Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.6 L+₹65,720 (2.64%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹29.4 L+₹4.4 L (17.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹30.0 L+₹5.1 L (20.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹31.7 L+₹6.8 L (27.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Nov 2024, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO CONNECTION PATH, AREA DRAINAGE, FENCING INCL PROTECTIVE WORKS IN VARIOUS UNITS AT BG HAMIRPUR AND REPAIR TO SEWAGE LINES, SEPTIC TANKS, MANHOLES AND OTHER MISC WORKS AT MENDHAR, BG HAMIRPUR IN THE AOR OF AGE B/R-I UNDER GE 881 EWS
2024_MES_666270_2
GE/PNH-19/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹80,000
Yes
6 Jan 2025
19 Oct 2024
11 Nov 2024
19 Oct 2024
8 Nov 2024
26 Oct 2024
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L for laying, spreading and leveling of sand as in cushion for not exc 25 cm thickness to precast concrete interlocking paver block complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
M&L for cement concrete (1:2:4) type-B-1 (using 20mm graded stone crushed aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs, in edging of path (interlocking paver) and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:4, complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in floor/hardstanding finishing cement concrete surface etc complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (20mm graded crushed stone aggregate) as in surface channels & drains, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed by Engineer-in-Charge.
S&F TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B1 (20mm graded crushed stone aggregate) as in landings, cover slab for man holes etc set in cement mortar(1:6), complete all as specified and directed.
Form work to sides of concrete foundations, footings, basis of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to better with rough finished surfaces of concrete complete all as specified & directed
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per Srl item No. 17 above, but except stone complete all as specified and directed.
Plain cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified.
M&L for providing precast cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone agg) as in PCC bonders set in CM 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
M& L for raised pointing in cement mortar (1:4) brought upto courses built in CM complete all as specified and directed.
M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc, and raising (or lowering) to the required level compete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall or as in weep holes material packing at the back shall be provided at suitable horizontal intervals with slope as soil pipe(vent pipe), complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified and directed.
Taking down cement plastering on lathing (other than wire netting) without removing lathing complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
Preparation of old plastered/ un-plastered wall surfaces or wood based surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of cement base paint on walls including cornices, pilasters etc, complete all as specified.
S & F in repair galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measured complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, and removing surplus soil to a distance not exceeding 50m and making good surface in any type of soil, complete all as specified.
Mild steel work as in hand rails, half round or other stock section or core for wooden hand -rail, straight portion drilled and countrsunk for ballusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screqing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed in repairs, and similar work conforming to Fe-250 Gde E-165 all as specified.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt not exc 5 cm and 11 to 15 mm dia complete all as specified and directed.
Dismantling fencing wire mesh, any type ccomplete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
M&L for mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings, steel doors etc. with ends of bars shouldered and/ or riveted or forged into spikes framed guard bars, and similar works complete all as specfied & directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Precast cement concrete (1:2:4) type-B-0 (using 12.5mm graded stone crushed aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame and set in CM (1:4), complete all as specified and directed.
Opening of cover(of any description and size) of septic tanks and soakage wells/pits, desludging/dewatering of septic tanks and soakage wells/pits of any size and depth by Manually operated machine (where approach of veh is not feasible)/mechanical pumping (truck mounted) making it fully functional to the entire satisfaction of Engr-in -Charge and removing sludge outside the periphery of defence land at bis own arrangement where sanitary hazards do not take place as per directions/instructions of civil authority and burried in excavated pits and covering the same including refixing covers after cleaning complete all as specified and directed. Note:- Unit rate quoted by tenderer shall include taking out sludge from line and manholes(liquid/semi liquid/solid) excavtion of borrow pits for dumping sludge, removing including loading/unloading and transportation etc
Cleaning of under ground sewage lines of 100mm/150 mm bore including manholes, CI stacks.gully traps etc. by means of cleaning by roding from manholes to manholes till the cleared/cleaned water running under sewage line and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes including taking off and re-fxing cover the manhole pitt, complete all as specified and directed. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Cleaning of blockage of Water Closet (Indian or European), trap & pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burring in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Demolition or breaking up drain pipe of any size (salt glazed stone ware, AC, PVC or reinforcement concrete) set in cement mortar/concrete complete all as specified and directed.
S&F 150 mm bore salt glazed stone ware drain pipes, grade ‘A’ laid in trenches and jointed in CM 1:3, complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors as soil pipe(vent pipe) complete all as specified and directed.
S&F 150 mm bore reinforced concrete pipes, class NP2, laid in trenches and jointed with collars, complete all as specified and directed.
Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipes for 150mm SGSW pipe after they are laid in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) & tested, complete all as specified and directed.
S&F TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically described complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling, mass concrete and sub base, complete all as specified and directed.
Cleaning of blockage of Indian / european type WC up to first manhole and making the drain pipe of any dia fully functional by flushing with water to entire satisfaction of Engr-in-Charge including disposal of sludge outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/ instructions of civil authority and burried in excavated pits complete all as specified and directed. Note:- Unit rate quoted by tenderer shall include clearing blockage, taking out sludge(liquid/semi liquid/solid ) , excavation of borrow pits for dumping sludge ,removing including loading/unloading and transportation etc.
S&F in repair PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75mm bore diminishing pieces or tapers, complete all as specified.
S&F in repair PVC (SWR) bends any radius 110mm bore diminishing pieces or tapers, complete all as specified.
S&F in repair PVC(SWR) branch piece, double (double Y) equal or unequal 75mm bore, complete all as specified and directed.
S&F in repair PVC(SWR) branch piece, double (double Y) equal or un equal 110mm bore, complete all as specified and directed.
S&F PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern) white, (excluding flushing cistern) complete connection to drain (outgoing pipe) and to flushing pipe and anti syphonage pipe etc with & including fixing bolts, complete all as specified and directed.
S&F in repair Vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, white, with integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe of 32mm dia and syphonage pipe etc, and complete, all as specified and as directed.
S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints, complete all as specified.
S&F in repair 40 mm dia Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm, fixed to wall/ceiling or in floors incl necessary fittings complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for Non skid coloured ceramic tiles of 7-8mm thick (square or rectangular) area of each tile exc 0.06sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed
M&L for Non skid coloured ceramic tiles of 7-8mm thick (square or rectangular) area of each tile exc 0.06sqm but not exceeding 0.11 sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles laid over and including 10mm thick screed bed in CM (1:4), complete all as specified and directed
M&L for water proofing treatment to sunken floor, with slope correction by using M-20 concrete minimum 25 mm thickness at one end and with a slope of 1:20 by using 12.5 mm graded stone aggregate with integral water proofing chemical mixedin proportion 200 ml/50 kg of cement or equivalent as per manufacturer's instruction complete all as specified and directed.
M&L for 25 mm thick PCC padding in 1:1.5:3, type A0 with water proofing compound as per manufacturer's instructio complete, all as specified and as directed.
M&L for 15 mm thick plaster in CM 1:3 with and incl water proofing compound as per manufacturer's instructions with and incl testing of water leakage by ponding test, complete all as specified and directed.
M&L for on site LLDPE septic tank in replacement for 20 users designed to carry sewage and sullage water, incl excavation in any type of soil, with 100 mm thick PCC in 1:4:8 in foundation, vent shaft, all required connections etc complete, all as specified and as directed.
M&L for on site LLDPE septic tank in replacement for 30 users designed to carry sewage and sullage water, incl excavation in any type of soil, with 100 mm thick PCC in 1:4:8 in foundation, vent shaft, all required connections etc complete, all as specified and as directed.
M/S BHATT TRADERS (BID ID -3153092)
M/S MANHAS ENTERPRISES (BID ID -3158968)
M/S BADRI NATH GUPTA (BID ID -3159706)
M/S KHAN ENTERPRISES (BID ID -3154764)
Modh Hafiz Khan (BID ID -3159214)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .