| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
Closing Date
2 Mar 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Srinagar
Barbarshah Maisuma Srinagar
Internal Electrification Of 500 Bedded Paediatric Hospital Bemina with Respect To Its Internal Wiring ( Fourth Floor )
2021_PWDJK_118254_1
E/NIT/140/2020/21dtd 25/02/2021
Open Tender
Electrical Works
Item Rate
30 days
Internal Electrification Of 500 Bedded Paediatric
as per BOQ
7 documents required · 7 mandatory
₹800
Executive Engineer RNB Electric Division Srinagar
Exempted
2 Mar 2021
25 Feb 2021
2 Mar 2021
25 Feb 2021
2 Mar 2021
25 Feb 2021
120 days
Amount
Point wiring for switch controlled primary light points with 3x2.5 sq mm (P+N+E) FRL PVC insulated 660/1100 volt grade flexible stranded (50 strands of .25 mm dia.) copper conductor wires of Polycab / Havells / ALBA / Finolex make in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Legrand / L&T / Havells make and colour housed in zinc chromate passivated GI boxes with moulded cover plate and including cost of circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required ( Excl cost Of conduitng)
Point wiring for Call Bell points with 3x1.5 sq mm (P+N+E) FRL PVC insulated 660/1100 volt grade flexible stranded (50 strands of .25 mm dia.) copper conductor wires Polycab / Havells / ALBA / Finolex make in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp Bell Push of Legrand / L&T / Havells make and colour housed in zinc chromate passivated GI boxes with moulded cover plate and including cost of circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required ( Excl cost Of conduitng)
Point wiring for ceiling fan points with 3x2.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires Polycab / Havells / ALBA / Finolex make in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch and 240 volts 300 watt 5 step electronic speed regulator of Legrand / L&T / Havells make and colour housed in zinc chromate passivated GI boxes with moulded cover plate and with inter connections complete as per specification and as required. ( Excl cost of conduitng )
Point wiring for Exhaust fan points with 3x2.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires Polycab / Havells / ALBA / Finolex make in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Legrand / L&T / Havells make incl cost of 3 way ceiling rose near exhaust fan of approved quality and colour housed in zinc chromate passivated GI boxes with moulded cover plate and with inter connections complete as per specification and as required ( Excl cost of conduitng )
Wiring for 2 No's 6 Amp Socket out lets ( Two out let wired on one circuit ) for UPS with 3x2.5 sq mm FRLS PVC insulated copper conductor single core of Polycab / Havells / ALBA / Finolex make in recessed or surface PVC incl circuit wiring from DB to first Point with 2 no 240 volts 6 amp 3 pin socket out let along with 240 volt 6 Amp control Switch with modular grid plate flush mounted Legrand / L&T / Havells make and colour housed in zinc chromate passivated MS boxes with moulded cover plate and inter connections complete as per specifications and as required. ( Excl cost of conduitng ) Long Points
Wiring for 16 Amp Socket out lets ( Two out let wired on one circuit ) with 3x4 sq mm (P+N+E) FRLS PVC insulated copper conductor wires Polycab / Havells / ALBA / Finolex make in recessed or surface PVC Conduit with 1 no 240 volts 16 amp 5 pin socket out let along with 240 volt 16 Amp control Switch with indicator of Legrand / L&T / Havells make and colour housed in zinc chromate passivated GI boxes with moulded cover plate and inter connections complete as per specifications and as required.( Excl cost of conduit ) Long Points
Supplying and fixing of following sizes of PVC Hard Grade Conduit of standard make along with accessories in surface fitted with saddles / recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm dia
38 mm dia
DISTRIBUTION BOARDS :
Supply, installation, testing and commissioning of following way, single pole and neutral, sheet steel, Ip - 43 MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including Earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way Double Door of Legrand / Hager / L&T / Havells / ABB make
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, I -43 MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including Earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (8 + 12), Double door of Legrand / Hager / L&T / Havells / ABB make
Supplying and fixing following way, surface/recess mounting vertical type 415V TPN Ip-43 MCB distribution board of sheet steel dust protected duly power painted incomer of 200A ,tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCB and incomer) as required. of Legrand / Hager / L&T / Havells / ABB make
8way (8+24) Doiuble Door with Incomer TPN MCB and out Goiung SP/TP MCB`s
12way (8+36) Double Door With Incomer TPN MCCB and Out Going SP/TP MCB`s
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Legrand / Hager / L&T / Havells / ABB make
Single pole
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Legrand / Hager / L&T / Havells / ABB make 40-63A TPN MCB
Providing and fixing following rating and breaking capacity following pole MCCB with thermal release complete with spreader links, phase barrier etc in existing MCB DB complete with connections, testing and commissioning etc as required of Legrand / Hager / L&T / Havells / ABB make 160A TPN MCCB 36KA
M/S FALAH ENTERPRISES
M/S PEARL ENTERPRISES
stage.html
html • 0.02 MB
finance_227061.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .