| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC DHARGLOON MENDHAR | ₹1.2 Cr | L1 | Accepted-AOC l1 |
| 2 | L2₹1.4 Cr+₹15.7 L (12.8%)Rejected-AOC | ₹1.4 Cr+₹15.7 L (12.8%) | L2 | Rejected-AOC l2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive due to insufficient work experience |
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
16 Jan 2026, 6:00 pmClosed
Executive Engineer I and FC poonch
Office of the Executive Engineer I and FC poonch
Construction of Proposed Office Building for PHE Division Mendhar Including Irrigation Sub-Division Mendhar
2026_IFC_299680_1
e-NIT No.26 of 2025-26 Dated 02-01-2026
Open Tender
Civil Works
Percentage
mendhar
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,600
Yes
Executive Engineer I and FC poonch
₹3.5 L
Yes
Superintending Engineer Hydraulic Circle Poonch
7 May 2026
2 Jan 2026
17 Jan 2026
2 Jan 2026
16 Jan 2026
2 Jan 2026
12 Jan 2026
Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In lime mortar
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level wit 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and medium tensile steel bars
12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class deodar wood(35mm)thick
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :Second class deodar wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second class deodar wood
Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.100 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :100x10 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250x16 mm
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.
Applying priming coat:With ready mixed red oxide Zinc Chromate primer ofapproved brand and manufacture on steel galvanized iron/steel works
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 19.2.1 Internal work-exposed on wall with clamps at 1.00 meter spacing PN-16 pipe , 25mm OD(SDR-7.4)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 19.2.1 Internal work-exposed on wall with clamps at 1.00 meter spacin PN-16 pipe , 25mm OD(SDR-7.4)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
Grating (C.I.) 180x180 mm
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets 20 mm dia ( heavy type)
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with White P.V.C automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Range of two half stall urinals with 5 literP.V.C automatic flushing cistern.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms.
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 300 mm wide
carriage of sand 50 km by MT
carriage of aggregates 5 km by MT
carriage of brick 200 km by MT
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded
wiring for light point/fan point/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor singel core casbel in furface /recessed medum class pvc conduit with modular switch , modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper comnductor singel cabel etc as req.Group A
wiring for light\power plug with 2x4 sq. mm FRLS PVC insulated copper conductor singel core cabel in surface\recessed medum class PVC conduit aslong with 1 no. 4 sq. mm. PVC FRLS insulated copper conductor singel core cabel in for loop earthing as req.
wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req. 2x1.5 sq. mm +1x1. sq.mm earth wire
wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req. 2x2.5 sq.mm+1x2.5sq.mm earth wire
wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req 2x4.0sq.mm +1x 4.0 sq. mm rarth wire
wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req 2x6.0 sq. mm+1x6.0 sq. mmearth wire
wiring for cicuit/ submain wirring alongwith earth wire with the following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req 4X16 sq mm+2x 6.0 sq.mm earth wire
supply and drawing following size of FRLS PVC insulated copper conductor 'singel core cabel in surfacr/ recessed medum class PVC conduit as req. 1x1.5 sq. mm
supply and fixing of follo following size medum class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed comduit as req. 5/6 amp switch.
supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req 5/6 ampA switch
supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req 15/16 amp switch
supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req 3 pin 5/6 A socket outlet
supply and fixing following modular switch/socket on the exisitying modular plate & switch box including connections but excluding modular plste etc. as req 15/16 amp switch
supply and fixing two module steped type electronic fan regulator on exisiting modular plate switch box including connection bu excluding modular plate etc as req.
supply and fixing modular blanking plate on existing modular plate & switch box excluding switch box etc. as,req.
supply and fixing suitable G.I.box with modular plate and cover in front of surface or in recess, includijng providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and15/16 A modular switch,connection ,painting,etc as req
supply and fixing suiutable size of GI box with modular plate and cover in forent of surface or in recess,including providing and fixing 2 nos. 5/6 A modular socket outlet and 2 nos. 5/6 A modular swuitch, connection etc as rwq. (for light plug to be used in non residential buldings)
supply and fixing following size/module GI. box alongwith modular base & cover plate for modular switches in recessed etc.as req.1 or 2 module (75 mmx75mm)
supply and fixing following size/module GI. box alongwith modular base & cover plate for modular switches in recessed etc.as req 3 module (100mmx75mm)
supply and fixing following size/module GI. box alongwith modular base & cover plate for modular switches in recessed etc.as req 8 module(125mmx125mm)
supply and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, intreconnection, powder painted including earting etc. as req. ( but without MCB/RCCB/Isolator)6 way(4+18) Double Door
supply and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, intreconnection, powder painted including earting etc. as req. ( but without MCB/RCCB/Isolator) 6 way(4+18) Double Door
supply and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, intreconnection, powder painted including earting etc. as req. ( but without MCB/RCCB/Isolator) 8 way(4 +24) Double Door
supply and fixing 5 A to 32 A rating, 240/415 V, 10 KA, ''C'' curve ,miniature circuit breaker suitable for inductive load of following pole in exisiting MCB DB complete with connection, teasting and commessoning etc. as req.single pole
supply and fixing 5 A to 32 A rating, 240/415 V, 10 KA, ''C'' curve ,miniature circuit breaker suitable for inductive load of following pole in exisiting MCB DB complete with connection, teasting and commessoning etc. as req. single pole and neutral
supply and fixing rating, four pole 415 V isolator exisiting MCB DB complete with connection, teasting and commessoning etc. as req. 100amp
supply and fixing of following electrical items as req Fan Box
supply and fixing of following electrical items as req Fan sheet
supply and fixing of following electrical items as req A/B holder
supply and fixing of following electrical items as req LED lamp 9 watt
supply and fixing of following electrical items as req Deep box 25 sq mm Alum wire twin core
supply and fixing of following electrical items as req 25 sq mm Alum wire twin core
supply and fixing of following electrical items as req LED Bulkhead 9/12 Watt
25 sq mm Alum wire twin core
celling fan 1200mm swipe along with rod up to 2ft long as req
exhaust fan 300mm swipe
supply, installation , teasting and commessoning of 1.5 inverter type Ton split ACs (copper) (three star) hot & Cold (all weather)type of minimum capacity following size asdetailed below. each unit must provide cooling &dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. repairs made to wall ehereever erq. a) . Warrantee shall be provided for 12 month from the date of installation
Earthing with GI Earth pipe 4.5 mtr long 40mm dia including acessories andproviding mesonery enclouser with cover plate hasving locking arrangment and watering pipe (but wthout charcool/salt) etc as req.
supply, installation , teasting , commessoning of automatic voltage stablizer coppre wound wall mounted, singel phase with rangeof 90 -240 volt along with wall mounted brakes and fitting. the job inlluding he repairing the wall whare necessary warrantee 2 year from the date of installaion
providing and fixing of IP-20 Recessde/ surface mounted round / sqaure SMD mid power (15-18 watt)LED Downlight with power coated die-cast alum. housing with UV stabilized non yellowish Diffuser withBIS complience 2.5 KV surg protected isolated driver, with short and open circuit protection .having efficiency .85% system lumin efficacy of ≥110 lm/ Watt,THD< 10%, PF ≥ 0.95, Cri.80, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°k/6000°/6500°K(A per ANSI Bin) , maximum power consumption should not more then the specified rating and fixture shell be of BIS standard and teade mark certificate (T.C) Manufacture word Mark / Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &Lm80) certificate /report from OEM shall be submitted. all as per approved by EIC.
providing and fixing of IP-20 SMD mid powerLED batten type integrted light fixture made from power coatedExtruded alum. housing with in built driver, complience 2.5 KV surg protected isolated driver, with short and open circuit protection .having efficiency .85% system lumin efficacy of ≥110 lm/ Watt,THD< 10%, PF ≥ 0.95, Cri.80, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°k/6000°/6500°K(A per ANSI Bin) , maximum power consumption should not more then the specified rating and fixture shell be of BIS standard and teade mark certificate (T.C) Manufacture word Mark / Name Engraved/Embossing/Screen Printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &Lm80) certificate /report from OEM shall be submitted. all as per approved by EIC. 20/22 Watt LED 4 feet with min. lumen output (2000-2200) lm
supply and laying 1 no. PVC/XLPE insulated and PVC shealed /XLPE power cabel of 1.1 KV grade of following size in the exisiting RCC/Hume/DWC/Stone ware/metal pipe as req. 3.5 CX16sq. mm A2XFY
supply and laying 1 no. PVC/XLPE insulated and PVC shealed /XLPE power cabel of 1.1 KV grade of following size in the exisiting RCC/Hume/DWC/Stone ware/metal pipe as req. 3.5 CX50sq. mm A2XFY
supply and laying 1 no. PVC/XLPE insulated and PVC shealed /XLPE power cabel of 1.1 KV grade of following size in the exisiting RCC/Hume/DWC/Stone ware/metal pipe as req. 3.5 CX70sq. mm A2XFY
Supply, installation, testing and commissioning of inverter 2000/2300 VA along-with 2nos. long tubler batteries 200 AH and trolly of suitable size
Supply, Erecrtion of flang mounted 7.5/8 mtrs long hot dip galvanized octagonal pole of follwing hight made from 3 mm thick HT steel pole having top dia -70 mm and Bottom dia of 135 mm complete with average coating thickness of a least 65 micron . the galvanizing shell be done a singel dipping their shell not be any circumferental welding pole shell have door of approximate 300 mm length at minimum elevation of 500 mm from the base plate the door shall be vandel resistance and shell be weather proof ot ensure safety of inside connection . the door shell be flush with the exterior surface and shell hasving suitable locking arrangment pole shall have galvanized base plate of size 220 mmX220 mmX12mm thick with provision of hole for 4 nos. M 20 foundation boards with double nut and singel washer including supply and fixing the following in the window box provided for cabel terminated a)supply and fixing 6 mm thick laminated mounted sheet inside the window mounted and includeing earthing completebi GI pipe 40 mm or Gi Rod 20 mm 2.5 mtr long through GI strip supply and fixcing of 63 A terminal block, suitable for 10/16 Sq. mm conductor 04 nos. & shorting link. 05 no of din channel including providing and fixing of Din channel of suitable length, 01 no the exisiting laminated sheet c) supply and fixing of 6/10 A Sp MCB "C" curve 10 KA, 02 nos. Earth stud 02 nos. welded at suitable hight washer springs washer and nuts. the job includes RCC foundationof 1300 mm. (H) X600 mm X 600 mm size with 1:2:4complete with 12 mm dia M.S. bar for reinforcement alongwith centring and shuttering i/c supplying & fixing 600 mm long 16 mm dia J type G.I coated foundation bolt/ Anchor bolt with temptemplete suitable for 6.5 to 6.0 mtr octagonal pole complete with all accessories as requiresd to complete job d) supply and fixing of Double street Arm to pole for fixing LED street light
providing and fixing of Lk08, IP 66 procteted LED street light luminaire on exisiting bracket /pole fixture made of powdeer coated single peice presure die cast alum. metrial with heat dissipation fines of housngwi9th UV cover /Toughend glass cover and secondery lens of each led 7 shuld be SMD type of 3 to 5 watt eachthe system efficacy >=125 Lm/watt and poted driver 7 hass unique BIS R nunber w9ith input voltage AC 120 to 270 V AC with high voltage cutoff@>= 300V and auto resetting safety PF. >0.95 druiver efficiefency>85% Led street light fixture with minimum lumen output 1500 lm.
Supply, installation, testing and commissioning of inverter 1250 VA a long-with 1no. long tubular batteries 200 AH and trolly of suitable size
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.41 MB
Nit26.pdf
Tender Documents • 1.39 MB
DRAWING.pdf
Other Document • 0.31 MB
BOQ_972334.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .