Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹33.4 L+₹4.6 L (15.9%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | Rejected-Technical 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | - | Rejected-Technical not addmitted due to not enlisted in appropriate category |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Mar 2024, 6:00 pmClosed
GE South Pune
GE South Pune
8512REPAIR REPLACEMENT MAINTENANCE AND SERVICING TO SUMMER APPLIANCES AIR CONDITIONER DESERT COOLER AND WALK-IN-COOLER WATER COOLER AND OTHER CONNECTED WORK IN AICTS CH COMPLEX MITSD SHO AREA AND OTHER CONNECTED AREA UNDER AGE E/M-I OF GE SOUTH PUNE
2024_MES_642763_1
8512/E8 GE SOUTH
Open Tender
Civil Works
Item Rate
270 days
GE South Pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE South Pune
₹90,000
Yes
30 Mar 2024
16 Feb 2024
18 Mar 2024
16 Feb 2024
16 Mar 2024
4 Mar 2024
Amount
S&F in replacement fan / blower motor suitable for window type AC, double shaft single / double speed, single phase, 230 V, AC of 1/4 HP capacity as required at site, making suitable fixing arrangement at existing place (as per sample) including taking down old unserviceable, complete all as directed by Engr-in-charge
All as per Srl item No. 2 here-in-before but capacity 1/5 HP, complete all as directed by Engr-in-charge
All as per Srl item No. 2 here-in-before but capacity 1/6 HP, complete all as directed by Engr-in-charge
S&F fan blade (As per sample) in replacement suitable for window type AC / split type AC / Desert Cooler of any capacity, complete all as directed.
S&F in replacement starting capacitor of following capacities as per sample including taking down old unserviceable, complete all as directed by Engr-in-charge:- (a). Starting capacitor 40 to 60 MFD
(b) Starting capacitor 60 to 80 MFD
(c) Starting capacitor 80 - 100 MFD
(d) Starting capacitor 100 - 120 MFD
S&F in repair running capacitor of following capacities as per sample including taking down old unserviceable, complete all as directed by Engr-in-charge:- (a). Running capacitor 10/15/25 MFD
(b) Running capacitor 36 MFD
(c) Running capacitor 45 MFD
(d) Running capacitor 55-60 MFD
S&F in repair thermostate complete suitable for window & split AC, as per smple including taking down old unserviceable thermostate, complete all as directed.
M&L in replacement of air filter made out of nylon wire mesh moulded in plastic, same as per old existing filter's size and shape suitable for 1.5/2 TR capacity of split type AC, complete all as directed.
S & F in repair cooling coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable cooling coil, complete all as directed.
S & F in repair cooling coil assembly suitable for any Make & any model of window AC complete including taking down of old unserviceable cooling coil, complete all as directed.
S & F in repair condenser coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable condenser coil assembly, complete all as directed.
S & F in repair Condenser coil assembly suitable for any Make & any model of window AC complete including taking down of old unserviceable condenser coil assembly, complete all as directed.
S & F in repair wiring kit suitable for split AC & window AC including taking down of old unserviceable wiring kit, complete all as directed
M&L in replacement of broken / damaged front grill assembly complete suitable for existing model of window AC of any capacity complete all as directed.
S&F in replacement single shaft blower motor of 1/6, 1/8, 1/5 HP capacity suitable for split type AC of capacity 1.5/2 TR / Air curtain of any size complete as directed by Engineer-in-Charge
S&F in replacement swing motor suitable for split AC (as per sample) including taking down of old unserviceable swing motor, complete all as directed.
S&F in replacement of electronic circuit plate (PCB) including necessary repairs to electronic circuit of remote operation suitable for 1.5 / 2.0 ton split type AC for any type complete all as directed.
S&F in replacement of remote with stand suitable for 1.5 / 2 ton split type AC operation for any make complete all as directed.
S&F in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC, complete all as directed
S&F in repairs single pole contactor of existing model and size suitable for 1.5 TR split type AC as per sample, complete all as directed.
S&F in repairs 3 pole power contactor 25 Amp, 220V AC suitable for 2 TR split type AC, as per sample, complete all as directed.
Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 1.5 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 2 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 1.5 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 2 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
M&L for replacement of copper tubing, confirming to relevant IS, 5/8" and 3/8" flare size, or nearest size, 3 core 2.5sqmm copper cable including PVC drain pipe and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge.
S&F in replacement of service valve of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity complete all as directed.
S&F in replacement brass flare nut of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity, complete all as directed.
M&L for taking out old broken drain outlet pipe of any type attached to indoor unit of split type AC & S & F new drain outlet PVC pipe of 20mm dia from indoor unit to nearest suitable drain outlet suitable for split type AC of any capacity complete all as directed by Engineer-in-charge
S & F in replacement factory made angle iron stand suitable for outdoor unit of split type ACs of any capacity complete all as directed.
Labour for shifting of split AC 1.5 , 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of New location indoor / outdoor unit complete with and incluidng Gas charging with suitable type of gas, tested on full load on summer season complete all as specified and as directed. Note :- Copper tubing, PVC pipe etc shall be measured and paid saparetly.
S&F starting relay with OLP kit suitable for any Make any model refrigerator including with testing and commissioning complete all as specified and as directed.
S&F in replacement of thermostat switch suitable for any model of refrigerator complete all as specified and as directed
S&F electric Lamp 15 watt, 230 volt AC, thread / pin type suitable for any Make & capacity of refrigerator complete all as specified and as directed
S&F in replacement of lamp holder suitable for any Make& capacity / model of refrigerator complete all as specified and as directed
S&F in replacement of door switch push type suitable for any Make & capacity or model of refrigerator complete all as specified and as directed
S&F in replacement of broken / damaged freezer door complete with casing and lock nut as per sample suitable for existing refrigerators of any capacity, complete all as directed.
S&F in replacement of vegetable tray complete suitable for existing model of refrigrators of any capacity, complete all as directed.
S&F door handle suitable for Refrigerators of any Make & model / any capacity, complete all as directed.
S&F PVC bottle guard suitable for 165 to 310 Ltr Refrigerators suitable for any Make & model / any capacity, complete all as directed.
S&F in replacement of chiller tray suitable for existing model of refrigerators of any make & capacity, complete all as directed.
S&F in replacement of metal shelf powder coated suitable for existing model of refrigerator of any make & capacity, complete all as directed.
S&F in replacement of cooling coil suitable for existing models of refirigerators of following capacity, complete all as directed:- (a). Refrigerator of capacity 165 / 170 / 175 / 180 Ltrs
(b) Refrigerator of capacity 192/210 Ltrs
(c) Refrigerator of capacity 300/320 Ltrs
S&F in replacement of condensor suitable for existing model of refirigerators of the following capacity, complete all as directed:- (a). Refrigerator of capacity 165 / 170 / 175 / 180 Ltrs
(b) Refrigerator of capacity 192/210 Ltrs
(c) Refrigerator of capacity 300/320 Ltrs
S&F in replacement of PVC gasket magnetic type suitable for any Make & any model / any capacity of refrigerators complete, complete all as directed.
S&F in replacement of condenser fan motor, single shaft 1/35, HP capacity, single phase, 230 VAC suitable for water cooler, complete all as directed.
S&F in replacement condenser fan motor, single shaft 1/83 HP capacity, single phase, 230 V , AC suitable for water cooler, complete all as directed.
S&F in replacement of condenser fan motor, single shaft 1/10 HP capacity, single phase, 230 V , AC suitable for water cooler, complete all as directed.
S&F plastic ice cube tray, complete all as directed.
S&F in replacement toughened glass partition / shelves suitable for any capacity or any Make & any model, complete all as directed.
S&F in replacement of timer switch suitable for any Make & any model /any capacity of refrigerator, complete all as directed
M&L for painting to refrigerator of 310 / 300 / 316 / 165 Ltr capacity by scraping the old painted surfaces and making smooth surfaces and applying two coats of synthetic enamel paint (of approved colour) over a coat of red oxide primer including writing SM Nos. etc complete all as specified and as directed
M&L for cleaning of water cooler’s tank by from inner side and washed with soda / Acid and de-scaling by brushing and stop leakage (if any) from water tank by soldering / welding and make water tank leak proof and complete all as specified and as directed
M&L for disconnecting the water cooler of any capacity from electric and water connections and cleaning the condenser unit & fins by using carbon tetra chloride cleaning agent, oiling / greasing of fan motor, checking of alignment of motor, cleaning of water storage tank and re-fixing back the same and testing for its smooth functioning complete all as directed by Eng-in-charge.
M&L for preparation of old surfaces of water cooler of any capacity and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray gun machine including writing cooler number with black paint, complete all as specified and as directed
S&F in replacement 15mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 142 gms), complete all as specified and directed.
S&F PVC pipe flexible type 32 mm dia suitable for waste water draining complete all as specified and as directed
S&F in replacement over load protector relay (OLP) suitable for water cooler of any capacity complete all as specified and as directed
S&F in replacement self closing push tap, 15mm bore, brass chromium plated, long body, inner threaded complete all as specified and as directed.
S&F in replacement aluminium blade suitable for blower motor of water cooler of 80 to 150 Ltrs capacity, complete all as specified and as directed
S&F in replacement relay suitable for water cooler of any capacity and make complete all as specified and as directed
S&F in replacement thermostate suitable for water cooler of any type & capacity complete all as specified and as directed
S&F in replacement of blower motor 1/32 HP, 230 volt suitable for 60 to 150 ltrs capacity water cooler complete with base frame and rubber bush complete all as specified and as directed
S&F in replacement drip tray made of stainless steel suitable for 40 to 150 ltr capacity water cooler any Make complete all as specified and as directed
S&F water tank gasket suitable for water cooler of 40/80 Ltr capacity complete all as specified and as directed
S&F in replacement wiring kit complete for water cooler complete all as specified and as directed
S&F in replacement cooling coil assembly suitable for any Make & model of water cooler including taking down old unserviceable, complete all as directed.
S&F in replacement condenser coil assembly suitable for any Make & any model of water cooler complete including taking down old unserviceable, complete all as directed.
S&F in replacement of corroded bottom portion suitable for water cooler of any make & capacity with MS angle iron of suitable size as per existing, including necessary welding / brazing with mild steel sheet of 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engineer-in-charge
M&L for servicing of deep freezer unit completely and ensure its smooth functioning and satisfactory performance by means of cleaning each part of the machine carefully, greasing / oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and air pressure through blower, complete all as directed by Engr-in-charge
S & F in replacement of condenser coil suitable for deep freezer of any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of evaporator of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of d-frost heater of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of d-frost timer of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of top spring loaded hinge of deep freezer of any make and capacity including taking down old unserviceable, complete all as directed.
M&L for servicing / repairing of desert cooler's fan by disconnecting from desert cooler with and including cleaning of water water tank by using wire brush and sand papering the surfaces, greasing & oiling of all moveable parts, stop water leakages (If any) from water tank by welding or by using M'seal and make it leak proof and finally applying two coats of synthetic enameled paint on hole body (inner & outer side) of desert cooler, re-assembled the same & fixed it's in original position including replacement of unserviceable spares, complete all as specified and directed by ENgr-in-charge. Note:- Spare parts will be measured and paid separately under respective item sof BOQ as "Supply only".
Supply only desert cooler fan motor with copper wounded of existing capacities & make complete all as specified and as directed
S&F in replacement of capacitor 4 mfd suitable for fan Kit / Exhaust fan complete all as specified and as directed
S&F in replacement of PVC water distributer junction 3 way / 4 way suitable for desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of PVC elbow suitable for desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of PVC flexible pipe, 15 mm dia, suitable for water distribution system to desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of front grill plastic type suitable for desert cooler with necessary nut, bolts, and washers etc, complete all as specified and as directed.
S&F in replacement of vertical lifting pumps 1/70 HP, 230 Volts single phase complete all as specified and as directed
S&F in replacement of submersible pump suitable for desert cooler / industrial cooler complete upto 4000 cum complete all as specified and as directed
S&F in replacement of submersible pump, suitable for cooler of any type of capacity 6000 cum complete all as specified and as directed
S&F in replacement of wood wool padding of desert cooler of suitable size including with wire net, weight not less than 450 gms in each panel complete all as specified and as directed
S&F in replacement side shutters for desert cooler, as per sample, made from 22 gauge PGI sheet grill type complete all as specified and as directed.
S&F in replacement copper wounded AC electric motor suitable for industrial desert cooler, single phase, 240 volts, AC, heavy duty, capable for 6000 cum air flow, complete all as specified and as directed
S&F in replacement of metallic fan blade suitable for desert cooler's motor 4000 Cum air flow complete all as directed
S&F in replacement of metallic fan blade suitable for industrial desert cooler's motor 6000 Cum air flow, complete all as directed
S&F in replacement of following type sealed compressor unit of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge for the following capacities:- (a) Compressor suitable for refrigerator of capacity 165/170/175/180 Ltrs.
(b) Compressor suitable for refrigerator of capacity 192/210 Ltrs
(c) Compressor suitable for refrigerator of capacity 300/320/360 Ltrs
(d) Compressor suitable for water cooler of capacity 40/80 Ltrs
(e) Compressor suitable for water cooler of capacity 60/120 Ltrs
(f) Compressor suitable for water cooler of capacity 150 Ltrs
(g) Compressor suitable for deep freezer of capacity 320/400 Ltrs
(h) Compressor suitable for Window type & split type AC of capacity 1.5 TR
(i) Compressor suitable for window type & split type AC of capacity 2 TR
(j) Compressor suitable for Split type / Tower AC of capacity 2.5 to 3 TR, 3 phase 440 VAC
M&L for gas charging with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning for the followings:- (a) Refrigerator of any capacity & make
(b) Water cooler of any capacity & make
(c) Deep Freezer of any capacity & make
(d) Window type AC of 1.5/2 TR capacity
(e)Split type AC of 1.5/2 TR capacity
(f) Split type AC/Tower AC of 2.5TR capacity
S&F in replacement of indoor discharge fan 10 inch size, suitable for walk-in cooler complete all as directed by Enginner-in-charge.
Taking out the unserviceable sealed compressor unit from the Walk in cooler of any make & capacity by means of cutting to suction & discharge pipe line, disconnecting from electric supply, foundation nut bolts, etc and keeping aside as directed and supply and fixing new sealed compressor unit of existing make and capacity, complete all as directed by Engineer-in-Charge.
S&F in replacement of HP/LP cut off, KP-15 Make - Danfoss / Indfoss suitable for Walk-in-Cooler of any type, complete all as directed by Engineer-in-Charge.
S&F in replacement Drier filter of 5/8", 3/8", 1/2" flare size or other nearest flare size Make - Sporlon / Catchall or equivalent, complete all as directed by Engineer-in-Charge.
S & F in replacement of Digital Sub-zero thermostate suitable for the cold storage & programe the thermostat for auto cut-off including all wiring complete all as directed by Engineer-in-Charge.
M & L for Vacuumising the complete system of walk-in cooler with double stage vacuum pump of 2kg/cm2 with and including charging with nitrogen gas up to 250-300 PSI the complete system and check for leak testing and maintaining the pressure for 24 hrs and rectifying the leakage if any in the system and after that charging the system with F-22 gas with required quantity, complete all as directed by Engineer-in-Charge.
S&F in replacement voltage stabilizer 5 KVA, copper winded complete all as specified and as directed.
S&F in replacement voltage stabilizer 2 KVA, copper winded complete all as specified and as directed.
S&F in replacement voltage stabilizer 1.5 KVA, copper winded complete all as specified and as directed.
S&F in replacement voltage stabilizer 0.5 KVA, copper winded complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note :- One meter of PVC casing caping along with two runs of 4 Sqmm wire and one run of 2.5 Sqmm earth wire shall be measured as one unit length
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole, 20 Amp MCB-01 No., 240 volt, complete all as specified and directed.
S&F in replacement MCB, SPN, 40 Amps,10 KA, 230 V, 'C' series complete all as specified and directed.
S&F in replacement cable PVC insulated, 3 core 2.5 Sqmm with stranded copper conductor, 1100V grade from socket / switch to geyser, complete all as specified and as directed.
S&F in replacement cable PVC insulated, 3 core 1.5 Sqmm with stranded copper conductor, 1100V grade from socket / switch to geyser, complete all as specified and as directed.
S & F in replacement cooler stand made from suitable size mild steel angle iron of existing size and shape, suitable for PVC desert cooler including taking down old unserviceable, complete all as directed by Engr-in-charge.
S & F in replacement 5 Amp pin top, complete all as directed by Engr-in-charge.
S & F in replacement 15 Amp pin top, complete all as directed by Engr-in-charge.
GRID SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .