Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 677A DIAMOND HARBAR ROAD HINDUSTAN PARK BEHALA KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹14.3 L+₹88,268 (6.57%)Rejected-Finance | L2 | Rejected-Finance higher rate quoted | |
| 3 | L3₹15.6 L+₹2.2 L (16.1%)Rejected-Finance ACROPOLIS 12 FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | L3 | Rejected-Finance higher rate quoted | |
| 4 | L4₹19.9 L+₹6.4 L (48.0%)Rejected-Finance GN 34 2 ASHRAM BUILDING SECTOR V SALT LAKE KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L4 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
11 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE II CKHED
P12 CIT Road 1st floor Kol 14
Replacement and Restoration of damaged Solar System by Super Cyclone AMPHAN at the Roof Top of Academic Building within the compound of NRS Medical College and Hospital Kolkata
2022_WBPWD_372588_1
WBPWD/EE-II/CKHED/NIT-23/21-22 2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
NRS MCH
as per NIT
5 documents required · 5 mandatory
₹30,000
P12 CIT Road 1st floor Kol 14
28 Apr 2022
22 Mar 2022
13 Apr 2022
22 Mar 2022
11 Apr 2022
31 Mar 2022
29 Mar 2022
120 days
Amount
Dismantling of existing Module mounting structure and removal of all debris, as directed by EIC.
SITC of Module Structure for solar system, Module Mounting stainless steel screws etc. with following specs .: All structures will be with Hot dip galvanized steel with a min. galvanization thickness of 90 microns of aluminum alloy mounting structure shall be corrosion resistant and electrically compatible with the materials used in the module frame, its fasteners and nuts and bolts. The fasteners used should be compatible with the structure materials. The mounting structure shall be as per IS : 2062:1992. & galvanization as per IS : 4759 & ASTM A 123 incl. low profile robust & withstand high wind load as per IS standard of the area. Min. distance between roof edge & mounting structure should be 0.3m,
Supplying, fitting & fixing Solar panel base size of 300 x 300mm x 300mm with M25 grade concrete work including necessary reinforcement, shuttering, 2nos HILTI make TATA approved Hy-200R chemical for embedment of 200m With 16mm dia rebus etc., .& 4 Nos holding down bolts of 16 mm dia including is necessary arrangements and as per direction of EIC. , as directed by EIC.
SITC of 315Wp poly crystalline solar PV Module having matching of existing module following specs. :PV module should be made up of solar mono crystalline module and must have a certificate to IEC 61215 or IEEE 1262 or CEC 503 for crystalline silicon and IEC 61730 Part I & II for safety qualification testing. The power output of the modules under STC should be a minimum of 300Wp and above wattage. The module shall perform satisfactorily in humidity up to 100% with temperature between 0°C to 60°C . SPV conversion efficiency should be greater than 18% under STC and AM 1.5 radiation. The module should be robust non corroding Aluminum frame. The rated power of the module shall have tolerance of +2.5% , as directed by EIC. [Make for SPV Module :- Vikram Solar/ Waaree/ TATA Solar/websol/ BHEL/ Sova Soler / Emmvee Photovoltics], furnished in Annexure - "A".
Repairing and refixing of existing module mounted structure and solar module and necessary connection, as directed by EIC.
Cost for scaffolding for carrying of module mounted structure, solar module and existing PCC foundation,at roof of (G+9) building as directed by EIC.
SITC of DC double insulated cables, single core 4 Sq.mm. FRLS (Make : RR Cable/Polycab/Finolex/Gloster)
(LESS) Buy-back value of dismantling of hot dip galvanized steel module structure as directed by EIC.
Annexure is attached in separate sheet
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Jupiter International Limited
Lumino Industries Ltd.
Salt Lake Institute of Engineering and Managment
stage.html
html • 0.05 MB
technical_725299.pdf
PDF • 0.12 MB
techsummary_725299.pdf
PDF • 0.14 MB
finance_725299.pdf
PDF • 0.09 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_725299.pdf
PDF • 0.14 MB
WO.pdf
PDF • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .