of double skin, floor mounted, Air handling unit 6 rows deep cooling coil of Suitable capacity , 50TSP and comprising of the following : (i) 6 Row Cooling coils of copper tube with aluminium fins. (ii) Prefilter. (iii) Blower for AHU with suitable motor, TEFC scroll case induction motor for operation on 415 volts, 3 phase, AC supply with suitable starters with overload protection and single phase preventors with V belt and guard. (iv) Insulation of AHU as specified. Make : Zeco or equivalant Voltas/Blue star
Material and labour for repairs to Microprocessor of 30 TR Capacity AC Plant chiller unit including replacing diods, transistors and wiring etc all as specified and directed.
S & F in replacement contactor type ML-2.0, 415Volt, 50Hz for star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed, Make L & T/ Marline - Garline/ SIEMENS/ Schneider
S & F in replacement contactor type ML- 3, 415Volt, 50Hzfor star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed. Make L & T/ Marline - Garline/ SIEMENS/Schneider
S & F in replacement contactor type LCD-150, 415Volt, 50Hz for star delta starter for motor of compressor, water pump and chiller pump etc. complete all as specified and directed. Make L & T/ Marline - Garline/ SIEMENS/Schneider
Supply only PVC fills of size 600mm x 150mm x 150mm complete all as specified and directed.
Supply only PVC fills of size 600mm x 300mm x 150mm complete all as specified and directed.
Supply, Fabrication, Installation, Testing and Commissioning of ducting for supply/Return made out of GI steel metal 22 gauge, Zinc coated complete with all standard accessories, flanges, G I Hardware, Self Adhesive elastomeric foam gasket, support etc as per IS-655, complete all as specified and directed.
M&L for duct insulation (50mm thick) with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, as specified and including provision of the followings : (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completely free of miss-scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) M&L for securing the insulation with and inculding mechanically fastened nylon / steel straps of size 50mm wide at maximum intervals of 1.2 metre.
Supply and fixing AHU filters 10.0 micron 98% efficiency of existing suitable size for AHU after removing old unserviceable AHU filters.
Taking down the defective flexible cable PVC insulated multistranded copper / Aluminium conductor of 16 Sqmm 3 Core and supply and fix new flexible PVC insulated multistranded copper conductor of 1100 volts grade complete.
Taking down the defective flexible cable PVC insulated multistranded copper / Aluminium conductor of 1.5 Sqmm 6 Core and supply and fix new flexible PVC insulated multistranded copper conductor of 1100 volts grade complete.
M & L for dismantling and repair/servicing /overhauling of split cage Centrifugal pump set by opening casing cover, remetalling of worn out shaft and replacing of worn out bearing both ends, nuts, bolts, gasket, gland packing, rubber coupling and reinstalling in same position including testing complete all as specified and directed by engr- in - charge for the Pump set 167 HP.
All as per item No 29.00 above but Pump set 60 HP
All as per item No 29.00 above but Pump set 15 HP
M & L for dismantling of monoblock pump for repair/ servicing by opening both end cover and replace wornout bearing of existing size, taking out shaft and impeller and remetalling worn out shaft thread, including replacement of nuts bolts, gland packing etc and re installing in same position complete including testing pump capacity 10 HP.
Supply and fabricate valve chamber covers made out of suitable size as directed with MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed.
Supply and fix in repair Contactor 3-Pole of suitable capacity as per ground requirement for pump set 5HP ,complete all as specified and directed. Make:-Havells/schneider/L&T
All as per item No 34.00 above but Pump set 10HP
All as per item No 34.00 above but Pump set 20HP
All as per item No 34.00 above but Pump set 40HP
Taking up or down steel tubing and connections including cleaning and setting aside for refixing or as schedule of credit, etc complete all as specified and as directed for the 25mm bore pipes including necessary staging/scaffolding as required complete all as specified and directed.
All as per item No 38.00 above but 40mm bore
All as per item No 38.00 above but 50mm bore
All as per item No 38.00 above but 80mm bore
Supply, lay/fix, connect and testing in repair steel water tubing of 25 mm dia, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures, and fixed to wall/ceiling or laid in trenches/floors complete all as specified and directed.
All as per above item No. 42.00 but of size 40 mm dia
All as per above item No. 42.00 but of size 50 mm dia
All as per above item No. 42.00 but of size 80 mm dia
S & F in repair cast iron Ball Foot valve 80mm flange type model B-05 (N) conforming to IS with MS nuts bolts, washer, rubber gasket etc., any pattern as approved including taking out/ dismantling old unserviceable one and testing complete all as specified and as directed. Make : KIRLOSKAR/UPADHYAYA/LEADER/NORMEX/VENUS.
All as per above item No. 46.00 but of size 100 mm dia
All as per above item No. 46.00 but of size 150 mm dia
M&L for PCC foundation 1:2:4 as per site requirement,including form work complete all as specified and directed by engineer-in-charge.
Supply and fix in replacement ladder height 12 feet max, steps on every 01 feet made of angle iron of size upto 65x65x5 mm thick for sump/ static water tank including taking down old rusted iron ladder complete all as specified and directed.
Collecting water sample in clean bottle from location as directed for testing of physical test, chemical test, microbiological test as per IS-10500-1991 from NABL approved chemical laboratory and submitting test report complete.
Supply and fix in repairs unservicable water pressure gauge 4" dia with tube to match with the existing for range 0 to 14 kgs rating complete all as specified and directed.
Supply and fix in repairs unservicable water pressure gauge 4" dia with tube to match with the existing for range 0 to 21 kgs rating complete all as specified and directed.
M&L for rewinding of electric motor 3 phase 50 Hz 415 volt for 15 HP capacity complete all as directed and specified. (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc., (b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing on load. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/nut, bolt washer. NOTE: Quoted rates shall be deemed to include one year warranty for motors after rewinding and commissioning.
M & L for valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including dosmantling the existing valve chamber complete all as specified and directed by Engr In Charge.
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of previously untreated surfaces of steel and iron exc 10 cm width or girth.
Supply, fixing, jointing and testing of 80 mm, CI Sluice Valve heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed . Make : Kirloskar / leader /Kartar/Racold
All as per item No. 57.00 above but 100 mm bore
All as per item No. 57.00 above but 150 mm bore
Supply, fixing, jointing and testing of 100mm, CI Non return valve sluice tpe heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed . Make : Kirloskar / leader /Kartar/Racold
Supply, fixing, jointing and testing of 150mm, CI Non return valve sluice tpe heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed . Make : Kirloskar / leader /Kartar/Racold
M&L for prepration of exposed surface of centrfugal pumping set of capacity 20 HP to 60 HP with and including suction and delivery mains 80/100 mm dia GI pipe,NRV upto 10 mtrs length removing rusted scale from body cleaning surface area and applying one coat of red oxide primer and two coats of syenthetic enamel paint of approved make writing MES NO,SL NO,Flow of water on pumping set all as specifed and directed by Engineer-in-charge.
Maint/Cleaning of Pump house stations inside and out side area and removing of creepers and vegetation raised along with water supply installation including surface dressing around the E/M installation not less then 3 mtr from out side fencing and removing all the waste material from site and Chemical spray inside and out side area of Pump House Note:- T & P will be arreanged by contractor
M & L for disconnecting from supply and shifting of LT panel Boards from one place to another place and preparation of old painted / unpainted surfaces of any size of panels, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying one coat of synthetic enamel paint over a coat of red oxide primer for panel with new danger sign board made from mild steel, thickness not less than 1.6mm and size of 200 x 150 mm, vitreous enamelled white, with letters, figures and the conventional skull and cross bones in signal red colour on the front side and rear side of the plate also be enamelled conforming to IS- 2251-1982, complete all as specified and as directed by Engineer-In-Charge.
Repairs of existing LT panels boards including removing of burnt cable portion/carbon deposit worn out cable lugs/nuts bolts/insulation sleaves/insulators cable glands,internal wiring/Repair/Replacement of hinges for proper opening & closing and testing for smooth functioning of the panel board and marking the warning symbol ,viterous enamelled white ,with letters ,figures and conventional skull and bones in single red colour and fixed on panels including painting with one coat of syenthetic enemal paint inside and outside of exixting colour all as directed by Engr-in-charge of following sizes:-
(a).Upto 0.9 x 0.8 x 0.3 mtr.
(b). Upto 1.05x1.5x0.3 mtr.
(c) . Upto 2.0 x 1.5 x 0.3 mtr
M & L in repairs of insulating mats 2.5mm thick made of elastometer (a generic term that includes rubbers, latex and elastometric compounds that may be natural or synthetic or a mixture or a combination of both) for use as floor covering for the protection of workers on ac and dc installations with the system voltages up to 11 KV ac and 240 V dc and as per cl 5 of IS 15652 latest class B Cat II of size 1mX2m including taking out old u/s insulating mats complete with relevant test reports and fixing on floor with suitable adhesives all as specified and as directed. Note : The mat should be permanently pasted with the held of suitable adhesive/resin. All joints and corners shall be filled/covered with insulating material of matching colour. Matching colour and matching designed tapes should be used to maintain an aesthetic look of the installation.
M&L danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter,figures and conventional skull and bones in single red colour & fixed with MS clamps,bolts,nuts and of size 25x20 cm for HT 11/22 KV including taking out old unserviceable rusted out danger plates.
All as per item No.67.00 above but for LT size 20x15 cm.
M& L for relaying / rerouting of LT cables connect, test and commissioning of LT under ground cable PVC insulated PVC sheathed armoured with multistranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands,lugs and suitable size of MS saddle clips(where ever cable laid in ceilings/walls without cable duct) all as directed by the Engr-in-Charge for the following :- Note:- (I) Excavation,sand cushioning,brick will be measured and paid separtely
(a) 10 sqmm to 25 Sqmm,2/3.5/4 core
(b). 35 Sqmm to 70 Sqmm,3.5 /4 core.
(c). 95 Sqmm to 120 Sqmm,3.5 /4 core.
(c). 240 Sqmm to 300 Sqmm,3.5 /4 core.
M&L for straight through joint epoxy type for UG cable including joint kit for making joint suitable for the following size:-
(a) 10 sqmm to 25 Sqmm,2/3.5/4 core
(b). 35 Sqmm to 70 Sqmm,3.5 /4 core.
(c). 95 Sqmm to 120 Sqmm,3.5 /4 core.
(c). 240 Sqmm to 300 Sqmm,3.5 /4 core.
Supply and Laying in repairs passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make :- FINOLEX/ KEI/ POLYCAB/HAVELLS
Supply and Laying in repairs passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5core including necessary connection and providing cable lugs as required all as specified. Make :- FINOLEX/ KEI/ POLYCAB/HAVELLS
Supply and Laying in repairs passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make :- FINOLEX/ KEI/ POLYCAB/HAVELLS
Supply and Laying in repairs passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make :- FINOLEX/ KEI/ POLYCAB/HAVELLS
Material and labour in repairs for earth continuity conductor or main earthing lead fixed to wall with suitable insulator on batten or recess or chasis or buried in ground or drawn in conduit / pipe or any other indicated situation for and connecting to test point terminal block with GI strip of size 25 x 4 mm including taking out old u/s earth continuity conductor complete, all as specified and directed.
Supply and fixing in replacement for GI protection pipe light grade for cable protection incl all fittings laid in trenches or fixed on pole,including making good the disturbed surfaces all as specified and directed for following sizes :-
80 mm dia
50 mm dia
supply and fix in repair fully automatic star delta starter suitable for eletrical motor 10 HP, Model MK1 FASD of L& T Make, CAT Pat: SS96254 or equivalent to C & S / Schneider / CROMPTON
supply and fix in repair fully automatic star delta starter suitable for eletrical motor 25 HP, Model MK1 FASD of L& T Make, CAT Pat: SS96254 or equivalent to C & S / Schneider / CROMPTON
supply and fix in repair fully automatic star delta starter suitable for eletrical motor eletrical motor 40 HP, Model MK1 FASD of L& T Make, CAT Pat: SS94366 or equivalent to C & S / Schneider / CROMPTON
Comprehensive Repairs and maintenance of Fire alarm system installed at NAD Trombay, the system comprises of main Fire alaram Control Panel with battery back up, Repeter panel , Motor operated Sirems, Manual call Points installed at various location complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at 31 WEU Thane. The system comprises main Fire alaram Control Panel with battery back up, Manual Call Point (MCP), Electronic Hooter, Heat Cum Smoke Detector, Remote Response Indicators, installed at various locations complete,
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Naval Station Thane. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at NCN Thane. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at TS Mahul. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at DSRV. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at T7 CMT Complex The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Single Officer accn, NOFRA. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Relese Sailor Accn, Tanaji. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete.
Comprehensive Repairs and maintenance of Fire alarm system inslalled at NSD Sewri. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators, installed at various locations complete. Note for item ser No 80.00 to 89.00 : a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommend the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alaram panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. c) Testing the fire alram system including checking of each MCP and maintining serviceablity records on monthly basis. d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning.
Supply & fixing in repairs flame proof manual call point (MCP) Housing with 24 Volt addressable MCP card and hammer, including making addition/alternation to existing suppors of MCP. Make - ANG FPA or , PCD Fire System, Safetech, Zicom, Apollo.
Supply & fixing in repairs Switch Mode Power supply operating at input volatage range 180 to 270 Volts and having maximum out put volatage of 28.5. Make - Proxymon/Omron
Supply & fixing in repairs maintenance free 12 Volts 15 AH battery suitable for fire alaram panel Make - Exide, Amron,Amco
Supply & fixing in repairs maintenance free 12 Volts 26 AH battery suitable for fire alaram panel Make - Exide, Amron,Amco
M & L for Removing of burnt electric motor 1 HP to 3 HP, 440 Volts of fire alaram siren after dismantling of all electrical connections & transporting from site to workshop, rewinding of electric motor with super enameled copper wire after removing of old burnt coil, replacing of bearing, cleaning of slots properly, heating in heat chamber after varnishing and testing at site and including scrapping the old paint and applying one coat of red oxide primer and applying two coat of synethetic enamel paint. all as directed by Engineer-in-Charge. Note :- Cost of insulation paper, varnish and any nuts, bolts and lugs required for the job shall be deemed to be included in the quoted rate
Supply & fixing in repairs Detectors complying with and type certified to EN-45 type multisensor detector with heat and smoke combination photo electirc / optical with base with self built intelligence as per IS - 11360 complete. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,
Supply & fixing in repairs DOLstarter 3 Phase 440 volts suitable for 2 HP fire alaram siren motor Make “Siemens / L&T /ABB ” as existing in panel board.
Supply & fixing in repairs response indicator complete with cable connection testing and commissioning all as specified and directed by Engr-in-Charge. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,
Supply & fixing in repairs Electronic hooter 24 Volt DC complete for fire alaram system complete with acessories all as directe by engineer-in charge Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD
Supply & fixing in repairs conventional manual call point with pill box complete with hammer, chan and all fixtures Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in soft / lose soil
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge.
M&L for sand cushioning by spreading in trenches stone curshed sand by gently by punning down manually as in cable protection all as specified and as directed by EIC.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
M & l for taking down of old sables & Supply & lay armoured XLPE Insulated 1.5 Sqmm 4 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. Make - Poly Cab/Havells/Plaza
M & l for taking down of old sables & Supply & lay armoured XLPE Insulated 1.5 Sqmm 2 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. Make - Poly Cab/Havells/Plaza
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
M & L for TMT bars of Fe-500 D grade conforming to is:1786, 10 mm dia & over, including cutting to length, bent to shape equired, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8 mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130 mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make :- Bajaj
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
Supply & fix in repair 3 core 1.5 Sqmm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt cable for interconnection of cable looping box to Street Light Fitting all as Directed.
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volt grade, cross sectional area 16 Sqmm, 4 Core Conforming to IS-7098 (Part-II)-1985 complete .
M&L for cutting existing road/hard, dense soil not exc 45x60 cm in wide & depth getting out excavated material for laying GI tube returning filling & well ramming watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed
S & F in replacement of security light fitting/Building security light LED type 60 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO.
sapana enterprises (BID ID -3169402)
shakti engineering and electrical works (BID ID -3173290)
M/s Vijay Airconditioning Pvt Ltd (BID ID -3168943)
Veer High Tech Solution (BID ID -3172987)
Darpan Construction (BID ID -3169146)
BRITE INDUSTRIES (BID ID -3169706)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .