Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.5 L+₹4.1 L (16.0%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.7 L+₹4.3 L (16.8%)Rejected-AOC 37 4TH CROSS ASHWATHNAGAR SANJYANAGAR POST BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹31.7 L+₹6.2 L (24.5%)Rejected-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended due to not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹58,360
Closing Date
4 Sept 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR / MAINT OF EXTERNAL WATER SUPPLY DISTRIBUTION LINES AND RISING MAINS AND CLEANING OF OHT / UG SUMPS AND HOUSE SERVICE TANKS AND REPAIR AND MAINTENANCE TO TREATED WATER TO STP AT HQTC BANGALORE
2024_MES_663283_1
8233/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹58,360
21 Oct 2024
1 Jul 2024
11 Sept 2024
1 Jul 2024
4 Sept 2024
15 Jul 2024
2 Jul 2024 - 9 Jul 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes,complete all as specified and directed.
Returning, filling of excavated soil in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil at a distance not exc.50m and depositing at a level n exc 1.5 m all as specified and directed by Engineer-in-Charge.
Taking up or down GI pipes medium grade alongwith pipe fittings from trenches floors, walls and roof etc including cleaning for refixingor removal to store the following sizes :-
100mm dia
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply and fix in repair galvanised water tubes, medium grade including all fittings, laid in wall/ ceiling/floors complete of following sizes all as specified and as directed.
40mm dia
25mm dia
20mm dia
15mm dia
Supply and fix in repair galvanised water tubes, light grade including all fittings, laid in trenches complete of following sizes all as specified and as directed.
100mm dia
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply & fixing in repair Gun-metal, globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of following sizes including all fittings nuts, bolt&Washers etc complete all as specified & directed by Engr-in-Charge. MAKES –NETA/SIGMA/LEADER
100 mm dia
80 mm dia
50 mm dia
40 mm dia
25 mm dia.
20 mm dia.
15 mm dia
Relaying only GI tubing of medium grade obtained from item No. 4 above, in trenches/walls/ ceiling including provision of new fittings complete in old/new location of following sizes all as specified and as directed. Note : Excavation and earth work where required shall be measured and paid separately under relevant items of this Schedule
100mm dia
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Taking up cast iron water pipe (including all fittings), with spigot and socket ends and lead joints ncluding burning out joints and recovering lead complete all as specified and directed.
200 mm dia
150 mm dia.
100 mm dia.
Supply and fix CI fittings, heavy duty, such as bends, tapers, tees,collars,tail pieces, reducers, etc laid and jointed with suitable push on joints complete upto 150 mm dia all as specified and as directed.
Supply and fix CI fittings, heavy duty, such as bends, tapers, tees,collars,tail pieces, reducers, etc laid and jointed with suitable push on joints complete upto 200 to 300 mm dia complete all as specified and as directed.
Supply, laying and testing of Ductile iron pipes, 200mm dia, class K-9, with spigot and socketed ends centrifugally cast (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint (rubber gasket D joint), complete all as specified and as directed. Make:Sreepipe Note: Excavation and earth work and DI specials where wherever required shall be measured and paid separately under relevant item of this schedule.
All as per item No 12 above but 150 mm dia
All as per item No. 12 above but 100 mm dia
M&L cement concrete type D- 2, 1:4:8 using 40mm grade aggregate complete all as specified and directed.
Supply and fix CI sluice valve of pressure Class PN - 1.6 flanged, 200 mm dia and drilled at both ends with ISI mark, having steel spindle and gunmetal rings including wheel for operation all as specifed and all jointing materials, bolts, nuts, washers, and necessary civil works such as Demoltion,Excavation, Removing and returning filling etc, all as specifed and as directed including dismantling and taking up unserviceable valve all as specified and as directed.
All as per item No.16 above but 150 mm bore
All as per item No.16 above but 100 mm bore
All as per item No.16 above but 80 mm bore
Supply and fix Run lead joints for CI spigot and socket pipes 200 mm dia all as specified and as directed.
All as per item No 20 above but 150 mm dia
All as per item No 20 above but 100 mm dia
All as per item No 20 above but 80mm dia
M&L for Stainless steel spindle and lock nut suitable for 200 mm size sluice valves, duly threaded fitted with necessary fabrication work to suit with existing size including provision of new gland packing and new strands and nuts, bolts,washer, fittings,as per site requirement including taking out unserviceable spindle from the existing sluice valve and necessary civil works such as Demoltion, Excavation, Removing and returning filling and including all necessary fittings complete all as specified and as directed.
All as per item No 24 above but 150 mm bore all as specified and dirrected.
All as per item No 24 above but 100 mm bore all as specified and directed.
All as per item No 24 above but 80 mm bore all as specified and directed.
Supply and fix Non return valve, heavy duty, ISI Marked, PN –1.0, both end flanged, suitable to fix with 150mm dia pipe line including nuts, bolts,washer, fittings,as per site requirement including taking down existing unserviceable non return valve all as specified and as directed.
Supply and fix Non return valve, heavy duty, ISI Marked, PN –1.0, both end flanged, suitable to fix with 80mm dia pipe line including nuts, bolts,washer, fittings,as per site requirement including taking down existing unserviceable non return valve all as specified and as directed.
Material and labour for attending break down maintenance of pumping line CI/DI/MS upto 300 mm dia from CJF pump house at Malleshwaram to HQTC pump house including necessary earth work to a depth not exceeding 2.0 meter wherever as required using JCB/ Manual according to the site condition and making good the distrubed surfaces / road cuttings by refilling and removing surplus soil to a distance complete all as specified and directed by Eng-in-Charge. (a) The contractor shall supply any kind of tools & machinery required for the completion of job. (b) Execution of work / attending break down may also occur in the civil area / road crossing. Therefore the quoted rate is deemed to be inclusive of any precautionery measures while working on public places and strict adherence to the norms as applicable (c) Any kind of CI/DI/MS Pipe line upto 300 mm dia bore, fittings like collar or bends etc and run lead joint shall not be measured and paid separately.
Supply and fix air release valve 150mm dia including all joint with rubber gasket and jonting materials , bolts , nuts, washers ,fittings,as per site requirement including dismantling and removing unserviceable valve complete all as specified and as directed.
Supply and fix Butterfly valve, heavy duty, ISI Marked, both end flanged, suitable to fix with 150mm dia pipe line all as specified and as directed.
All as per item No 32 above but 100 mm dia
All as per item No 32 above but 80 mm dia
All as per item No 32 above but 65 mm dia
All as per item No 32 above but 50 mm dia
S&F ball valve high pressure PTMT with epoxy coated aluminium rod and high denacity plastic ball screwed for iron pipe of 15 mm dia min weight 142 grams all as specified and as directed.
All as per item No 37 above but 20 mm dia
All as per item No 37 above but 25 mm dia
Suppy and laying of CPVC pipe SDR 11 of size 15mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Suppy and laying of CPVC pipe SDR 11 of size 20mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Supply and laying of CPVC pipe SDR 11 of size 25mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Supply and laying of CPVC pipe SDR 11 of size 32mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Supply and laying of CPVC pipe SDR 11 of size 40mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Supply and laying of CPVC pipe SDR 11 of size 50mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
Supply and laying of CPVC pipe SDR 40 and Plain Schedule 80 fittings of size 80mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
S&F CPVC ball valve of size 80 mm dia complete all as specified and as directed
S&F CPVC ball valve of size 50 mm dia complete all as specified and as directed
S&F CPVC ball valve of size 40 mm dia complete all as specified and as directed
S&F CPVC ball valve of size 25 mm dia complete all as specified and as directed
S&F CPVC ball valve of size 20 mm dia complete all as specified and as directed
S&F CPVC ball valve of size 15 mm dia complete all as specified and as directed
S&F in repair bib tap standard PTMT of any colour high pressure screwed for iron pipe of size 15mm dia minimum weight 90 grams complete all as specified and as directed.
S&F in repair bib tap strandard of PTMT any colour high pressure screwed for iron pipe of size 20mm dia minimum weight 90 grams complete all as specified and as directed..
M&L cement concrete type B- 1, 1:2:4 using 20mm grade aggregate in mass concrete complete all as specified and directed.
Taking down CPVC pipe SDR 11, 15mm outer dia with all fittings.
Taking down CPVC pipe SDR 11, 20mm outer dia with all fittings.
Taking down CPVC pipe SDR 11, 25mm outer dia with all fittings.
Taking down CPVC pipe SDR 11, 32mm outer dia with all fittings.
Taking down CPVC pipe SDR 11, 40mm outer dia with all fittings.
Taking down CPVC pipe SDR 11, 50 mm outer dia with all fittings.
Taking down CPVC pipe SDR 80, 80 mm outer dia with all fittings.
S&F water meter with flanged 200mm dia DI/CI/MS/GI pipe with necessary cutting, fitting such flages, nuts bolts washers, unions, tees elbow and etc and including all fixtures and excavation as required, testing and commissioning, complete all as specfied and directed.
All as per item No 63 above but 150 mm dia
All as per item No 63 above but 100 mm dia
All as per item No 63 above but 80 mm dia
De-watering, removing all moses, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead reservoir/ under ground sump by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing of the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound by approved chemical and bleaching powder and writing the date of cleaning on outside of tank/ sump using synthetic enamel paint of white colour over black background with letters of size 100mm height x 100mm wide complete for OH Reservoir 1,00,000 Gallons capacity with 98 feet staging complete al las specified and as directed.
All as per item No.67 above but OH Reservoir 50,000 Gallons capacity with 65 feet staging
All as per item No.67 above but UG sump 25000 ltrs capacity
All as per item No.67 above but OH Reservoir 10,000 Gallons capacity with 60 feet staging
All as per item No.67 above but including white wash outer side of UG sump 1,50,000 Gallons capacity
All as per item No.67 above but including white wash outer side of UG sump 75,000 Gallons capacity
All as per item No.67 above but including white was outer side of UG sump 50,000 Gallon capacity
All as per item No.67 above but collection tank swimming pool 50,000 Litres capacity
All as per item No.67 above but under Ground Sump 10,000 ltrs capacity
All as per item No.67 above but Static water tank 50,000 litres capacity
All as per item No. 67 above but OH service tank upto 25000 ltrs capacity
All as per item No. 67 above but PVC under ground tank upto 5000 ltrs capacity
Supply and fix in repair flexible PVC braided pipe, heavy duty, 50mm dia with circlips/ clamps suitable for suction sweeper all as specified and as directed.
Supply and fix in repair flexible PVC braided pipe, heavy duty, 40mm dia with circlips/ clamps suitable for suction sweeper all as specified and as directed.
Supply and fix in repair flexible PVC braided pipe, heavy duty, 25mm dia with circlips/ clamps suitable for suction sweeper all as specified and as directed.
Supply and fix Nylon rope heavy duty (Manila type) of size 25mm dia all as specified and as directed.
Supply and fix, in reparir, Nylon brush suitable for suction sweeper, 2 feet x 2 inch size with necessary nuts, bolts, washers etc including removing unserviceable brush all as specified and as directed.
Supply anf fix in repair rubber gasket suitable for suction sweeper including MS flat strip support, bolts, nuts and washers complete, fixed in repairs all as specified and as directed.
Supply & fixing in repair Gun-metal, globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of size 15 mm including taking down complete all as specified & directed by Engr-in-Charge. MAKES –NETA/SIGMA/LEADER
All as per item No 85 above but 20 mm dia.
All as per item No 85 above but 25 mm dia.
All as per item No 85 above but 40 mm dia
Supply and fixing galvnised water tubes, light grade,50 mm bore including all new fittings, laid in wall/ ceiling and floor complete of following sizes all as specified and as directed. Make Jindal/Tata/Zenith
All as per item No 89 above but medium grade GI pipe 25 mm bore.
Dewatering, cleaning of FIDAS/UG sump at STP with high pressure water jet to remove all mosses, algae and dirt and removal of dirty water using sludge pump set/industrial vaccume cleaners and disposing of the same to a safe distance and including scrubbing of internal floor surface by using steel brush, removing of dirt,spread the bleaching powder around the tank completely and carefully remove the diffuser and after cleaning re-connection of the diffusers ,testing the same including applying two coats of white wash to external surface complete and writing in white colour the date of cleaning by using synthetic enamel paint over black back ground with letters of size 100mm height, 100mm wide complete all as specified and directed for FIDAS 50000 Ltrs capacity.
All as per item No.91 above but UG Raw water sump of capacity 100000 ltrs including incoming chambers.
All as per item No.92 above but UG sump 25000 ltrs (clarified water collection tank) capacity
All as per item No.93 above but treated water UG Sump 100000 Ltrs capacity
Supply and fix butterfly valve of size 100mm dia complete fittings SI marked, with bolts and nuts and washers including providing rubber insertion of suitable thickness complete ncluding taking out existing unserviceable valve as per existing make. all as specified and directed by Engineer in charge.
Supply and fix butterfly valve of size 150mm dia complete fittings SI marked, with bolts and nuts and washers including providing rubber insertion of suitable thickness complete including taking out existing unserviceable valves as per existing make all as specified and directed by Engineer in charge.
Supply & fix PVC control valve 25mm dia of superior quality all as all as specified and directed by Engineer in charge.
Supply & fix PVC control valve 20mm dia of superior quality all as specified and as directed.
Comprehensive repairs and servicing of chloronome plants of sodium hypo-chlorite dosing plant of chlorine dosing system high pressure single head gear motored adjustable with tank make declibac at HQTC main pump house, swimming pool and STP -04 Nos, cleaning of chlorine tank and necessary repair & replacement of unserviceable parts & reassembling the same including testing complete all as specified and directed by Engineer in charge. Notes-: Spare parts required in servicing shall be measeured and paid separately.
Supply and fix “Foot Valve assembly” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix “Anti Siphon Valve” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix “Pulsar circuit and speed potential meter” and adjustable motor for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix“Diaphragm” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix “PVC Pipe heavy duty” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix “Suction valve seal” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix “Ball ceramic” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
Supply and fix“Diaphragm Seal” for sodium hypo-chlorite dosing pump complete as per existing make all as specified and directed by Engineer in charge.
M&L for Servicing of LT panel boards at swimming pool installation with switch gears consisting of Incoming and out going MCCBs, pump set starters and connected accessories complete all as specified / comprising the following tasks :- (i) Cleaning with blower (ii) Cleaning with brush (iii) Replacement of damaged cable lugs (iv) Replacement of deteriorated copper wiring (v) Replacement of sheared rubber beadings (vi) Tightening of loose connections (vii) Preparation of old painted surfaces and applying one coat of metallic spray paint of approved colour. (viii) hinges and welding as required
Supply and fix in repair PPR pipe PN 1.6 , 40mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
Supply and fix in repair PPR pipe PN 1.6 , 50 mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
Supply and fix in repair PPR pipe PN 1.6 , 75 mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
Supply and fix in repair PPR Valve dia 40mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
Supply and fix in repair PPR Valve dia 50mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
Supply and fix in repair PPR Valve dia 63 mm dia with all fitting such as elbows, tees, unions, collar etc all as specified and as directed.
M/S Jaiprakash Electrical and Engineering Works (BID ID -3067269)
M/S J S PRAKASAM (BID ID -3070652)
ANAND REFRIGERATION (BID ID -3071027)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .