Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹29.7 L+₹1.6 L (5.67%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹30.5 L+₹2.4 L (8.72%)Rejected-Finance 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹30.6 L+₹2.5 L (9.01%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹31.9 L+₹3.8 L (13.5%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹33.8 L
EMD Value
₹67,600
Closing Date
9 Jun 2020, 6:00 pmClosed
GE NDA KHADKWASLA
GE NDA KHADKWASLA
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION INCLUDING FANS AND GEYSERS AT JCOS AND OR AND FOLLOWERS MD ACCN INCLUDING OTMS AT ZONE C AT NDA KHADAKWASLA
2020_MES_344904_1
GE (K) 03 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADKWASLA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
₹67,600
Yes
6 Jul 2020
14 May 2020
11 Jun 2020
15 May 2020
9 Jun 2020
27 May 2020
16 May 2020 - 26 May 2020
Amount
Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring, switch, sockets etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of switch, socket, lamp holder, connector, connection wire etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. (iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 50/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at JCOs,ORs,Followers and OTM Accn area. (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the S&F in replacement of items here-in-below.
Supply only following spares for light fittings of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- Spring loaded G13 side holders (set of 2) suitable for 18/20/36 watt and LED fitting
Supply only PVC Angle type lamp holders retrofit type suitable
Supply only modular step type fan regulator 120W, 2 module Make- Vinay/Anchor Roma/Legrand
Supply only modular switch piano type 6 amps one way one module Make - Vinay/ Anchor/Roma/Legrand
Supply only modular switch piano type 16 amps one way one module Make - Vinay/ Anchor/Roma/Legrand
Supply only modular Socket, 6A - 2/3 pin 2 module Make - Vinay/Anchor Roma
Supply only modular Socket, 6/16A - 2/3 pin 2 module Make - Vinay/Anchor Roma
Supply only Switch socket combination 5/6 Amps flush mounted 3 pin multi purpose all as specified. (Make:Anchor/Vinay)
Supply only socket combination 5/15 Amps flush mounted 3/5 pin multi purpose all as specified. (Make:Anchor/Vinay)
Supply only switch piano flush type 5 Amps SP one way all as specified. (Make:-Anchor/Vinay)
Supply only bell push, flush type 5 Amps all as specified and directed. (Make:-Anchor / Vinay)
Supply only fan regulator electronic step type suitable for 1200/1400 mm sweep fan as per the sample provided by the Site-in-charge. (Make:Anchor/Vinay)
Supply only ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body.
Supply only door bell AC 230 volts single phase ding dong type all as specified and directed. Make:Anchor/Vinay
S&F in replacement of 18/20watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified .Make:Luker Cat No LT5M20 or equivalent in Polycab/Philips
Supply and fix 18/20 watt of LED retrofit tube light with high efficiency suited for installation in existing T8 tube light with G13 lamp holders all as specified and directed by Engr-in-charge. Make:Polycab Cat No LTU0101005 or equivalent in Philips/Luker
S&F in replacement 1x18/20W,230V surface and wall mounted batten suitable for installing LED Tube including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified . Make:Philips or equivalent in Polycab/Luker
S&F in replacement 1x 10watt,230V surface and wall mounted LED batten, including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified . Make - Wipro or equivalent in Philips/Luker
Supply and Fixing in replacement of 150 watt integral SMD LED Highbay luminaire with aluminium reflector light fitting incl with inbuilt electronic drivers ,necessary hanging arrangements as per site requirement all as specified and directed by Engr-in - Charge Make Havells/ Luker/Polycab. Note: 1. Ladders /Cranes shall be used and will be provided by contractor for dismantling /fixing of light fittings at roof and cost for the same is deemed to be included.
S&F factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified (Make/Model of VTPN DB : Legrand/L&T/Siemens) Note:MCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site. Make: Havells/Legrand/C&S
S&F in replacement MCB DB 04 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site. Make: Havells/Legrand/C&S
S&F in replacement MCB DB 02 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site. Make: Havells/Legrand/C&S
S&F MCCB with rating of 100Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals all as speicified.
Supply and fix in replacement of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
Supply and fix in replacement of C Curve MCB SPN 6-32 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
S&F MCB TPN 40- 63 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces all as directed
M&L point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC conduit/PVC casing capping double lock type ISI marked not less than 19 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 1.0 sq mm copper conductor as earth wire to common earth dolly including PVC box suitable for switches, sockets, fan regulator etc for following :- One light/Fan point controlled by one way switch 6 Amps 240 volts
Ditto all as per item No. 30 above but one 3 pin 6 Amps socket out let point on independent board.
Ditto all as per item No. 30 above but one 3 pin 6 Amps socket out let point on same board.
Ditto all as per item No. 30 above but one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete as directed.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/Conduit medium grade not less than 19 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (Two runs of 6 Sqmm cable with 01run of 06 Sqm m earth wire along with casing caping shall be measured as one RM)
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 19mm complete with accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04 Sqmm cable with 01run of 04 Sqmm earth wire along with casing caping shall be measured as one RM)
M&L point wiring with 2.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 19 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FR cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box suitable for 15 Amps socket and switch outlet power point independent circuit
M&L for secruing loose wiring and repair to point wiring with necessary rigid non metalic PVC casing caping/Conduit double lock type ISI marked of size not less than 19mm inclusive all accessories complete as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed. Note : 1.Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as S&F in replacement of. Note No (iii) to (vi) below Item No 1 of this schedule are equally applicable to this item too.
Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan. Make:Tibcon/Epcos
Supply only capacitor of 4 mfd for air circulator/exhaust fan. Make:Tibcon/Epcos
Supply only of bearing No.6201/6202/6203 or any other No. matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan.Make:SKF
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor rewinding with super enarneled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position all as directed. Celling fan of size 1200 sweep.
Ditto all as per item No 43 above but exhaust fan of 300 mm sweep.
M&L for painting the ceiling fan of any sweep with two coats of synthentic enamel paint by rubbing/removing the old paint carefully without any damage to the fan or fan blades all as specified.
Ditto all as per item No 45 above but exhaust fan of size 12" (300 mm)sweep
Dismantling and removing rusted louvers suitable for any sweep exhaust fan supply and fix MS louvers duly painted gray coloured suitable for any sweep heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as directed.
Supply and fixing in replacment alluminum fan blades sutable for heavy duty exhaust fan of any sweep as per the sample given by the site-in-charge
Supply and fix in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB single pole 10 Amps, 240 volts complete with all accessaries etc all as directed by Engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified
S&F in replacement LED building security light fiitting 15W,IP-65 protection made up of die cast alluminium housing with high power LED as lighting soource and lens complete fixing with bracket of adequate length, incl electrical connection from connector to light fitting. and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed by Engr-in-charge. Make Polycab/Luker/Havells
Supplying and fixing 1100 volts grade heavy duty cable 4 Sqmm PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
S&F ceiling fan of sweep 1200mm,240volts, of not less than 3 star BEE rating milk white coloured connecting up with twin core 1.0 Sqmm cable from ceiling rose including required length of down rod as per the site requirement all as specified. Make:Orient/Havells/Crompton Greaves
S&F high speed wall mounted fan of sweep 400 mm,,Full copper motor,auto thermal overload protection,compact style and powder coated gurads & pull cord switch for speed regulation and oscillation control including connectng up the power cord to the socket and necessary fixing accessories all as specified and directed.Make:Crompton or equivalent in Havells/Orient
Supply and fix in replacement NRV valve of size 15mm dia of Brass complete all as specified and directed.
Disconnecting and taking down existing userviceable geyser of 25 ltrs capacity, taking it to civil workshop for repairing. Opening the geyser and dismanting all parts and taking out inner tank/container, removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material . Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled paint and re- fixing to original place all as directed
M&L in replacement thermostat 0-85ºC suitable for geyser of 25 ltrs capacity.
M&L in replacement heating element of capacity 1.5 KW of any type and shape suitable for 25 ltrs capacity geysers of any brand / make.
M&L in replacement flow unit (inner pipe assembly) suitable for geyser of 25 ltrs capacity vertical type including rubber ring/gasket.
Supply and fix in replacement metallic flexible hot water connection 600 mm long including necessary washers suitable for geysers of 25 ltr capacity complete all as specified and directed.
Supply & fix neon lamp indicator square/round type after taking out old incl taking down old one.
Supply & Fix in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm as in connection cord of the geyser, Make : Polycab / Havells /Finolex
Supply and fix in replacement plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cord.
Supply and fix in replacement metal clad plug top 3 pin,10Amps, 230 volts, ISI marked heavy duty for geyser connection cord.
Fixing only the 25L Geyser and connecting up including with suitable fastner as per ground requirement complete all as specified and directed. (Note:Geyser will be issued under Sch 'B' store free for fixing only)
M&L in replacement heating element of capacity 3 KW,ISI marked of any type and shape suitable for solar water heater system of existing manufacturer brand / make.
Fixing only the ceiling fan of 1200 mm sweep and connecting up including provision of twin core flexible copper cable from ceiling rose or connector to fan all as specified. (Note:Ceiling fan will be issued under Sch 'B' store free for fixing only)
S& F PVC unbreakable surface boxes suitable for 2x5Amp switch socket combined. Make - Press Fit
S& F PVC unbreakable surface boxes of size suitable for 01x 15Amp switch socket combined. Make - Press Fit
S& F PVC unbreakable surface boxes of size suitable for 04x05Amp switch socket combined. Make - Press Fit
Supply and fixing in replacement of metal body ventilation fan of 225/230 mm sweep inclduing replacing the plywood as per the site requirement. Make Crompton, Orient or Havells
S&F electrical meter box compartmentalized design suitable for 4 x energy meter and 4 x Eight way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For NCO Qtrs) (Note: quoted rate shall deemed to including for disconnecting existing circuits from DB's and energy meter and same has been refixed in new meter box)
S&F electrical meter box compartmentalized design suitable for 1x energy meter and 1 x Four way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For JCO Qtrs) (Note: quoted rate shall deemed to including for disconnecting existing circuits from DB's and energy meter and same has been refixed in new meter box)
M&L for repalcing the down rod of ceiling fans with 5 feet GI ceiling fan hanging down rod with necessary clamp accessories all as directed.
Sneha Aircool
R. K. Industrial Fabricators
SONU ENTERPRISES
M/S SHREE CONSTRUCTIONS
Sparkh Electricals & Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .