Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹21.3 L+₹72,995 (3.54%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not lowest bidder | |
| 3 | L3₹25.9 L+₹5.3 L (25.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest bidder | |
| 4 | L4₹32.7 L+₹12.1 L (58.6%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Being not lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
21 Dec 2019, 6:00 pmClosed
GE
GE (AF) MC CHANDIGARH
REPAIR AND MAINT OF EXTERNAL ELECTRIFICATION SERVICES LT POLE PAINTING AND OTHER CONNECTED WORKS AT BRD AF STN CHANDIGARH UNDER GE AF MC CHANDIGARH
2019_MES_301462_1
GE(AF) MC CHD-41/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) CHANDIGARH
₹70,000
Yes
GE (AF) MC CHANDIGARH
29 Jan 2020
27 Nov 2019
23 Dec 2019
27 Nov 2019
21 Dec 2019
7 Dec 2019
28 Nov 2019 - 5 Dec 2019
5 Dec 2019
Amount
M & L for GI pipe bracket, made out of 40 mm dia medium grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos MS clamp of MS flat iron 40x 6 mm with bolts, nuts and washer including painting with two coats of synthetic enamel paint over a coat of primer complete all fixed on poles/ walls, IN REPAIR including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in Charge. Make of pipe - Jindal/BST/Surya/Swastik/prakash.
Supply and fixing of PVC insulated and PVC sheathed, multi stranded copper conductor cable,3 X 2.5 sqmm 3 core cable for earth wire Single core, 1100 volt to keep in side of pole for connection from junction box to street light fitting etc complete all as specified and directed by Engineer-in-Charge.( Note :- Three run of cable consider as one run of cable for measurement and payment purpose only ) Make - Havells/Plaza/Polycab/Finolex
Supply and fixing in thermoplastic cable junction boxes IP 66/67 weather proof for outdoor installation with metric knockout for cable entry of size 255x355x122mm fixing on pole/wall with MS clamps/MS flat iron of size 25 x 4mm (as per site requirement) nut bolts, washers painting with two coats of of synthetic enamel paint 1st qualitystandard shade over a coat of primer all as specified and directed by Engineer-in-charge. Make- Hansel / Neptune / Sintex
Supply and fixing 'IN REPAIR'energy saving LED street light fitting of 45 Watts capacity high pressure die cast alumunium housing with seal toughned glass cover light source should be multi LED SMD array with individual secondary lences, colour temperature 6000 K + 500 K. system efficacy should be minimum 100 Lumens/watt and minimum system lumen package of 9000 lumens voltage range 120-280 Volts IP 66 THD less than 10 % company logo make should be embosed on the housing of the luminaire, surge protection minimum 5 KV with flash indication, Driver should be potted/ CE certified/ R certified and driver efficiency 85 % including Taking out existing unservecable LED/MH/Sodium Vapour/CFL street light fitting any size and any type , any capacity complete all as specified and directed by Engineer-in-Charge. Make:- Crompton/Havells/C&S
Description all as per item No. 4 herein before but 70 Watts Capacity.
Description all as per item No. 4.0 herein before but 110 Watts Capacity.
Supply and fixing IN Repair energy saving LED Flood light of 100 Watts Capacity powder coated PDC alumuninum housing with seal toughned glass cover, light source should be multi LED SMD array with individual secondary lenses, color temerature 6000 K , 500K(+-) system efficacy should be minimum 100 lumen/watt and minimum system lumen package of 12000 lumen as LM 79 operating voltage range 120 -180 Volts IP -66 THD Less than 10% b surge protection minimum 5KV with flash indication, driver should be potted / CE cretified/R cetificate and Driver efficiency 85% including making connection and Taking out existing unservecable LED/MH/Sodium Vapour/CFL street light fitting any size and any type , any capacity complete complete all as specified and as directed by Engr-In-Charge. Make :Havells / Crompton/C&S.
Description all as per item No. 7.0 herein before but 70 Watts Capacity.
M&L IN Repair PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 6.00 sqmm drawn through conduit pipe/bracket or along the wall/pole as in trenches including fixing or conduit/bracket and making connection to the fitting with over head line i.e connector to junction box fixed at bottom of pole complete all as specified and as directed by Engr-In-Charge Make : Rallison/Finolex/Plaza/Gloster
Description all as per item No. 9.0 herein before but cable of size 10.00 sqmm.
M&L for preparation of rusted surface of steel pole with brackets of any size/shape/type at any height and painting with aluminium paint and alternate colour of sky blue 3 strip and white paint 2 strip of 30 cm height at bottom of the pole ( appx 1.5 mtr )and numbering the pole (with 5 cm height ) black paint with back ground yellow paint 10 cm dia round complete all as specified and as directed by Engr-in-Charge. Make of Paint -Asian/ICI/Berger/Shalimar
Material and labour for preparation by removing the peeled old paint with scrapper, cleaning the surface of rusted surface of HT/LT panel/MS Air vessel/MS Air pipe complete portion of any size and Spray painting to outdoor with two coats of synthetic enamel paint of 1st quality as per standard shade and colour approved complete all as specified and directed by Engineer-in-Charge Make of Paint -Asian/ICI/Berger/Shalimar
M&L for LT PVC self adhesive electrical insulation tape of size W-30mmx L-15 Mtr x T- 0.125 mm ISI marked for cable insulation complete all as specified and directed. Make: Anchor/PCG
Supply fixing and commisioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. 'IN REPAIR' complete all as specified and directed by Engineer-in-Charge of size 16 Sqmm 4 core. Make: Havells/Polycab/Paragon. NOTE: Excavation, earth work, sand cushioning, cable cover & pipe for cable protection shall be measured and paid for separately.
Description all as per item No. 14 herein before but size 25 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 35 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 50 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 95 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 120 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 185 sqmm 3.5 core.
Description all as per item No. 14 herein before but size 240 sqmm 3.5 core.
Boring of holes by the machine under road, pavement, hard standing by drilling for and including running metre laying of 50mm GI pipe medium grade for cable or laying electric cable of any size complete all as directed. Make of pipe - Jindal/BST/Surya/Swastik/prakash.
Boring of holes by the machine under road, pavement, hard standing by drilling for and including running metre laying of 80mm GI pipe medium grade for cable or laying electric cable of any size complete all as directed. Make of pipe - Jindal/BST/Surya/Swastik/prakash.
Material & Labour IN REPAIR for LT Feeder Pillar of size not less than 60 cm x 45 cm x 45 cm made out 3 mm thick out door type (CPRI approved) factory made with openable Front door including locking arrangement with 4 nos of aluminium bus bar 400 amps rating and fixed on angle iron frame with suitable insulators and PCC plinth including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge
Supplying, jointing and connecting straight through LT joints (heat shrinkable) for underground cable including jointing kits & labour complete joints suitable for aluminium conductor cable suitable for 120 to 185 Sqmm cable complete all as specified and directed by Engineer-in-Charge Make : Birla 3M/Raychem/M-Seal/Capseal
Discription all as per Item No 25.0, but suitable for cable 70 sqmm to 95 Sqmm complete all as specified and directed by Engineer-in-Charge
Discription all as per serial Item No 25.0, but suitable for 16 to 50 Sqmm cable complete all as specified and directed by Engineer-in-Charge
Supply and fix cable joint kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 to 240 sqmm 'IN REPAIR'complete all as specified and directed by Engineer-in-Charge Make : Birla 3M/Raychem/M-Seal/Capseal
Descrption all as per serial item No 28.0, but out door type complete all as specified and directed by Engineer-in-Charge
Descrption all as per serial item No 28.0, but straight through complete all as specified and directed by Engineer-in-Charge
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead 32x6mm GI strip by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40 mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh complete including excavation and earth work, PCC chamber in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate including 50 mm thick precast cement RCC cover in (1:2:4) type B1 reinforced with 8 mm dia TMT bar @ 75 c/c both ways with 2 nos lifting handles of 12 mm dia MS plain bar duly painted with two coats of synthetic enamel paint, GI pipe 20 mm dia light gde with funnel & wire mesh for watering and 40 mm light gde GI pipe for earth lead protection etc complete all as specified and shown in electrical plate No 3 of SSR Part-I Note :- GI strip and protection pipe upto 7.5 mtr length is included in the rate quoted above
All as per item No. 31 herein before but size of earth lead GI wire 4mm dia.
Taking down unserviceable Automatic transfer switch & supply and fixing Automatic transfer switch 4 pole of capacity 315 Amps, AC, 50 HZ, 415 Volts with sheet metal enclousure out door type all as directed by Engineer-in-charge. Make- Havells/C&S/Legrand
Description all as per serial item no 33. but 160 Amp all as specified and directed by Engineer-in-Charge
Supply & fix 'IN REPAIR' MCCB 3 pole 415 volts 630 Amps with fixed thermal magnetic release 50 KA breaking capacity with sheet metal enclosure or replace with existing LT panel including taking down old unserviceable MCCB all as specified and directed by Engr in Charge. Make : Hager/L&T/C&S
Description all as per item no 35. herein before but 500 Amps breaking capacity 36 KA.
Description all as per item no 35. herein before but 350 Amps breaking capacity 36 KA.
Description all as per item no 35. herein before but 200 Amps breaking capacity 36 KA.
Description all as per item no 35. herein before but 100 Amps breaking capacity 16 KA.
Supply & fix in replacement ACB 4 pole 415 volts breaking capacity 50 KA manual drawout type with microprocessor release of capacity 630 Amps including taking down old unserviceable ACB all as specified and directed by Engr in Charge. Make : Havells/L&T/C&S
Description all as per item No.40. herein before but capacity 800 Amps.
Description all as per item No. 40. herein before but capacity 1000 Amps.
S&F Amp meter square flush mounted digital type of size 96x96mm of range 0 to 100 Amp including taking out old unserviceable amp meter complete all as specified and directed by the Engineer-in-Charge. Make : HPL/L&T/AE/Siemens/GE/Secure Meters
S&F Volt meter square flush mounted digital type of range 0 to 500 Volt including taking out old unserviceable Volt meter of any type complete all as specified and directed by the Engineer-in-Charge. Make : HPL/L&T/AE/Siemens/GE/Secure Meters
S&F indicating lamp industrial LED type R, Y, B including taking out old unserviceable indicating lamp complete all as specified and directed by the Engr -in -charge. Make :- AE/Kay/Siemen.
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m depth and getting out in any type of strata for locating fault, laying of cable and pipe or taking out old u/s cable complete including taking out & stacking old bricks/pipes, etc and making good to the disturb surface complete all as specified and directed.
Returning and filling in, including spreading and well remming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed.
M&L for dry sand cushioning to under ground cable in trenches including spreading, levelling and hand punning complete all as specified and directed.
Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the axis of cable, complete all as specified and directed.
Laying only old bricks taking out as excavation of existing cable for cable protection complete all as specified and directed by Engr in Charge. (Note- Bricks retrived from seial item No 47 of BoQ)
Supply and fix cable tray 3 metre long,made out of wiremesh tray 300 x 54 mm electro galvanised type with mess of 6 Sqmm diameter wire size alongwith accessories like EDRN coupler, supports etc all as specified and directed. Make : LEGRAND/SCHINDER or equivalent make complete all as specified and directed by Engr in Charge.
Supply and fix time light distribution board (Security light timer) time light 63 Amps TPN Astronomical Time Switch and Contactor size of 65 Amp TP for security light control with enclosure complete all as specified and directed. MAKE - Havells Cat Part No - IHXTS0912A or equivalent make of Legrand/ABB
Supply and fix cross arms ,bracings,supports,clamps and black plates fabricated from structural steel sections including nuts,bolts,washers, welding,bending cold or hot ,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of Synthetic enamel paint all as specified and directed by Engr in Charge.
M&L for 40 mm thick Cement concrete type B-1, 1:2:4, 20 mm graded in coping etc including using necessary form work complete all as specified and directed by Engineer-in-charge.
Raman Electric Trading Co
SATYAM ENGINEERS
HARISH SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .