Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.9 L+₹37,600 (3.28%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
10 Jul 2023, 5:00 pmClosed
Executive Engineer
EE WSS Division No.1 Tarn Taran
Providing and Installing deep tubewell 200 mm i/d straight 145 mtr depth with 20 mtr stainless strainer with hand boring, Depth 145 mtr, Pumping machinery, Chlorinator, PVC rising main, sluice vales, etc. complete in all respect
2023_WSS_105063_1
Letter No. 3199 dated 26.6.23 Tw Above 10 Lakh
Open Tender
Civil Works
Item Rate
90 days
Tarn Taran
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹23,000
Yes
27 Dec 2023
30 Jun 2023
11 Jul 2023
30 Jun 2023
10 Jul 2023
30 Jun 2023
Amount
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tubewellis lowered & tested, equipment as required such as hand boring machine and its accessory,transportationto site and vice versa etc. complete in all respect.
(c) Boring with 250mm id Housing Pipe 0 to 150 m
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
(d) 200 mm nominal diameter (weight 33.6 kg per meter) 6.4 mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
(i) 200 mm steel starainer (slot size 0.15mm) 6.30 mm thick
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
(c) 200 mm internal diameter
Supplying, Lowering & fixing of stainless steel socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into T/Well bore complete in all respect.
( b)200 mm i/d
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Supplying and fixing well cap having thread to fix on housing pipe complete in all respect
(c) 200 mm internal diameter
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
(c) 200mm internal diameter (weight 33.6 kg per meter) 6.4 mm thickness
Supplying & fixing of M.S. Clamp of size 200mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
(a) Capacity of Air compressor 300 cfm at 250 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Providing for santary clay seal (as per BIS code IS 2500-2019 including sterlization of T/W
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications
110mm o/d pipe of 10 Kg/cm2 lines laid complete
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department size 0.6m x 0.6m Including Carriage
C.I FITTING OUTSIDE PUMP CHAMBER Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 549 LPM against a head of 63 mtr along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including G.I. Column Pipe of suitable size 100 mm =36 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (reputed make) complete in all respects as per standard Specifications. Note:- Rate Excluding the cost of old machinery)
Cost of pumping set 549 LPM Head 63 mtr.)
Cost of lowering (with length) G.I Column Pipe 100 mm i/d
Cost of submersible cable (with length) 4.00mm2 3 core
Cost of pannel board
NARINDER SINGH GOVT. CONTRACTOR PATTI
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .