Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
16 Nov 2026, 6:00 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (AF) Amla
GE (AF) Amla, Amla Depot Distt Betul (MP) 460553
TESTING AND REPAIR /MAINT OF EARTHING AND LIGHTENING PROTECTION SYSTEM TO SHED IN X AREA AT AFS AMLA
2026_MES_794805_1
8746/E8 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (AF) Amla
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
16 Nov 2026
19 Oct 2026
18 Nov 2026
19 Oct 2026
16 Nov 2026
2 Nov 2026
19 Oct 2026 - 26 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Checking, routine maintenance and attending daily complaints of lightening protection system (LPS) of Storage Sheds/ Technical Buildings in Depot & Domestic area and making LPS in 100% serviceable condition including rectification complaints complete all as specified and directed. The detailed scope of maintenance includes:-
(a) Routine Checking/ Inspection (Monthly Task): Inspection of lightening arrestor of Storage Sheds/ Technical Buildings for tightening of loose nuts on epoxy insulators, rusting of lightening conductor strip/AT Rod, bend/down of AT Rod/strips, open strip/conductor, condition of earth pits. | 450 | Each Job | - | - |
| 1.01 | (b) Attending Complaints (Breakdown Maintenance): Attending emergency site complaints of loose connections, or earth-neutral voltage faults promptly within a stipulated turnaround time (within 72 hours) which involves changing damaged LAs, fixing disconnected terminal connectors, or updating damaged down-conductors.
(c) System Upkeep: replacing defective or eroded AT rod, rusted/deteriorated roof/down conductor, securing down conductors and cleaning support insulators. | - | - | - | - |
| 2 | Labour charges to carry out earthing resistance test of earth pits of Lightening Arrestor (LA), Equipment (EQ), Power Supply (PS) of Storage Sheds/ Technical Buildings in Depot & Domestic area with well calibrated suitable earth resistance tester after opening the test points and recording the result in presence of MES representative complete all as per IS:3043 of 1966.
Note:- (i) The result shall be recorded in the result sheet as directed.
(ii) Recording the test result of each earthing shall be done on monthly basis and the test result shall be submitted to the AGE E/M Office quarterly basis.
(iii) It shall be ensured by the Contractor of earth resistance meter shall be well calibrated. | 13,750 | Per Earthing | - | - |
| 3Taking down old defective conductor strips of any type/description (i.e. GI, Aluminium & copper strip) from wall/ roof and making good to the disturbed surfaces to match the existing surface complete all as specified & directed. | |||||
| 4 | Supply & fix aluminium conductor, steel reinforced fixed on poles as suspended conductor after taking down old one complete all as specified and directed. | 0.5 | Qtl | - | - |
| 5 | Supply and fix funnel made out of aluminium sheet in conical shape, dia of the funnel should be similar to existing funnel complete all as specified and as diirected. | 75 | Each | - | - |
| 6 | Supply and fix light grade GI pipe 40 mm dia for protection of earthing lead complete all as specified and directed. | 45 | RM | - | - |
| 7 | Supply and fix in replacement test point terminal block made of gun metal or phosphorus bronze of size 75 x 75 x 25 mm drilled and screwed by providing 3 Nos 8 mm dia 25 mm long hexazonal head screw on epoxy insulators and connected to Copper/ Aluminium / GI strips housed in junction box after taking down old one complete all as specified and directed. | 100 | Each | - | - |
| 8 | Supply and fix in repair copper strip of size 100 x 50 x 5 mm drilled and screwed including 3 Nos 8 mm dia screw and washers connected to Copper/ Aluminium / GI strips after taking down old one complete all as specified and directed. | 45 | Each | - | - |
| 9 | Supply and fix in repair air termination single pointed aluminium rod not less than 12mm dia and 300mm long end threaded and taking down old one complete all as specified and directed. | 250 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
FinalTD.pdf
Tender Documents • 0.69 MB
BOQ_891410.xls
BOQ • 1.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .