Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.4 LAccepted-AOC NO 7 V V KOIL STREET OPP TO MEPZ TAMBARAM SANATORIUM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | L2₹88.4 L+₹1.1 L (1.21%)Rejected-AOC NO 2 21 MAPPEDU VILLAGE POST THIRUVALLUR TALUK THIRUVALLUR DISTRICT 631 402 | THIRUVALLUR | TAMIL NADU | 631402 | L2 | Rejected-AOC High rate tenderer | |
| 3 | L3₹96.2 L+₹8.8 L (10.1%)Rejected-AOC | L3 | Rejected-AOC High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹62,100
Closing Date
22 Oct 2024, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Construction of Building for Office of the Assistant Commissioner of Police, Redhills at Sholavaram in Thiruvallur District.
2024_TNPHC_493738_1
SE/CC/DB/2162/2024
Open Tender
Civil Works
Lump-sum
330 days
Sholavaram in Thiruvallur District
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹62,100
26 Nov 2024
15 Oct 2024
24 Oct 2024
15 Oct 2024
22 Oct 2024
15 Oct 2024
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 m
13.1) Filling with Excavated Earth
21.2) Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3) Supplying and fixing of Magnetic door catches
25) M.S.Holdfast
31) Weathering course
37.1) White washing 3 coats (slaked)
39) M.S Grills
40) Painting - New "wood work"
41) Painting - New "iron work"
46) Supplying and fixing of 20 mm dia Alu. Hanger Rod
47) Supplying and fixing of Alu Towel rail 75 cm long
48) Supplying and fixing of 5 pin Coat stand
49) Supplying and fixing of chromium plated 8 guage Picture Hook
50.3) Supply and planting avenue trees
50.4) Providing Tree guard
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 a. 32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
b. 25 mm dia
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
Electrical arrangemnt 69) Supplying and fixing 15Amps 3 pin plug type socket on a suitable MS box 16g
72) Supply and fixing of best approved superior variety concealed type Fibre box with M.S. Fan Hook
74) Charges for assembling and fixing of ceiling fan
76) Supplying and laying of 8SWG GI wire on wall below ground levels
78) Providing Earthing station using pipe electrode as per IS 3043 using 2.5m of 40mm and 1.0 m of 20mm B-class GI pipe(Type I)
86) Providing pre-constructional Antitermite treatment
112) S & F of Exsaust Fan 300 mm dia
Annexure 2.15) Supplying and filling stone dust
2.18) Supplying and filling with Quarry Rubbish
3.1.3) C.C.1:5:10 for Foundation & Basement
6.2.2) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
8.2.4.1) Standardised concrete Mix M25 Grade Concrete a. In Foundation and basement
b. Stilt / Ground Floor
c. In First Floor
d. In Second Floor
9.2.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a. In Ground Floor/Stilt floor
b. In First Floor
c. In Second Floor
10.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) b. In Ground Floor/stilt floor
c. In First Floor
d. In Second Floor
11.2.2) Brick work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) a. In Ground Floor
b. In First Floor
12.1.2) Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick a. In Ground Floor
b. In First Floor
14.I.I)Precast Cupboard slab 20 mm tk.using standardised concrete mix M25 a. In Ground floor
b. In First floor
14.I.II) Precast cupboard slab 40 mm tkusing standardised concrete mix M25 a. In Foundation & basement
b. In Stilt / Ground Floor
c. In First floor
18.1) Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam, Raft beam, Raft slab etc.,
b.Plain surfaces such as Roof slab, floorslab, Beams, lintels, lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.5.2.2) Supply and Fixing Soild UPVC door Shutter with frame
21.7.3) Supplying and fixing of Solid Core Flush door Shutters with teakply on both side with teakwood lipping alround 35mm thick a) 1000x2100mm (single leaf)
b. door size 0.900 m x 2.100 (Single Leaf)
22.1) T.W.Panelled door with aluminium fittings & brass screws only a)1000X2100mm.(Single leaf)
22.1.8) Supplying and fixing of Best Indian Teakwood Panelled door shutters Single leaf a. 1200X2100mm.without aluminium fittings (Single leaf)
22.3.3) T.W. frame & TW styles & rails with BWR double leaf shutters for cup board/ ward robes including two coat enamel paint & one coat primer.
22.6.5) Supplying and fixing of best Indian Teak wood openable French window of following size Franch window shutters of size 1.50 X 2.0M (2 bay openable )
26.1) Flooring in C.C.1:5:10
28.1)Floor plastering in C.M. 1:4, 20 mm tk.
29.8.1) Glazed tiles using Grout (Tile Joint Filler), C.M 1:2, 10mm tk
29.9.1) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound
33.2.1) Plastering in C.M. 1:5, 12 mm tk.
34.2.1) Plastering in C.M. 1:4, 12 mm tk.
35.2.1) Spl. Ceiling plastering in C.M. 1:3, 10 mm tk.
36.1) Cement mortar Border in C.M. 1:5, 12 mm tk. a. 150 mm wide
b. 75 mm wide
38.6) One coat white cement for new walls and other similar works.
38.8) Two coat of OBD over one coat white cement for inner walls
43.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.3) Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M25)
b) Augering 30cm dia
44.6) Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992- type 'A' for Rain water down fall pipe
50.5.1) Supplying. Fabricating and erection of M.S Scheme Name board
51.2) Supply and fixing of 1000 liters capacity HDPE water tank
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 c. 50mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
52.4) Supply ,laying & jointing the following pipes as per ASTM D 1785 of schedule 40 with PVC Specials (fully consealed in walls) c. 20mm dia PVC water supply ASTM pipe
53.5) Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1) Supplying and fixing of of 15mm dia half turn CP long body tap
54.2.1) Supplying and fixing of of 15mm dia half turn CP short body tap
56.3.1) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
56.4.1) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than G.F.
57.1.2) Supplying and fixing of of E.W.C.(White) 500 mm with "P" or "S" TRAP with double flapped seat & seat cover
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4) Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1) Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm
60.1) PVC Nahani trap (4way/2way)
61.3) UPVC Non Pressure pipe of SN8 SDR 34 ( S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1) PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
62.2.1) PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point
66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places
70.5.2) Supply and fixing of 4' long 18 W Crystal Glass LED tube Light with fitting
71.2) Supplying and fixing of 32 AMPS Triple pole main switch
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.8) Supplying and fixing 3 no of 32 Amps 500 volts grade porcelain fuse unit
80.2) Supplying and fixing of 1 no of 450x375x20mm thick TW plank
82.3.1)Supply and fixing of LED Street lighting luminaries suitable for fixing 30 watts LED lamp
84.3) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
85.1) Supply of G.I pipe 40mm dia 'B' Class
87.1) Supplying and delivery of Three phase ELCB/RCCB
93.1) Plastering with CM 1:3, 12mm with WPC
98.5.1) TW double leaves shutter with Brass Fittings b. 1500X2100mm.with Brass fittings (Double leaf)
105.1) Run off 4 wires of 4 Sq mm. PVC insulated unsheathed single core multi strand fire retardant flexible copper cable for 3 phase EB service connection
144.2.1) Supplying and fixing of 250 Watts Metal halide Flood light etc.,
151.3.1) Supply and laying of the following size of PVC LTUG aluminium armoured cable (below GL) a) 3.5 C x 35 sq.mm. PVC LTUG aluminium armoured cable
162.2.1) Supplying and clamping of PVC armoured LTUG cable(Above GL) a) 3.5 C x 35 sq.mm. PVC LTUG aluminium armoured cable
175.3.1) Supply and fixing of horizontal type 4way triple pole neutral MCB distribution board in sheet steel enclosure double door
207.4.1) Providing two coats of Exterior Emulsion paint including primer for outer walls
238) Anticorrosive treatment for steel grills
238.1) Anticorrosive treatment for window grills
255.2) Supplying and fixing of LED Bulb for suitable for fixing it to pendent / bakelite battern holder a) 9watts LED bulb
b) 12 watts LED bulb
255.6) Supply and fixing of Bulk Head fitting suitable for 12W LED Bulb
344.2) Supply and fixing of Bevelled edge mirror 500 x 400 x 5.5mm
359.3.1) Concrete designer tiles flooring
361.5) Vitrified Tiles (Ivory) 600 x 600 x 8mm Flooring in C.M 1:3
379.4.4) Providing Jet Black Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick for kitchen platform slabs including super fine polish, finishing and fixing in position and pointing with CM 1:3 b. In First floor
383.2) Providing double nosing to the edges of Granite slab
448.2) Providing PVC Tee with end cap
451.3.2) Supplying and fixing of best approved quality of following CP water supply/Sanitary fittings a) CP Angle cock tap
832.5.2)Supplying and fixing in position of UPVC window of casement type( open) for all sizes
832.5.3)Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
M.M. ENGINEERS (BID ID -1170344)
BHARATH BUILDING CONSTRUCTION (BID ID -1169999)
Bidder Name
BHARATH BUILDING CONSTRUCTION
M.M. ENGINEERS
Udayam Engineers and Builders Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_586638.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .