| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹85,852.50 (3.67%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹27.0 L+₹3.6 L (15.4%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
PERIODICAL SERVICES AND REPAIR/MAINT OF PLASTERING, ROOFING AND JOINERY AT AH COLONY PRE MAP ACCN AT MIL STN SGNR
2024_MES_649525_1
GE SGNR/TOK-06 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
Sri Ganganagar(Raj)
D Class a(i) and for un-enlisted, refer NIT para 8
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹70,000
Yes
24 May 2024
6 Apr 2024
6 May 2024
6 Apr 2024
4 May 2024
20 Apr 2024
Amount
Demolition of RCC , chajjas, Beam, Parapet and similar suspended works complete all as specified and directed by Engineer - in - Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer - in - Charge.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in CM 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
M&L half brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in CM 1:4 etc.complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster on brick or concrete surfaces of wall/ ceiling including racking out joints, hacking for keys scrubbing down with water complete all as specified directed by Engr-in-Charge.
M&L 15mm thick, rendering in cement mortar 1:6 to brick/concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick, rendering in cement mortar CM 1:4 to brick/concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 5mm thick, rendering in cement mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M & L for flush pointing in CM 1:4, to bricks laid flat or brick edge on ,roofs of MAP Ph-I Bldgs having height upto 12.0 mtr complete all as specified and directed by Engineer - in - Charge.
M&L 10 mm thick, rendering in cement mortar CM 1:3 to work in isolated widths or in widths not forming part of general plastering such as brick/concrete faces of chajjas,facia,window jambs,sunshade and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for fixing of GI wire netting 0.90 mm dia and 12mm mesh lathing by means of fasteners of requierd length and spacing beetween fasterners is 300mm centre to centre both way to concrete surface etc,in walls,ceilings,stanchions,beams,etc including all laps,cutting and waste etc complete all as specified and directed by Engineer-in- charge
M&L for 5 mm thick one layer of cement : Coarse sand (1:2) over fixed GI wire netting making good after that rendering 5 mm thick in cement mortar in 1:3 on ceiling complete all as specified and directed by Engineer - in - Charge.
M&L for prepration of New plastered Internal wall surface complete applying the following :- (a) Applying 1.5mm thick wall care putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified (b) Applying a coat of primer by usingRoller over putty (c) Applying two coat of Acrylic Emulsion distemper by using Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge
M&L for prepration of New plastered Internal wall surface complete applying the following :- (a) Applying 1.5mm thick wall care putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified (b) Applying a coat of primer by using Brush / Roller over putty (c) Applying two coat of Premium exterior acrylic emulsion Apex paint by using Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge
M&L for applying two coat of white wash on New plastered ceiling surface to make the surface even and smooth etc complete all as specified and directed by Engineer - in - Charge.
M&L for prepration of old plastered Internal wall surface complete applying the following :- (a) Applying 1.5mm thick wall care putty on wall surfaceonly where for filling depression of surface and nail holes to making even surface. (b) Applying one coat of Acrylic Emulsion distemper (incl & up to G+3 floor Qtr) using Roller complete all as specified and directed by engineer in charge.
M&L for applying one coat of white wash on old decorated surface of ceiling to make the surface even and smooth etc complete all as specified and directed by Engineer - in - Charge.
M&L for complete removal of existing treatment & washing the surface with pressure water on old External/internal wall surface complete all as specified and directed by engineer in charge. Note:- Scraping will be done by mechanical means
M&L for applying two coat of wall care putty on 0.3mm thick wall suface as per application (a) Applying one coat of wall putty 1.5mm thick on cleaned surface after that grind the surface and clean the surface with broom and prepare the surface for second coat. (b) Applying 2nd coat of putty 1.5mm thck complete all as specified and directed by engineer in charge.
M&L for applying one coat of primer on prepared surface using roller complete all as specified and directed by engineer in charge
M & L for applying Two coats of 100% Premium acrylic emulsion exterior paint Apex over Prepared surfaces complete all as specified and directed by engineer in charge.
M&L one coat of white wash on old decorated plastered or un-plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work etc complete all as specified and directed by Engineer - in - Charge.
M&L for Writing letters or figures with fluorecent paint ( Block. Roman, Italic or Indian) n exc. 30 cm high etc complete all as specified and directed by Engineer - in - Charge.
M&L Complete removal and Preparation of existing surfaces and applying two coat of cement base paint over a coat of primer on old decorated plastered surface of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete. All as specified and directyed by engineer in charge
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed by Engineer - in - Charge.
S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed by Engineer - in - Charge.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in - Charge.
Ditto- but refixing 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in - Charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting as in overflow pipe and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed by Engineer - in - Charge.
Taking down and Refixing old 500 Ltrs capacity Rotational moulded polyethylen water storage tank after cleaning and removing all scale and dirt etc from tanks and from mouths of cirulating pipes etc complete all as specified and directed by Engineer - in - Charge.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks triple layered(white coloured) (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down of Old PVC Tank complete all as specified and directed by Engineer - in - Charge.
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
S&F in repair 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where complete all as specified and directed by Engineer - in - Charge.
M&L for cement concerete 1:2:4 (20 mm graded aggrigate) as in filling and mass concerete as in roof padding etc complete all as specified and dirceted by Engineer-In-Charge.
M & L for cleaning of old Roof wall/ concrete surfaces & applied a coat of bituminous primer over cleaned surface @ 0.40 Kg/Sqm followed by a covering coat of Paving bitumen 85/25 grade 1.2 Kg/Sqm. APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed by Engineer - in - Charge.
M & L 40mm thick brick tiles bedded in 15 mm thick cement mortar (1:6) ,ar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by engineer in charge
M & L 40mm thick brick tiles retrived from dismantling of brick tiles(old tiles) bedded in 15 mm thick cement mortar (1:6) ,ar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by engineer in charge
Carefully chipping, removing existing loose/ damaged concrete with plaster from Columns by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower and removing/disposal of rubbish outside MoD land complete all as specified and as directed. (Hard concrete should not be removed by force).Height upto and including 4th floor complete all as specified and as directed by Engineer-in-charge
Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element/ brickwork including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and as directed by Engineer-in-charge.
Grouting, injecting two part, low viscosity, moisture insensitive injection liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost complete all as specified and as directed by Engineer-in-charge.Height upto and including 4th floor complete all as specified and directed by Engineer - in - Charge. Note :- Mode of measurement: per kg of material consumed Make: Sika - SikaDur 52 LP/ Fosroc- Conbextra EP 10/ Pidilite Dr Fixit Epoxy Injection Grout or equivalent make approved by GE in writing from E-in-Cs Br approved list.Height upto and including 4th floor
M&L for Mild steel work as ISMB,joists channel,angle or tee section fixed adjacent to ceiling and embedding in floor and brickwork including cutting welding and the like including caps.bases,splices etc,built from one or more beam or channel section or angle with plates including all lattice bars, stiffeners,gusset plates including necessary welding,rivetting etc.confirming to Fe 410 (Gde E-250) quality A etc complete all as specified and directed by Engineer-in-charge.
Shotcreting average thickness 25mm in RCC columns, beams and slab etc. (with mix minimum cement content of 350 Kg per Cum, M-25). Concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregates of 6mm to 10mm size in proportion as per design criteria) incl the cost of centering and shuttering at edges and corner etc as directed by Engr-in-Charge incl chipping of unsound/week concrete material 25mm average thickness from slabs, beams/columns etc with mannual Chisel or standard power driven percussion type all of approved makes incl tapering of all edges, making square shoulder of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and throughly washing with water and allowing it to dry etc incl removel of rust by applying approved rust remover chemical and the coating with Dr Fixit Epoxy zinc primer @ 6 Sqm per Litre at DFT of 100 micron as per manufacturer's instruction and specification, including removing rubbish material from building and thrown in low lying empty area at any distance from the site as directed complete as specified and as directed by Engineer-in-Charge. Note : Complete treatment to be executed by approved applicator.
Supply and fixing hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools and plants incl welding/L-clip/tying with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer - in - Charge.
Note :(i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
PAREEK AND COMPANY
Dashmesh Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .