Loading…
Loading…
Tender Value
₹68.3 L
EMD Value
₹1.4 L
Closing Date
13 May 2025, 3:00 pmClosed
Signal and Telecommunication work in connection with requirement of modifications in circuit for removing operational constraints at Pune GIT Station of Pune Division.
CR-PA-SNT-WKS-S-2025-04
CR-PA-SNT-WKS-S-2025-04
Open
Works - General
6 Months
Pune, Maharashtra
₹0
₹1.4 L
15 Apr 2025
15 Apr 2025
Item- 1 Part-I : Supply Portion (SOR Items)
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply of PVC Indoor Cable 1x60x0.6mm dia Kilometre 0.50 345927.52 172963.76
Colour coding of insulation of inner core shall
be in six colour viz Blue, Red, Grey, Green,
Brown & Black conforming to IRS 76/89
(Amd.3) or latest. (Inspection by Consignee)
2 2 Supply of PVC Indoor Cable 1x40x0.6mm dia Kilometre 0.50 226936.58 113468.29
Colour coding of insulation of inner core shall
be in eight colour viz Blue, Red, Grey, Green,
Brown, Black, Yellow & White conforming to
IRS 76/89 or latest. (Inspection by
PUNE DIVISION-S AND T/CENTRAL RLY
3 3 Supply of Indoor Jumper Wire of various Kilometre 5.00 9745.11 48725.55
colour as per Railways standard practice of
type ATC 1 x 0.6 mm dia.conforming to IRS
76/89 (Amd.3) or latest. (Inspection by
4 4 Supply of Indoor Jumper Wire ATC 1 x 1 mm Kilometre 0.20 15088.84 3017.77
dia. conforming to IRS 76/89 (Amd.3) or
latest. (Inspection by Consignee)
5 5 Supply of wire 16/0.2 (Blue, Red, Grey, Kilometre 1.00 7415.17 7415.17
yellow, Brown, Black, White as per site
engineer instruction) finolex/polycab/delton
make. IRS S-76/89 (Amd.3), BS: 4808 Part-2.
Wire to be procured from RDSO approved
vender. (Inspection by Consignee)
6 6 Supply of low maintenance Lead Acid Numbers 15.00 2411.43 36171.45
Secondary Cells 2V 80 AH as per spec. IRS
88/2004 with latest amendments. (Inspection
7 7 Supply of Rubber Mat 5mm thick for use in Kg 50.00 149.03 7451.50
signalling installation. (Inspection by
8 8 Relay base plate complete with amphanols, Numbers 10.00 717.40 7174.00
code pins, fixing screws etc.suitable for Metal
to Metal K-50 mini groups/ECRs of Siemens
Make or functional equivalent of other
makes. Note : Relay base plates, are to be
procured from Relay manufacturer(OEM).
Manufacturer's Certificate for procurement
and guarantee in this regard should be
furnished. The payment to be released only
after Manufacturer's Certificate is submitted.
(Inspection by Consignee)
9 9 Supply of Shunt Signal Group Siemens make Numbers 2.00 66131.03 132262.06
[No. A-RT-RG-A065] or functional equivalent
without base plates (suitable for LED Signal).
(Inspection by RDSO)
10 10 Supply of Route Group Siemens Make ( Numbers 2.00 76359.35 152718.70
No.RSSK 31/0002) or functional equivalent
without base plates. (Inspection by RDSO)
11 11 Supply of Time Element Relay (Clock work Numbers 5.00 8920.58 44602.90
type) AG timer Siemens Make (No RSSK
30/0052) or GIC make or functional
equivalent. (Inspection by Consignee)
12 12 Supply of Plug In type Relay Metal to Metal Numbers 10.00 7021.16 70211.60
t y p e neutral relay mini groups (Non AC
I m m u n i s e d ) Siemens make (No. RSSK
30/0011) (Ref. IRS:S46/74 with Amd. 1 &
firms specification) or functional equivalent
without base plates.Contact configuration
5F/3B or 6F/2B or 4F/4B to be specified by
Engineer incharge. (Inspection by RDSO)
13 13 Supply of Plug In type Relay Metal to Metal Numbers 10.00 8538.67 85386.70
t y p e neutral relay mini groups (AC
Immunised-1) Siemens make (No. RSSK
30/0078-1) (Ref. IRS:S46/74 with Amd. 1 &
firms specification).or functional equivalent
without base plates.Contact configuration
5F/3B or 6F/2B or 4F/4B to be specified by
Engineer incharge. (Inspection by RDSO)
14 14 Supply of Plug In type Relay Interlocked Numbers 10.00 8016.55 80165.50
Siemens make (No. RSSK 30/0012) or
functional equivalant (Ref. IRS:S46/74 with
Amd. 1 & firms specification). Contact
cofiguration 4F/4B. (Inspection by RDSO)
PUNE DIVISION-S AND T/CENTRAL RLY
15 15 Supply of QNA1 AC immunised relay, 8F-8B, Numbers 5.00 4432.13 22160.65
24 VDC along with plug board, retaining clip
and connectors confirming to BRS : 931A,
IRS:S60, IRS:S34 & IRS:S23 (Inspection by
16 16 Supply of QSPA1 relay, 24VDC, slow to pick Numbers 5.00 5079.38 25396.90
up, 8F-4B, along with plug board, retaining
clip and connectors conforming to BRS:933A,
IRS : S60, IRS:S34 & IRS:S23 (Inspection by
17 17 Supply of QTA2 AC immunised track relay, 9 Numbers 5.00 4440.73 22203.65
Ohm, 2F.1B, along with plug board, retaining
clip and connectors conforming to BRS:939A,
966 & Appendix F2, IRS:S34 & IRS:S23
(Inspection by RDSO)
18 18 Supply of QBAT track Relay, AC immunised, Numbers 5.00 7597.66 37988.30
2F-2B contacts, 9 ohms. complete with plug
board, retaining clip & connectors as per
RDSO / SPN/84 Ver 2.0 or latest. (Inspection
19 19 Supply of Domino units with cover plate as Numbers 10.00 1719.95 17199.50
per approved panel diagram, each of size 54
x 34mm completely wired up similar to
Siemens make. Each domino units should
have all the 15 contact terminals wired up.
(Inspection by Consignee)
20 20 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 91.95 4597.50
IRS S:78-92 (a) With holder 1.6 A (System,
Rapid or Malnad make). (Inspection by
21 21 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 88.80 4440.00
IRS S:78-92 (b) With holder 0.6 A (System,
Rapid or Malnad make). (Inspection by
22 22 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 311.32 15566.00
IRS S:78-92 (c) With holder 6 A/10A ( D-Type
Bharat Linder, L&T or HEVELLS Make).
(Inspection by Consignee)
23 23 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 26.48 1324.00
IRS S:78-92 (d) Without holder 1.6 A (System,
Rapid or Malnad Make). (Inspection by
24 24 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 26.48 1324.00
IRS S:78-92 (e) Without holder 0.6 A (System,
Rapid or Malnad Make). (Inspection by
25 25 Supply of INDICATIVE TYPE OF FUSE INSERTS. Numbers 50.00 110.11 5505.50
IRS S:78-92 (f) Without holder 6A/10A (D-
type Bharat Linder, L&T or HEVELLS Make).
(Inspection by Consignee)
26 26 Resin cored wire as per specification No. Kg 50.00 1441.09 72054.50
IS:1921-1975 with Alloying element
percentage as 63% SN (Tin) and / 37% Pb
(Lead) with percentage of various impurities
not exceeding the values Sb (Antimony) 0.2%
maximum , Cu (Copper) 0.1% maximum, As
(Arsenic) 0.05% maximum, Fe (Iron) 0.02%
maximum & other impurities mainly Al, Zn &
Cd shall be limited. The flux shall be free
from corrosive action as per clause 5.2 & flux
percentage may be used as per requirement.
(Inspection by Consignee)
27 27 Lacing thread rolls, black, wax coated (100 Numbers 100.00 76.11 7611.00
mtrs). (Inspection by Consignee)
28 28 Supply of Shunt Signal Post with Base (GI Numbers 2.00 3119.98 6239.96
Pipe of 80 mm Dia of min. 1 meter length.).
(Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
29 29 Supply of Cast iron Shunt signal surface base Numbers 2.00 2383.65 4767.30
80 mm as per spec No.IRS S 10 and Drg
No.2011/M with latest amendments, as per
RDSO Drg No. SA-23156/Drg.No.RST/11413
as per extent C.Rly practice (Inspection by
30 30 Supply of Signal No.plates. as per Drg No Numbers 20.00 600.20 12004.00
RST-11393 / SK-842 (Inspection by
31 31 Supply of Stop Board/IB Board as per RST- Numbers 20.00 3433.78 68675.60
11791 (STOP BOARD)/ RDSO Drg No.7235/B
as per extent C.Rly practice. (Inspection by
32 32 Supply of Hand Cuff Locks/ Godrej Navtal Numbers 100.00 329.28 32928.00
lock with Three common keys. (Inspection by
33 33 Supply of Shunt Signal Position Light Type Numbers 2.00 16049.79 32099.58
FRP complete as per RDSO Specification
No.RDSO/SPN/ 194/2006/Rev.2.0 or latest
with Off set bracket 3-1/2" to be fitted on 140
mm post drawing No. SA 23840(Adv) Alt-2
for dependent type complete with signal unit
bracket, terminals etc without lenses, lamp,
lamp holder, and to suit LED Signal lamps.
(Inspection by RITES)
34 34 Supply of Phenolic 10mm thick sheet, grade Numbers 10.00 5506.62 55066.20
P3 in standard size of 1.22X1.22 Mtr as per
spec. No IS 2036 of 1995. (Inspection by
35 35 Supply of ARA Terminal blocks with links Numbers 2000.00 76.15 152300.00
made of PBT Specn No.IRS/75/2006(Rev-2)
with latest amendments and RDSO
Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-
(Inspection by RDSO)
36 36 Supply of cartridge fuse block made of PBT Numbers 100.00 170.89 17089.00
as per RDSO Drg No SA-23748 Alt 4, SA-
23749 & Spec No IRS S 75/2006 with latest
amendment. Fuse block shall be suitable for
round head type voltage fuses. (Inspection
37 37 Supply of round head type non detoriating Numbers 100.00 73.55 7355.00
type low voltage cartridge fuse as per Specn
No IRS/S/78/92 with latest amendments
2A/4A/6A capacity (Inspection by RDSO)
38 38 Supply of Tik-tak, piano type switches,5 A (as Numbers 10.00 35.04 350.40
per IS Specification). (Inspection by
39 39 Supply of three pole plug and socket 5 Amp Numbers 10.00 242.12 2421.20
(as per IS Specification). (Inspection by
(Inspection by Consignee)
41 41 Supply of Apparatus Case with godown locks Numbers 10.00 16801.57 168015.70
with detachable handle on both the doors. (a)
Single Case as per Drg. No.SK 783-1 & 2 with
latest alteration. (Inspection by RITES)
42 42 Supply of earth electrode assembly as per Numbers 12.00 1214.88 14578.56
Drg.No. CR/S&T/SK-815 (Inspection by
PUNE DIVISION-S AND T/CENTRAL RLY
RDSO/SPN.197/ 2008 or latest consisting of :
1) Copper bond steel electrode 3 Mtr long
17mm dia with copper bonding thickness of
min. 250 micron & UL listed & marked-01 No.
2) Earth enhancement compound RDSO
Approved in sealed bag of 10 Kgs - 03 No. 3)
Copper strip 150 x 25 x 6mm - 02 No. 4)
Copper strip 300 x 25 x 6mm - 01 No. 5) 35
Sqmm Copper Cable to connect earth
electrode to MEEB - 15 Mtr Approx.
(Inspection by RDSO)
44 44 Supply of 35 Sq.mm Multistrand Single Core Metre 50.00 467.48 23374.00
PVC Insulated Copper for connecting earth
bus bar to earth electrode. (Inspection by
45 45 Supply of Copper Tape 25x6 mm (Bonding Metre 50.00 915.11 45755.50
ring conductor) mounted on insulated
standoff (1 round). (Inspection by Consignee)
46 46 Supply of Track Lead Junction Boxes as per Numbers 20.00 1205.70 24114.00
C.Rly Drg. No.RST 11509 made from fiiber
glass alongwith terminal blocks. (Inspection
specn.No.IRS.S.65/83 (Amd.3) with latest
amendments. (Inspection by Consignee)
48 48 Supply of adjustable Track Feed Resistance Numbers 5.00 1482.01 7410.05
disc type 7.5/15/30 ohms as per RDSO Drg.
No. SA 20161-66/M (Adv) with latest
amendments (with Phenolic moulded base).
(Inspection by Consignee)
49 49 Supply of Track feed battery chargers, 110V Numbers 5.00 2796.06 13980.30
AC input 2, 4 to 6 V DC Output to
Specn.No.IRS.89/2013 Ver.1.0 with latest
amendments. Charger shall be suitable for
charging 80 AH battery. (Inspection by
50 50 Supply of Channel Pins single groove, Numbers 10000.00 2.31 23100.00
galvanised, 7 mm suitable for 4mm dia
bonding wire as per spec No. IRS: S 17-75
Revision 3. (Inspection by Consignee)
51 51 Supply of PVC jacketed wire rope for Track Metre 4000.00 59.94 239760.00
Lead connections. PVC jacketed wire rope
should be of Galvanised steel wire rope 6 mm
dia (6x19 stranded wire with steel core of 6
mm dia) sheathed with PVC 2mm wall
thickness, overall thickness being 10 mm.
PVC sheath should be made of type 6
compound as per IS 5831 of 1984 Reaffirmed
2001 and steel wire rope as per IS:
2266:2019. Reclaimed or recycled material
should not be used. (Inspection by
52 52 Supply of 8 SWG GI wire (4mm dia) suitable Kg 50.00 99.89 4994.50
for track circuit rail bonding. As per IRS
Specification S:13@45>46@ (Inspection by
53 53 'Supply of Hydrometer, Exide make or similar Numbers 10.00 326.33 3263.30
for measuring specific gravity of Battery
Graded acid with mounting stand in location
Boxes.Consignee inspection under
manufacturer certificate. (Inspection by
PUNE DIVISION-S AND T/CENTRAL RLY
54 54 Supply of William stretcher nylon insulation Set 20.00 611.92 12238.40
set suitable for ground connection as per
RDSO drg No T-10367, T-10368, T-10384 as
applicable and to the spec IRS S 23 & 40/84
with latest amendements . (Inspection by
55 55 Supply of Tongue attachment nylon Set 20.00 389.21 7784.20
insulation set consisting of one insulating
plate as per Drg no: RST-106961 & 3 nos of
Ferrules with collars to suite rodding supplied
as per RDSO spec & Drg.no: RST-10692
(Inspection by Consignee)
56 56 Supply Gauge Tie plate nylon insulation as Set 20.00 280.85 5617.00
per RDSO drg No: T- 10372 Alt2, T- 10368, T-
and to the spec IRS S 23 & 40 with
amendement 01 or latest amendements.
(Inspection by Consignee)
57 57 Supply of GI bend pipe, 'B' class, 50mm dia Numbers 20.00 290.82 5816.40
for cable entry in point machines, alongwith
required fixing arrangements as per standard
practice on Central Railway. As per Drg No.
RST.11835. (Inspection by Consignee)
58 58 Supply of GI pipe, inner dia. 100mm dia. B- Metre 180.00 1079.54 194317.20
class as per spec. No.IS 1239 PT. 1/2004 or
l a t e s t with sockets and fittings.
TATA/JINDAL/ZENITH BIRLA make. (Inspection
59 59 Supply of DWC HDPE pipe with one snap fit Metre 120.00 337.11 40453.20
coupler and 'O' ring fire resistant, anti
rodent, in 6 meter length of size 120 mm
outer dia as per RDSO/SPN/204/2011 Ver. 1.1
with Amd.1 or latest. (Inspection by
60 60 Supply of RCC pipes half round of size Metre 500.00 232.30 116150.00
150mm dia outer and 100 mm dia internal 1
mtr long matching to IS No. 458/2003
amendment-1 with Rev.4. (Inspection by
61 61 Supply of Modular terminal block of 2.5 Numbers 1500.00 131.98 197970.00
sq.mm 2 in 2 out type disconnect type
terminal along with as per
RDSO/SPN/189/2004 Rev 3.0. The current
capacity of 16 Amps and more. The terminal
should have marking at centre to view
description from front. Material to be
procured from RDSO approved firms only.
(Inspection by RDSO)
62 62 Supply of DIN Channel for the terminals 1 Numbers 25.00 244.23 6105.75
Mtrs each. (Inspection by Consignee)
63 63 Supply of End plates for modular terminal Numbers 125.00 26.36 3295.00
block. (Inspection by Consignee)
64 64 Supply of End Clamp for modular terminal Numbers 250.00 18.95 4737.50
block. (Inspection by Consignee)
65 65 Supply of Marker Card as per customer spec. Numbers 150.00 94.45 14167.50
(10x10) (Inspection by Consignee)
66 66 Fuse terminal block with LED indication upto Numbers 100.00 209.22 20922.00
2.5 sq.mm screw type one in one out
(suitable for (400 mA, 630mA, 1A. 1.6A, 2A,
4A, 6.3A & 10A) as per RDSO/SPN/189/2004.
(without fuse) (Inspection by Consignee)
67 67 End plate for through terminal block with Numbers 100.00 15.67 1567.00
LED indication. (Inspection by Consignee)
4A, 6.3A & 10A) (Inspection by Consignee)
69 69 Shorting link isulated Grey in colour. Numbers 300.00 16.97 5091.00
(Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
70 70 Operating tool (operating tool, screw driver & Numbers 1.00 9963.56 9963.56
stripper) as per item no.3.1 of Chapter-III.
(Inspection by Consignee)
71 71 Supply of 4.5 Kg CO2 type fire extinguisher Numbers 20.00 5774.51 115490.20
alog with all accessaries, extinguisher testig
certificate has to be supplied along with -
Supply of ISI marked Carbon di Oxide type
(BC) fire extinguisher of 4.5 Kg capacity
confirming to IS 2878:2004 from seamless
cylinder, with IS marked control value, high
pressure mtr., Long discharge hose and horn
complete with initial gas charged with
carrying handle and wall mounting braket
etc., as required by Site Engineer. (Inspection
72 72 Supply of Permanently Lubricated HDPE Kilometre 0.50 84047.56 42023.78
Telecom duct of size 50/42 mm and
accessories as per latest Specification TEC
GR No. GR/TX/CDS-008/03/March 11 with
latest amendment" for OFC cable of size 24
fibre armoured in length of 1000 mtrs/roll.
Duct to be supplied from TEC approved
sources. (Inspection by Consignee)
Item- 2 Part-II : Execution Portion (SOR Items)
S No. Item Description of Item Unit Qty Rate Amount
1 1 Termination of cable cores on ARA Numbers 4000.00 13.14 52560.00
terminal/disconnecting links in the cable
termination rack. This includes all assosiated
works of pulling out the cable from under
ground, peeling off insulation, dressing of
cable core supported on sting rod with
contractors own material. The work shall be
done as per instructions of Rly engineer at
site. (Inspection by Consignee)
2 2 Charging of 2V Lead Acid Batteries with Per Unit 15.00 87.29 1309.35
contractors own battery grade sulphuric acid
and distilled water with minimum two charge
- discharge cycles, installation of charged
batteries in groups & their connection &
wiring. The work shall be done as per extant
practice of C.Rly & instruction of Engineer-in-
charge.Detailed measurements of initial
charging shall be recorded jointly by
contractor & Rly's site-in-charge. (Inspection
by Consignee) [Unit to be read as - Per 100
3 3 Circuit wiring/jumpering as per circuit Per Unit 5000.00 13.71 68550.00
diagrams in the relay racks/IDF rack
tagbloc k s. This includes preparation of
Jumper sheets by wire man duly checked by
firm's site supervisor & wire to wire testing as
per circuit diagram. Any wrong jumper done
by wireman will not be paid & correction shall
be done free of cost. Jumper wires will be
issued by Railways. Good quality solder rosin
core to be supplied by contractor for
soldering of Jumper wires. Soldering of
jumper wires to be done after completion of
testing by Railways. (Inspection by
Consignee) [Unit to be read as -Jumper].
PUNE DIVISION-S AND T/CENTRAL RLY
4 4 Plugging of relays, Provision for temporary Per Route 250.00 388.58 97145.00
relays for N1 working if any, laying of
temperory cables for mock panel and wiring
of Mock panel. Panel through testing of PI/RRI
as per selection table, control table etc. This
also includes alteration if any in panel wiring,
laying & termination of indoor cables from
Panel to IDF/CT rack of relay room .
Contractor shall depute Supervisor &
wiremen technically qualified to carryout
Panel through testing as per approved
design. Technical knowledge of contractor's
staff will be judged by Railways Engineer
incharge before permiting them to do the
testing. (Inspection by Consignee)
5 5 Relay Contact break test of indoor relay Per Unit 100.00 348.69 34869.00
w iring. Contractor shall depute Engineer,
Supervisor & wiremen technically qualified to
carryout contact break testing as per
approved circuit diagrams. Firm Engineer to
sign circuit diagrams for break testing after
carrying out the test in presence of Railway's
site supervisor/Engineer. (Inspection by
Consignee) [Unit to be read as - A3 Size
circuit per Sheet].
6 6 Functional testing of PI/RRI/IBS/Autosignal Per Route 250.00 363.93 90982.50
etc. as per Selection table, control table,
sqare sheet etc. Contractor shall depute one
Engineer, one Supervisor & wiremen
technically qualified to carryout functional
testing as per approved design. Technical
knowledge of contractor's staff will be judged
by Railways Engineer incharge before
permitting them to do the testing. (Inspection
7 7 Lettering & Numbering of detail and Rack 10.00 387.59 3875.90
description writing of particulars of
terminations & equipments on relay rack,
relays, cable termination rack, battery &
power equipments, IPS, operating panel, axle
counter etc constituting entire system with
contractor's own paint and writing material
("Asian/Dulux" make enamel paints to be
used). The work shall be done as per extant
practice on C.Rly & instruction of Rly
engineer at site. (Inspection by Consignee)
8 8 Preparation of cable route plan, cable Lot 1.00 58842.92 58842.92
coreage plan, location particulars, Cable
termination rack particulars, cable
meggering report, earth resistance
particulars, Traction bonding diagram, 1/2
wire count sheet and any other drawing in
Autocad in A3/A4 size.The contractor shall
initially supply 3 sets of circuits complete for
approval of Railways. Railways will return
one set to the contractor duly approved with
alterations/corrections if any. The contractor
shall incorporate Railways
alterations/corrections in the tracings without
any deviation and submit all tracings
complete in all respects to the Railways . This
includes submission of final cable route plan
as per laid cable duly measured at every
30m clearly indicating distance of laid cable
from fixed point of reference & indicating all
track crossings and tail cables. This also
include designing of cable coreage plan
based upon I.P in consultation with engineer-
in-charge. (i) For big yards (> 100 routes)
(Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
9 9 Design and supply of Detailed Signalling Lot 1.00 1288556.77 1288556.77
Circuits including Panel diagram(if required) ,
Route section Plan , Selection Table , Fuse &
Negative Tag. Analysis , Contact analysis ,
Relay Rack Arrangement and wire count
sheets etc. in A3 size.Completion circuit shall
be plotted in AutoCAD. The contractor shall
initially supply 2 sets of circuits duly signed
by the circuit designer having substantial
experience on design side for making such
circuits, complete for approval of Railways.
Railways will return one set of circuit to the
contractor duly approved with alterations
/corrections, if any. The contractor shall
incorporate Railway's alterations/corrections
in the original tracings & CD without any
deviation and submit two copies of the
modified circuits. Original tracings so
modified & final CD complete in all respects
alongwith 6 sets of final approved circuits
(out of which one set shall be supplied in
transparent bags. Only two sheets of circuits
shall be placed in one bag each ) shall be
submitted to the Railways in case there are
no further alteration suggested by Railways.
This also includes modification in yard. (i) for
major yards and stations having more than
200 routes (Inspection by Consignee)
10 10 Excavation and Casting of Shunt signal Numbers 2.00 3047.93 6095.86
foundation as per Drg No SK 802 with
contractor's own materials including cement
and anchor bolts of standard size. The
required scaffolding Ferma etc for Casting of
foundation will have to be brought by the
contractor at his own cost. (Inspection by
11 11 Erection of shunt signal with Surface Base, Numbers 2.00 553.90 1107.80
Post, Signal unit and fixing of No.plates. The
work shall be done as per instructions of Rly
engineer at site. (Inspection by Consignee)
12 12 Fixing of Stop Board, Block section limit Numbers 20.00 636.55 12731.00
Board, goods warning board with contractors
own material. The work shall be done as per
instruction of Rly engineer at site. (Inspection
13 13 Termination of tail cable on Shunt signal Numbers 2.00 409.84 819.68
units and wiring with contractor own
material, fixing of lenses etc. The work shall
be done as per instruction of Rly engineer at
site. (Inspection by Consignee)
14 14 Fabrication and fixing of phenolic Numbers 10.00 2361.58 23615.80
laminated/Fibre glass sheet in location box
by providing all fixtures as per Railway
Drawing including fixing of PVC coated/with
PVC pipe covered string rods at the back side
for cable support with contractor's own
materials. The work shall be done as per drg
and arrangement similar to SK 783-1&2. with
latest alterations & as per instructions of Rly
engineer at site.. (a) Single Case (Inspection
15 15 Fixing of ARA Terminals and fuse blocks on Per 2000.00 14.74 29480.00
phenolic laminated sheets and fixing by Conductor
stainless steel/brass nuts & bolts. This
includes provision of two additional holes on
the board on either side for cable conductor
entry. (Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
16 16 Termination of cable cores on ARA Per 4000.00 11.09 44360.00
terminal/fuse blocks in the apparatus Cases/ Conductor
cable termination rack. This includes all
associated works of pulling out the cable
from underground. The work shall be done as
per location plans and instructions of Rly
engineer at site. (Inspection by Consignee)
17 17 Excavation and Casting of Apparatus Case Numbers 10.00 10369.35 103693.50
foundation with contractors Anchor bolts,
cement, ballast and other materials. The
required scaffolding Ferma etc for Casting of
foundation will have to be brought by the
contractor at his own cost. (i) Single Case as
per Drg No . SK-803 (Inspection by
18 18 Erection of Apparatus Cases. This includes Numbers 10.00 1151.61 11516.10
filling of location foundations and plastering
(i) Single Case (Inspection by Consignee)
19 19 Installation of Eqpt. (Relays, resistance, Numbers 10.00 1687.78 16877.80
chargers batteries etc.as applicable) & wiring
of the same in apparatus Cases as per
location diagrams & circuit diagrams, as per
Instruction of site incharge and practice. (i)
Single Case (Inspection by Consignee)
20 20 Installation of earth electrode assenbly as Numbers 12.00 2908.63 34903.56
per Drg.No.RE/S&T/SIG/Tender/SK726/85
including earth wire connected through GI
wire 8 SWG supported on M.S. flat of size
6mm x 40 mm to earth electrode as per drg.
No. CR/S&T/SK-815 for sigg. Equipment such
as lever frames, apparatus case, signals,
relay racks,block insruments, and etc. as per
RE manual. The earth value should be less
than 10 Ohms including the lead wire. The
value should be measured in presence of Rly.
supervisor. It should be documented and
painted on earth enclosure made of
concrete.( only earth electrode will be
supplied by Railway). All other material
required for provision of earthing will be
brought by the contractor. (Inspection by
21 21 Erection, Fitting and Rail connection of Track Numbers 20.00 1501.79 30035.80
Lead Juntion Box on two supports(M.S.angle)
with contractor's fixing material and PVC
jacketed wire for track lead connection
including angles of size 40 x 40 x 5 mm 1200
mm length. This will include drilling of holes
for track lead/side connections on rail. The
work shall be carried out as per Drg. No. SK-
845 or/& instructions of Rly engineer at site.
(Inspection by Consignee)
22 22 Provision of bonding with contractor's PVC Numbers 50.00 195.19 9759.50
jacketed wire rope for Track Lead connection.
PVC jacketed wire rope should be of
Galvanised steel wire rope 6mm dia (6 x 19
stranded wire with steel core of 6 mm dia )
sheathed with PVC 2mm wall thickness,
overall thickness being 10mm PVC sheath
should be made of type 6 compound as per
IS 5831 of 1984 Reaffirmed 2001 and steel
wire rope as per IS:2266:2019. Reclaimed or
recycled material should not be used. This
will include drilling of 7.1mm dia holes in rails
(4 Nos) and provision of two jumpers for each
bond, clipping of bonds etc. with contractors
own materials and tools as per instruction of
Rly engineer at site. (Inspection by
PUNE DIVISION-S AND T/CENTRAL RLY
23 23 Provision of bonding with GI wire 4mm dia ( 8 Numbers 50.00 184.64 9232.00
SWG) for track jumper & fish plate joints
bonds. This will include drilling of 7.1mm dia
holes in rails (4 Nos) a n d provision of two
jumpers for each bond, clipping of bonds etc.
with contractors own tools as per instruction
of Rly engineer at site. (Inspection by
24 24 Excavation of cable trench as per cable route cum 1050.00 367.07 385423.50
plan,1.0 mt. deep and 300mm wide along
side the track in normal soil/strata,
conforming to distances as per cable route
plan and refilling after cable laying. This work
includes covering of cable laid in trench by
loose soil for a layer of 50mm thickness after
clearing of route,bushes etc. It shall be
ensured that top of the cables laid is at a
depth of 0.8m or more. It if is less, then the
width and depth shall be suitably increased
and accordingly proportionate payment shall
be made. In case depth of trench is not
achievable due to site conditions
proportionate payment will be made as per
procedure. The work shall be done as per the
extant practice on Central Railway and
instructions of Railway Engineer at site. Drg.
No. SK 805 (Inspection by Consignee)
25 25 Excavation of cable trench as per cable route cum 300.00 611.79 183537.00
plan,1.0 mt. deep and 300mm wide along
side the track in hard soil, conforming to
distances as per cable route plan and
refilling after cable laying. This work includes
covering of cable laid in trench by loose soil
for a layer of 50mm thickness after clearing
of route,bushes etc. It shall be ensured that
top of the cables laid is at a depth of 0.8m or
more. If it is less, then the width and depth
shall be suitably increased and accordingly
proportionate payment shall be made. In
case depth of trench is not achievable due to
site conditions proportionate payment will be
maden as per procedure. The work shall be
done as per the extant practice on Central
Railway and instructions of Railway Engineer
at site. Drg. No. SK 805 (Inspection by
26 26 Cutting of all types of Roads/ platforms cum 20.00 3058.96 61179.20
(ecxcept concrete type) for trenching and
excavation to depth of 300mmx300mm wide
approx. and refilling after laying of RCC/GI
/DWC pipe & to restore them to original
condition. The work shall be done as per
extant practice on C.Rly & instructions of Rly
engineer at site. Drg. No. SK 807 (Inspection
27 27 Fixing of GI pipes for crossing the culverts, Metre 180.00 73.38 13208.40
bridges etc. and concreting of ends with
brick masonry at both ends as per the
instruction of Rly engineer at site. (Inspection
flange/road level (for LC) and 0.3Mtrs. to 0.6
Mtrs wide and back filling after placing of
DWC/RCC/GI pipe.(Placing of DWC/RCC/GI
pipe coverd separately. The ballast disturbed
be screened and dressed as required by
Engineer-in-charge or his representatives and
road tarred immediately. Drg. No. SK 806
(Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
29 29 Laying of DWC/RCC pipes alongwith Metre 120.00 59.62 7154.40
collars/RCC Half round pipes in trenches at
places of track and road crossings, platform
cuttings etc. (Inspection by Consignee)
30 30 Laying of signalling/Power/Telecom cable of Kilometre 25.00 5450.97 136274.25
various cores/sizes in trenches. (Inspection
31 31 Wherever depth of 0.5M cable trench is not cum 30.00 5589.55 167686.50
feasible, cable shall be protected as under:-
Preparation of cement mixture 1:3:6 with
contractor's own materials and spreading
cement concrete mixture layer of 100 mm
thick over the already laid cables in the
excavated trench. (Inspection by Consignee)
32 32 Fixing of modular terminal/fuse blocks Numbers 1500.00 21.92 32880.00
alongwith all accessories with provision of
fixing holes on hylam sheets/side angles of
Loc Box and fixing by galvanised nuts &
bolts. This includes fixing of DIN channel
alongwith PVC Comb type 'C' channel (size 2
inch x 2 inch) for cable termination on
modular terminal. The PVC channel with
cover to be supplied by firm as required. The
work shall be done as per the instruction of
Rly engineer at site. (Inspection by
33 33 Termination of cable cores on ARA terminal / Numbers 4000.00 8.17 32680.00
Disconnecting link/fuse blocks, in the
Apparatus cases/cable termination rack. This
includes all assosiated works of pulling out
the cable from under underground. The work
shall be done as per location plans and
instructions of Rly engineer at site.
(Inspection by Consignee)
bridges/culverts/concrete drawin/mountain
ridges etc. with suitable GI bend shall be
provided where there is turning of pipe as
per the instruction of Site engineer. GI
clamps at every 2m as shown in the drawing
to be fixed. Suitable holes to be made in the
pipe before laying as per the instruction of
the site engineer 10mm dia Drg. No. SK 808.
(Inspection by Consignee)
35 35 Making an entrance for new cable in old Numbers 10.00 531.37 5313.70
existing location, Casting concreting and
curing of foundation and restoring it to old
position by perfect masonry/concreting work.
Contractor will ensure that cable entered in
Location Box is properly protected.
(Inspection by Consignee)
36 36 Laying of RCC half round cement pipe of Metre 500.00 41.07 20535.00
appprox. Size (150/300mm dia X 2 mtr.
length) inside the trench after laying of
cable. Pipes shall be placed as per directives
of site engineer. (Inspection by Consignee)
PUNE DIVISION-S AND T/CENTRAL RLY
37 37 Painting of two coats of synthetic enamel Numbers 10.00 456.68 4566.80
paint over one coat of primer on the
following after scraping & cleaning surface
wherever necessary with contractor' own
supply of paints.Wherever required
contractor shall apply coating of epoxy paint
also as per instructions of site-in-
charge.Epoxy paint will be supplied by
Railways. NOTE:- The paint and primer
should be from M/s Asian paints Co. Ltd.,. The
paints will be primer (IS 5660 of 1970) the
Aluminium synthetic black enamel (IS 2932
of 1974) brilliant white and yellow Painting
two coats of enamel paint over one coat of
p r i m e r. (i) Apparatus Case Full Size.
(Inspection by Consignee)
38 38 Painting of two coats of synthetic enamel Numbers 2.00 207.85 415.70
paint over one coat of primer on the
following after scraping & cleaning surface
wherever necessary with contractor' own
supply of paints.Wherever required
contractor shall apply coating of epoxy paint
also as per instructions of site-in-
charge.Epoxy paint will be supplied by
Railways. NOTE:- The paint and primer
should be from M/s Asian paints Co. Ltd.,. The
paints will be primer (IS 5660 of 1970) the
Aluminium synthetic black enamel (IS 2932
of 1974) brilliant white and yellow Painting
two coats of enamel paint over one coat of
primer. (ii) Shunt signal post with signal unit,
surface base as per Central Railway's
Standard Practice. (Inspection by Consignee)
39 39 Painting of two coats of synthetic enamel Numbers 20.00 102.67 2053.40
paint over one coat of primer on the
following after scraping & cleaning surface
wherever necessary with contractor' own
supply of paints.Wherever required
contractor shall apply coating of epoxy paint
also as per instructions of site-in-
charge.Epoxy paint will be supplied by
Railways. NOTE:- The paint and primer
should be from M/s Asian paints Co. Ltd.,. The
paints will be primer (IS 5660 of 1970) the
Aluminium synthetic black enamel (IS 2932
of 1974) brilliant white and yellow Painting
two coats of enamel paint over one coat of
primer. (iii) Track lead Junction Box. (Black
enamel outside only) (Inspection by
40 40 Lettering / Numbering of Signals, Point Numbers 32.00 65.17 2085.44
Machine, Track Lead Junction Boxes, Block
Joints, Apparatus Cases etc. (each item to be
taken as One Unit) This work will be carried
out as per the standard practice being
followed in Central Railway. (Inspection by
41 41 Lettering / Numbering Termination Numbers 10.00 276.39 2763.90
particulars, equipments names etc., legibly
and neatly inside location boxes. (a) Full
Case. (Inspection by Consignee)
42 42 Laying of HDPE duct in trench and its Kilometre 0.50 5464.60 2732.30
protective work as per direction of site
engineer. (Inspection by Consignee)
Item- 3 Part-III : Supply & Execution portion (Non-SOR Items)
S No. Item Description of Item Unit Qty Rate Amount
PUNE DIVISION-S AND T/CENTRAL RLY
1 1 Supply of tool kit as given below - (i) Service Set 1.00 90280.22 90280.22
test panel including meter for test of track
equipment, tools for mounting and
adjustment of track equipment and standard
jig for drilling of holes in rail (as per
manufacturer specification, list to be given
by manufacture). Each set consists of - Tool
kit ETU001 & EDT001: (a) True RMS digital
multimeter with probe set-1 no. (b) Extended
wired socket to interface with diagnostic plug
- 1 no. (c) Selector switch on panel base - 1
no. (d) Adjustable torque wrench with 13 mm
& 19 mm inserts - 1 set. (e) 19 mm double
ended spanner - 1 no. (f) Dummy wheel - 1
no. (g) Screw driver set with mains tester - 1
no. (h) Drilling template - 1 no. (i) Centre
punch - 2 nos. (j) Carrying case for ETU001 -
1 no. (k) Carrying case for EDT001 - 1 no.
(Inspection by Consignee)
2 2 Supply of AC and DC low current clamp Numbers 1.00 30511.28 30511.28
meter with range 1mA to 100 A; make GTC
CM 100 or similar model from make Fluke,
Rishab, Motwane or similar. (Inspection by
3 3 Supply of Analog Insulation Tester (megger) Numbers 1.00 2616.66 2616.66
Hand Driven Generator, 500 Volts, 0-100
Mega Ohms resistance. Confirmed to
IS:2992-1987, Rotation Speed:160 rpm,
Housed in antimagnetic Metal body with
collapsible handle metallic flap over the glass
window scale, wide and anti-parallax mirror
scale. The megger should be supplied along
with carrying bag and test leads. Warranty
and Calibration certificate to be submitted
with megger by supplier when delivered.
Make: Shanti/CIE/ Nippen/ Motwane/ Kusam-
Meco/Yokins/Rishabh/Waco. (Inspection by
4 4 Supply of True RMS Digital Multimeter, Numbers 1.00 10015.89 10015.89
4000Count, Voltage: 1000V AC/DC. Make
Fluke 17B+or DI-LOG 9206 or Megger Model
no.AVO410. (Inspection by Consignee)
5 5 Supply of digital clamp type earth resistance Numbers 1.00 92603.86 92603.86
tester, Range 0.01 To 1000 Ohm, Motwane
make model DECT-2 or similar. (Inspection
6 6 Supply of digital earth tester of Motwane Numbers 1.00 26985.40 26985.40
make model DET-20 or similar. (Inspection
7 7 Supply of Stencil type LED Route Indicator Numbers 1.00 91299.82 91299.82
indicating 1 to 9 nos. (In the event of failure
of any of the LED Segment, ECR will drop).
(Inspection by Consignee)
8 8 Supply of Nylon Insulations for TWS Point Numbers 100.00 427.56 42756.00
Machines consist of plate to RDSO
Drg.No.S3404 - 02 Nos., Stretcher bar bush
RDSO Drg.No.S23199 - 12 Nos., Flat washer
RDSO Drg.No.S8640 - 12 Nos. Throw Rod
bush RDSO Drg.No.S3436 - 01 No., Flat
washer RDSO Drg.No.S8640/2 - 02 Nos. Lock
rod bush RDSO Drg.No.S22179 - 02 Nos.
Washer RDSO Drg.No.S6840/1 - 04 Nos.
Detection rod bush RDSO Drg.No.S23199 - 02
Nos. Flat washer RDSO Drg.No.S6840 - 04
Nos. and MS Flat washers suitable to RDSO
No.S8640 - 16 Nos., Suitable to RDSO
Drg.No.S8640/1 - 04 Nos., Suitable for RDSO
Drg.No.S4680/02 - 04 Nos. (Inspection by
PUNE DIVISION-S AND T/CENTRAL RLY
9 9 Supply and fixing of Cable Route Marker Numbers 100.00 345.32 34532.00
concrete. (Inspection by Consignee)
10 10 Providing Road Breaker/concreate breaker/ Hour 100.00 1707.96 170796.00
boulder or rock breaker with compressor &
Jack Hammer for Railway work such as
cutting & dismentalling of road
concrete/Brick pucca structure(RCC/Steel
section) including contractors fuel, driver and
all other charges. (Inspection by Consignee)
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .