Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 CrAccepted-AOC 2367 E BAWANA ROAD NARELA DELHI 40 | ₹3.9 Cr | 1 | Accepted-AOC Work order has been issued vide work order No. 21 dated 08.03.2024 |
| 2 | 2₹4.0 Cr+₹10.1 L (2.62%)Rejected-Finance N A | FARIDABAD | HARYANA | 121004 | ₹4.0 Cr+₹10.1 L (2.62%) | 2 | Rejected-Finance Being L2 |
| 3 | 3₹4.1 Cr+₹18.4 L (4.75%)Rejected-Finance N A | NA | NA | 121004 | ₹4.1 Cr+₹18.4 L (4.75%) | 3 | Rejected-Finance Being L3 |
| 4 | 4₹4.2 Cr+₹28.7 L (7.41%)Rejected-Finance | ₹4.2 Cr+₹28.7 L (7.41%) | 4 | Rejected-Finance Being L4 |
| 5 | 5₹4.2 Cr+₹38.1 L (9.85%)Rejected-Finance | ₹4.2 Cr+₹38.1 L (9.85%) | 5 | Rejected-Finance Being L5 |
Tender Value
₹4.7 Cr
EMD Value
₹9.4 L
Closing Date
8 Feb 2024, 9:00 amClosed
Manoj Gupta
Office of the Ex. Engineer (Pr.) Zonal Building, Narela, Delhi-110040
Development of cremation ground at Sec-26, Rohini in ward No. 28 Shahbad Dairy in Narela Zone
2024_MCD_183936_1
E.E.(Proj.)-NZ/TC/2023-24/22/1
Open Tender
Civil Works
Percentage
330 days
Shahbad Dairy
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
₹9.4 L
31 Jul 2024
1 Feb 2024
8 Feb 2024
1 Feb 2024
8 Feb 2024
1 Feb 2024
Amount
Part-B Market Rate Item Rate
1.)Providing Design, Detalled Engineering, suppy, Fabrication, Erection, Installation and placing in position of Architectural Mumbrane primary MS steel Structure work. The structure Fabrication should confirm to the manufacturing standard of Tensile structure speciallzed in fabricationand erection of structures steel.Using Min 250 MPa or more Yleld strength Mild steel built up tubular trusses ( plates, CHS/RHS/ SHS ERW M.S. tube as per Indian Standards and as per approved specifications Make ISI Marked with MTC certificate.) including cutting, hoisting fixing in position.Such as Structures are welded and bolted including special shaped washers etc complete. Hot finished welded type tubes in complete and direction of Engineer-In-Charge. MS ERW CHC pipes as per specification under " IS 1239 (part-1,2004),YST 250" or more; SHS/RHS Pipes as per specification under "IS 4923 (2009),YST 250 MPa or more" and MS plate as per specification under "IS 2062, YST 250 MPa or more". Steel Quy. as per Final Design & Drawing Approve. 2.)Providing and Applying the complete structure to be Two coat of Epoxy primer over one coat of PU Paint (Ist coat (Primer cum MIO) first coat with epoxy primer cum MIO in two components i.e base and hardene. The DFT shall be 125 microns, IInd coat (Primer cum MIO) Second coat with epoxy primer cum MIO in two Components i.e base and hardener. The DFT shall be 1250microns and Finishing coat (to be applied in two coats), Two componeents polyurethane Finish plant with volume solids of minimum 63% 0, Hardtop XP or approved equlvalent, having VOC<320gm /liter, The DFT in two coats shall be 100 microns). The work is to be executed as per technical specification and direction of Engineer-In-Charge.3.)Providing, Fabricating, assembling and erection of Flexible Composite Roof sheeting in desired profile as per conceptual drawing. The sheet should be wieldable having minimum weight of 900 GSW with a minimum Tensile Strength (warp/weft)4300/4200 N/50mm, Tear strength (warp/ weft) 500/500 N having 15 years warranty.The Roofing sheet should have standard specification. The Roofing should confirm to the manufacturing standard of being Pre-stressed in both direction with agencies Tensile Structure specialized in fabrication and erection of roofing sheet Rate includes cost of fabric, shop drawings, patterning, forming, cutting, fabrication,hot weld stitch of fabric, assembling and installation with GI cables, hardware, Aluminnum flat, EPDM gasket and required accessories wherevers required complete including, tools and plants, ect. Required for all operations in all respect complete as per drawing, design, specifications and as directed by Engineer-in- charge. 4.) AS Required Providing & Supplying of GI Cable with MS End Terminals & MS Nut& washer, Diameter as per Design, Type of cable is 6x19 strands of required length of Grade 1570 steel core as per specification under IS 2266 (2002), with MS end terminals at both ends of required length as per approved drawings as Under Membrane cables complete in all respect as per direction of Engineer-in- charge. Tensile Structure with Fabric 900 to 950 GSM Fabric along with 15 years Warranty.
Bidder Name
Amount
Radhey Shyam Garg(GSTN-07ADIPG0933D2Z0)
JINDAL ENTERPRISES(GSTN-NA)
rakesh kumar goel(GSTN-NA)
M/s Amar Const. Co. -I(GSTN-NA)
M/s Pushpa Builders(GSTN-NA)
M/S DINESH KUMAR BUILDWELL(GSTN-NA)
Manoharlal(GSTN-NA)
SANJEEV ASSOCIATES(GSTN-NA)
rakesh kumar goel
Manoharlal
SANJEEV ASSOCIATES
Radhey Shyam Garg
M/s Pushpa Builders
M/s Amar Const. Co. -I
M/S DINESH KUMAR BUILDWELL
SANJEEV ASSOCIATES
rakesh kumar goel
M/s Pushpa Builders
Manoharlal
Radhey Shyam Garg
JINDAL ENTERPRISES
M/S DINESH KUMAR BUILDWELL
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .