Executive Engineer
No.69, Sachithanandha Moopanar Road, Thanjavur
Providing Electrical Installation to the Manager(QC) chamber and LAB Section in TNCSC SRM Office Building at Thiruvarur in Thiruvarur District. (Second call)
2024_TCSC_484025_1
5/108/EE/TNJ/DB/DO/2024
Open Tender
Electrical Works
Lump-sum
60 days
Thiruvarur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1,650
14 Oct 2024
17 Sept 2024
26 Sept 2024
17 Sept 2024
25 Sept 2024
17 Sept 2024
Amount
ELECTRICAL WORK
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light point / fan point (for electronic regulator)
Supply and run of 2 of 2.5 sqmm (36/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection using 14SWG TC wire with painting of suitable colour.
Supply and Fixing of 3nos 5Amps(3pin and 2 pin)combined flush with wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with earth connection. (For computer plug Socket)
Supply and fixing of 5A 3Pin and 2pin combined switch flush type wall socket only concealed in suitable T.W box, in flush with wall and covered with 3 mm thick hylem sheet.
Supply and fixing of 5A /15A 3 Pin combined switch flush type wall socket only concealed in suitable T.W box, in flush with wall and covered with 3 mm thick hylem sheet.
Supply and fixing of 8 Way single pole and neutral MCB sheet steel enclosure DB -1 No 6A to 32 A DP MCB as incoming and 6 Nos 6A to 32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Like Standard make)
Supply and fixing of 20Amps DP two poleand Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)[Legrand(MDS) /Hager(L&T)make].
Supply and fixing of 20W 4 Feet LED Fitting with LED on wall or ceiling with PVC unsheathed Copper leads from terminals to the fitting.The LED fitting should have inbuilt Driver unit and as per ISInorms . The Materails should be get approved before Execution at site (Philiphs/ crompton)
Supply and fixing of 1200mm sweep (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod on the existing clamp-
Supply and clarnping of 2 x 6 sq.mm PVC LTUG armoured copper cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 2 x 6 sq.mm PVC armored LTUG cable with earth connection
Earthing as per PWD standard with an earth electrode of 2 mt class ‘B’ GI pipe of dia not less than 32 mm, complete with necessary masonry work.
Supply and run of 1 of No.8 SWG copper wire for earth connection
Supply and Installation Of 2.0 TR Split Type AC Unit (5 Star Rated) with 5 KVA capacity Automatic Voltage Stabilizer with time delay relay (Carrier/Voltas make)
Thiru.E.PACHAIYAPPAN (BID ID -1146572)
Kamalam Electrical Engineering Contractors (BID ID -1147551)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_575093.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .