| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC MADHUPUR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.0 L+₹9,354 (0.30%)Rejected-Finance C O AMBU HOTEL NEAR GOVT POLYTECHNIC DOLLY GUNJ PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹31.5 L+₹58,232.40 (1.89%)Rejected-Finance | L3 | Rejected-Finance Rejected due to L3 |
| Sl No | Description | Qty | Unit | OPS Associates L3 | Binod Hawlader L1 | City Constructie Pvt Ltd L2 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc.30cm deep and avg 15 cm getting out in any type of soil complete all as specified and directed. | 45 | Sqm | 60 ₹2,700 | 50 ₹2,250 Lowest | 50 ₹2,250 Lowest |
| 2.00 | Excavating over areas, n exc 1.5 m deep and getting out in foundation etc. and getting out in any type of soil complete all as specified and directed. | 14.2 | Cum | 322 ₹4,572.4 | 300 ₹4,260 | 150 ₹2,130 Lowest |
| 3.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq. m on plan and n exc 1.5 m in depth including forming bottom surface and getting out in any type of soil complete all as specified and directed. | 156.6 | Cum | 282 ₹44,161.2 | 300 ₹46,980 | 150 ₹23,490 Lowest |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming complete all as specified and directed. | 108.7 | Cum | 62 ₹6,739.4 Lowest | 120 ₹13,044 | 100 ₹10,870 |
| 5.00 | Removing excavated material nexc 50 mtrs and deposition where directed at level n exc 1.5 above the starting point complete all as specified and directed. | 62.1 | Cum | 55 ₹3,415.5 Lowest | 120 ₹7,452 | 150 ₹9,315 |
| 6.00 | M&L for hard core of broken stone or boulders of gauge n.exc.63mm, deposited, spread, levelled in layers n.exc.15cm thick, watered and rammed to a true surface complete all as specified and directed. | 9.8 | Cum | 2,625 ₹25,725 | 2,700 ₹26,460 | 2,500 ₹24,500 Lowest |
| 7.00 | M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in fdn etc complete all as specified and directed. | 6.5 | Cum | 8,950 ₹58,175 Lowest | 10,500 ₹68,250 | 10,000 ₹65,000 |
| 8.00 | Pre-cast cement concrete in foundation, filling and mass concrete type using 40mm aggregate grade type 1:2:4, Type C2 for foundation of staging for water storage tank (2mx2mx0.3m) all as specified and as directed by Engr-in-Charge | 4.8 | Cum | 12,800 ₹61,440 | 10,500 ₹50,400 Lowest | 11,000 ₹52,800 |
| 9.00 | M&L for PCC (1:2:4), type B0(using 12.5 mm graded stone aggregate) as in kerb complete all as specified and directed | 1.5 | Cum | 12,800 ₹19,200 | 11,000 ₹16,500 Lowest | 12,000 ₹18,000 |
| 10.00 | M & L for PCC (1:3:6) type B1 as in copping surface channels, benching etc of manholes finished fair and even complete all as specified and directed | 0.7 | Cum | 10,500 ₹7,350 | 10,500 ₹7,350 | 10,000 ₹7,000 Lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
8 Nov 2025, 6:00 pmClosed
GE (South) Diglipur
GE (South) Diglipur RK Gram Diglipur North Andaman 744202
PROVN OF EXHAUST FANS FOR TOILETS AND WALL MOUNTED FANS FOR LIVING IN ACCOMMODATION AND EXTERNAL SERVICES PRE FABRICATED SHELTER AT LAXMIPUR UNDER GE(S) DIGLIPUR
2025_MES_735922_1
8160/E8
Open Tender
Civil Works
Item Rate
270 days
Diglipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (South)
₹64,000
Yes
23 Dec 2025
17 Oct 2025
10 Nov 2025
17 Oct 2025
8 Nov 2025
1 Nov 2025
18 Oct 2025 - 25 Oct 2025
Amount
Surface excavation n.exc.30cm deep and avg 15 cm getting out in any type of soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in foundation etc. and getting out in any type of soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq. m on plan and n exc 1.5 m in depth including forming bottom surface and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming complete all as specified and directed.
Removing excavated material nexc 50 mtrs and deposition where directed at level n exc 1.5 above the starting point complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n.exc.63mm, deposited, spread, levelled in layers n.exc.15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in fdn etc complete all as specified and directed.
Pre-cast cement concrete in foundation, filling and mass concrete type using 40mm aggregate grade type 1:2:4, Type C2 for foundation of staging for water storage tank (2mx2mx0.3m) all as specified and as directed by Engr-in-Charge
M&L for PCC (1:2:4), type B0(using 12.5 mm graded stone aggregate) as in kerb complete all as specified and directed
M & L for PCC (1:3:6) type B1 as in copping surface channels, benching etc of manholes finished fair and even complete all as specified and directed
M&L for Providing Precast Cement Concrete Solid Block Masonry with Solid Blocks exceeding 100mm width with minimum compressive strength of 50kg/sqcm using PCC 1:3:6, type C-1 using 20mm graded stone aggregate set in cement mortar 1:6 complete all as specified and as directed.
Pre-cast cement concrete in foundation, filling and mass concrete type using 20mm aggregate grade type 1:3;6, Type C1 for foundation of staging for water storage tank (2mx2mx0.7m) all as specified and as directed by Engr-in-Charge
M&L for landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces using RCC 1:2:4 type B1 (using 20mm Graded stone aggregate) and set in CM 1:6 including formwork complete all as specified and directed.
Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement incl forms, moulds, stopped complete all as specified and directed.
Supply only water proofing compound.(ISI Marked)
M&L for framed brackets of angle or tees with web and flanges cut to shape drilled and counter-sunk for screw including bending and welding angles as necessary gusset plate, reveting,etc n, exc 10 kg each brackets conforming to fe 290 Gde - E-165 complete all as specified and directed.
S&F Reinforcement using High Strength Corrosion Resistant Deformed TMT bars of Grade Fe-500D of 10 mm dia and over, cut to length , bent to shape required including cranking , bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for staging for water storage tank made up of rolled mild steel in joints channel, angle iron or tee section, fixed independently without connection plates etc ISMC 200x 75=16.80 Kg/m (No 8 and ht 4mtr) A1 quality all as specified and directed by Engr-in-Charge
M & L for framed work as in plates (plain or chequered) channels, square cut or notched with fabrication and refection of FE410-W (Gde E-250) quality A plates 12mm thick all as specified and as directed by Engr-in-Charge
M&L for 100MM thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in PCC Road complete all as specified and directed.
M&L for 75MM thick PCC 1:4:8, type C2 (using 40mm graded stone aggregate) as in sub floor complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25 mm thick sand cushion under flooring complete all as specified and directed.
M&L RCC coventional septic tank designed to carry sewage & sullage water for 50 users, excavation in any type of soil, PCC 1:4:8 below foundation, 1:3:6 PCC solid block masonry in walls, base slab, baffle walls & roof slab including beams etc with vent shaft, mainhole opening with cover connection etc complete complete all as shown in drawing No CE/TD/2022/16 dt 17 Jan 2022.
M&L soakage pit well size of 2.25mtr dia X 1.8 mtr effective depth, excavation in any type of soil, foundation in PCC (1:3:6), walls of honeycombed masonry with top ring of M-25 concrete including intersepting chamber & screen chamber made of brick masonry in CM (1:6), RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed.
M&L for 150mm dia CI pipe Class A with spigot and socket ends centrifugally cast in any length with (or) without ear laid in trenches and jointed in CM 1:1 complete all as specified and directed.
S & F GI Pipe light grade with necessary fittings in trenches/floor/pillar/fixed on pole etc for cable protection of 50 mm dia bore.
Supply, fixing, Jointing and testing 25 mm bore galvanised mild steel water tubing 'medium grade' with and including all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
Supply, fixing, Jointing and testing 40 mm bore galvanised mild steel water tubing 'medium grade' with and including all fittings laid in trenches complete all as specified and directed.
Cutting of existing GI pipes of size 40 to 50 mm dia, inserting of T of suitable size complete all as specified and directed.
S&F 50mm dia low density polythene pipe(LDPE) of pressure rating 6 Kg/Cm2 in weep holes complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks minmum 3 layers, 2000 ltrs capacity (cylindrical vertical with closed top) white in colour hoisted and fixed in position including 25 mm dia Ball brass valves with all fittings and fixtures all as specified and directed.
S & F GI Stop valves of size 25mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for GI pipe complete all as specified and directed.
S & F GI Stop valves of size 40mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for GI pipe complete all as specified and directed.
M&L for PCC (1:3:6) type C2 as to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in for CI pipe 150mm bore complete all as specified and directed.
Supply & Laying, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed.
Supply & Laying, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed.
Point wiring One fan point controlled by one switch using approved colour coding as per IS, with stranded copper conductor 1.5 sqmm (nominal area), single core, flame retardant low smoke(FRLS), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including PVC casing and caping/PVC conduit and its fittings ISI marked, with PVC flush boxes suitable for modular/normal switch/sockets etc with earth dolly incl covered with suitable module cover plate with frame including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 sqmm (nominal are) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified
Ditto as per item no above but One socket out let 5 pin 5 Amp on independent board
Supply and fix modular switch 1 way 6A, 1 module. Make- Legrand/ Crab tree / Philips.
S & F Modular socket outlet 1 way 6 Amps 2/3 pins combined, 2 module Make - Legrand/ Crab tree / Philips
S & F White cover plate with frame, 3 module including metal flush box 3 module
S & F for MCB DB's 8 Way SPN, 240 volts for mounting MCBs/RCBO's ELCB's etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB's shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection. complete all as specified and directed.
S & F for ceiling rose 3 phase/PVC/polycarbonated isolated body complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate elecrode of size 600×600cm× 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to GI earth lead wire of size 4.00mm dia by means of bolts, nuts, check nuts and washers of washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing copper sulphate and salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed
Sub main wiring with approved colour coding as per IS with 2 runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4 Sq. mm and drawing into PVC conduit/ casing and capping including 1 run of PVC insulated 4 sqmm stranded copper conductor earth wire complete all as directed.
M&L for finishing concrete roads, pavements by belting complete all as specified and directed
M&L for finishing concrete roads, pavements by brooming complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed. Note : Cost of Cutting of existing wall / fibre sheet will be included in the quoted price.
M&L for 150MM thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in PCC Road complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering to brick/ concrete surfaces,15mm thick in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F for MCB SP 6-32 Amps 240 Volts C Curve 10 KA
S & F MCB SPN/DP of size 32A, 240Volts 10 KA C curve
S & F for MCB SPN 40 Amps 240 Volts C Curve 10 KA
Forming contraction joint ( dummy ) 40 mm deep x 10 mm wide and used to edges primed with primer suitable for sealing compound grade ' B' complete all as specified and directed
M&L for Plain cement concrete type B 1, 1:2:4 (using 20mm graded granite stone aggregate ) as in banching of manholes including forming centre channels half round or 1/4 section complete all as specified and directed.
S & F DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II , of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler,'O' Ring etc, for protection of cable complete all as specified and directed.
S & F for wall mounting fan 400 mm sweep, 5 star rated BLDC complete with motor over heat protection, powerful motor for higher air delivery, jerk free and uniform oscillation, light weight complete all as specified and directed Make : Havells Model : Platina BLDC or equivalent in Usha/Anchor/ Crompton. (Note : Cost for necessary arrangement for hanging of ceiling fan in op wks shelter will be included in the price)
M & L for boring holes under road, pavement hard standing by trenches technology using ultra sound technique and necessary machinery and tools all as specified and as directed by Engr-in-Charge
S & F medium grade GI pipe bracket 40mm bore of length not less than, 1.20M, bent to shape and fixed to poles/wall with two No MS flat clamps etc duly painted with two coats of alumium paint over a coat of zinc chorme primer complete all as specified and directed.
City Constructie Pvt Ltd (BID ID -3469258)
OPS Associates (BID ID -3470277)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.67 MB
td.pdf
Tender Documents • 0.68 MB
BOQ_824054.xls
BOQ • 0.35 MB
Tender8160.pdf
Tender Documents • 0.66 MB
Tender8060r.pdf
PDF • 1.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .