Directorate of Municipal Administration
electrical hdmc
Installation of poles in magadi park garden and electrification of hall in sliver park garden of ward 41 of hubballi division.
DMA/2026-27/EL/WORK_INDENT57518
DMA/2026-27/EL/WORK_INDENT57518
Reserved
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Hubballi-Dharawada
8 documents required · 8 mandatory
₹500
₹10,500
12 May 2026
12 May 2026
19 May 2026
Installation of poles in magadi park garden and electrification of hall in sliver park garden of ward 41 of hubballi division.
Octagonal Poles 5 Mtrs Fabricating, supplying and erection of . ms long hot dip GalvanizedOctagonal hot dip Pole with BSEN 10025 grade S 355 JO steel platefor shaft, IS 2062 for base plate with door o...
M.S.Bracket Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1...
Mulit strand 2 Core Copper Wire Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS81301984 and (Virgin) PVCinsulati...
LT UG Cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3...
Laying of cable in Existing Trench/GI pipe/Stoneware/RCC Hume pipe using wooden/Aluminium Rollers as directed by department staff. 2.5 to 25Sqmm. ESCOMs SR 2023-24 Page No 388 Item No 21.05
Earth work excavation For UG Cable In all kinds of soils Depth upto 1.50 m Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specificati...
Pothead Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up 315 35.01 Up to 4C x 50 Sqmm ESCOMs SR 2023-24 Page No 351 Item No 35.01
GI Pipe B - Class as per IS-1239 GI Pipe - 20 mm Dia BESCOM SR 2021-22 Page No 16 Item No 49.01
PLB Pipe 40/33 mm ESCOMs SR 2023-24 Page No 366 Item No 66.05
MCB Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ...
MCB Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ...
Earth excavation Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as p...
Base Concerete Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as ...
Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/we...
Providing and laying in position Reniforced cement concrete for all foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixe...
Contactor Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-1394...
Timer Supplying and fixing Microprocessor based Electronic timer(without contactor, Din Mounting using necessary bolts, nutsand washers etc.,.) 3-120sec setting. PWD Ele SR 2-23-24 Page:21 Item no 5.4...
Fuse Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A PWD Ele SR 2-23-24 Page No.14 Item code 5.7.3
Wood Board Supply and fixing polished wood board made of not less than
15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs scre...
Lugs Aluminium End Terminal (Lug) 25 Sqmm ESCOMs SR 2023-24 Page No.363 Item code 60.03
MCB BOX Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm...
RCC Poles RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 ESCOMs SR 2023-24 [Pg.No: 339 I.No:1.01
26) 2.16)Spiral Earth Electrode Vol 6 - BESCOM - Part III - 11 kV Material
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth ESCOMs SR 2023-24 [Pg.No: 380 I.No:2.02
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. Ordinary Soil ESCOMs SR 2023-24 [Pg.No: 379 I.No:1.1.1
LT 2 Pin Cross Arm - GI
ESCOMs SR 2023-24 [Pg.No:340 I.No:2.08]
LT 4 Pin Cross Arm - GI
ESCOMs SR 2023-24 [Pg.No:340 I.No:2.06]
Fixing of 2 Pin & 4 Pin cross arm with Insulator and Braces fixing ESCOMs SR 2023-24 [Pg.No: 381 I.No:5.01
1.1 KV Pin Insulator
1.1 kV Ceramic Pin Insulator (Shell only) ESCOMs SR 2023-24 [Pg.No: 341 I.No:6.03
1.1 kV GI Pin for 1.1 kV Ceramic Shell Insulator ESCOMs SR 2023-24 [Pg.No:341 I.No:6.04]
No. 8 Strain Insulator
ESCOMs SR 2023-24 [Pg.No:2 I.No:6.07)
Rabbit Conductor
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM ESCOMs SR 2023-24 [Pg.No:341 I.No:7.02)
Stringing of Conductor
Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. ESCOMs SR 2023-24 [Pg.No:...
Guy Wire & GI Wire as per IS-2141
7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM ESCOMs SR 2023-24 [Pg.No:341 I.No:8.01]
MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) ESCOMs SR 2023-24 [Pg.No:341 I.No:5.09]
Turn Buckle (GI)
(Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) ESCOMs SR 2023-24 [Pg.No:341 I.No:5.11]
Anchor Rod using 12 mm rounds/Guy Rod - MS
(Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) ESCOMs SR 2023-24 [Pg.No:341 I.No:5.12]
Digging of Pit for GUY SET
ordinary soil ESCOMs SR 2023-24 Page No 380 . Item No 1.7.1
Bend Clamp Supplying and Fixing.mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL...
Short Point Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated c...
Medium point above 3m upto 6m from tapping point to out let via switch box
PWD Ele SR 2-23-24 Page No. 5 IItem code 2.1.2
Long point above 6m upto 10m from tapping point to out let via
switch box PWD Ele SR 2-23-24 Page No. 5 IItem code 2.1.3
Moudle Switch Plate Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc., comple...
Metal Box Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/...
Swithch 6A Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch
PWD Ele SR 2-23-24 Page No. 9 IItem code 3.6.1
Socket 6A Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket
PWD Ele SR 2-23-24 Page No. 9 IItem code 3.6.3
Cealing Fan Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with do...
Fan Regulator Electronic stepped regulator.
PWD Ele SR 2-23-24 Page No. 10 IItem code 3.14.16
Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of...
LED Fitting In- Door Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@...
LED Light Fixing Charges Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNo...
Lamp Holder Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder
PWD Ele SR 2-23-24 Page No. 10 IItem code 3.14.6
Copper Multi Strand Wire Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of...
Casing Caping SupplyingandfixingofPVCcasingandcappingonthewallorceilingusingnecessarymaterialslikebends,junctionbox,elbows,screwsatan interval of 300 mm as required. 25 mm PWD Ele SR 2-23-24 Page No. ...
Copper Multi Strand Wire Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of...
MCB distribution boards Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacit...
Plastic Plate Supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws. 110 mm PWD Ele SR 2-23-24 Page No. 9 IItem code 3.14.6
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
57518.doc
Tender Document • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .