| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.3 L+₹18,972.80 (2.67%)Rejected-Finance SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹8.3 L+₹1.2 L (17.0%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹8.6 L+₹1.5 L (20.5%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹16.4 L+₹9.3 L (130.9%)Rejected-Finance 27 D POCKET 1 DDA MIG FLATS MAYUR VIHAR PHASE 3 DELHI 110096 | EAST | DELHI | 110096 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
2 Jun 2022, 6:00 pmClosed
Niteen M Waghmare
AGE(I)(U) B/R, Delhi Cantt-10
Repair/ Replacement of Internal wiring including fitting / fixtures in E/M Installation under AGE (I) (U) B/R Delhi Cantt-10.
2022_MES_523713_1
8611/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I)(U) B/R, Delhi Cantt-10
As per NIT
7 documents required · 7 mandatory
₹50
AGE(I)(U) B/R, Delhi Cantt-10
₹20,000
1 Jul 2022
12 May 2022
4 Jun 2022
12 May 2022
2 Jun 2022
25 May 2022
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall on wall including sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed for One light /fan/ bell point controlled by one, one way switch 05 Amps.
All as per above item No. 02 but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch all as specified and directed.
All as per above item No. 02 but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch all as specified and directed.
All as per above item No. 02 bu point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F switch piano flush type, 16 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts with socket frame complete.
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 250 volts with socket frame complete all as specified & directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and directed.
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals complete all as specified and directed.
S&F surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in repair switch piano flush type, 05 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F in repair switch piano flush type, 15 Amps, single pole, one way, 250 volts complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin, 05 Amps, flush type, 250 volts with socket frame complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 5 pin, 05 Amps, flush type, 250 volts complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 05 Amps and 3 pin, 15 Amps, flush type, 250 volts with socket frame complete all as specified & directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 05 and 15 Amps, flush type, 250 volts with complete all as specified & directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and directed.
S&F in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
S&F in repair tube light fitting and S&F on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
Supply and fix High efficiency round highbay in PDC housing suitable for industrial luminair efficincy upto 110 Lm/W reduce quality capacity 90 Watt complete all as specified and directed / Make : CG cat No LBH11-90-CDL/60-M or equivalent.
S&F LED street light 35 watt 230 Volt AC outdoor type with high pressure die cast aluminium hosing and heatresistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete.
All as as above but for 02 x 4 Sqmm for phase & neutral and 01 x 4 Sqmm for continuous earth wire.
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete.
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete.
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 25 KA suitable for load line/ VTPN DB & connection complete all as specified and directed.
S&F MCB, SP, AC, 240 volts of 10 to 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F MCB, SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in repair MCB, SP, AC, 240 volts of 10 to 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in repair MCB, SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in repair MCB, TPN/FP 415 V, 40 t0 100 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed by Engr-in-charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceedidng 1.5 mtr depth for laying of LT UG cable and getting out complete all as specified and directed.
Returning, filling in, trenches with soft/ loose soil including spreading levelling watering and well ramming in layers not exc 25 cm with excavated soil complete all as directed.
Removing surplus spoil to a distance not exc 50 mtr away and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engineer-in-Charge.
M&L tubing GI light grade laying for protection of LT under ground cable of size 40mm bore complete all as specified and directed.
Supply and laying (in replacement) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core incl tacking out complete all as specified and directed.
Taking down ceiling fan any make from ceiling carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original / desired location with necessary connection incl provision of cable from ceiling rose to connector of fan after repairing, greasing, oiling, replacement of minor items such as pins, nut bolts, flexible wire etc incl spray painting with synthetic enamel paint in white colour complete .
Haryana EngineerService
SAGAR ENTERPRISES
S D Constructions
Usha Contractors and Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .