Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-MSE/ Tender fee & EMD not submitted physically as per tender document |
Tender Value
₹15.1 L
EMD Value
₹30,224
Closing Date
17 Feb 2024, 3:00 pmClosed
SM ( E ) Z4
1st floor, TE Bldg Goregaon, SV road, Goregaon West, Mumbai-400104
As per NIT
2024_MTNL_794328_1
SM (E) Z4/NIT/23-24/37
Open Tender
Electrical Works
Item Rate
30 days
TE Bldg Goregaon
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer (CASH-BW), MTNL
₹30,224
Yes
2 Mar 2024
7 Feb 2024
19 Feb 2024
7 Feb 2024
17 Feb 2024
7 Feb 2024
Repairing and Servicing of Diesel engine driven Pump of capacity 72 HP pump i.e cleaning, oiling, greasing cleaning Filter and changing of Gasket Brushing, changing of coolant of engine oil and filters, wiping, and testing etc complete as required as per site condition.
Repairing and Servicing of Main Fire Hydrant Pump of capacity 60 HP pump i.e cleaning, oiling, greasing changing of Gasket, Brushing, wiping and testing etc complete as required as per site condition.
Repairing and Servicing of Jockey Pump of capacity 15HP pump i.e cleaning, oiling, greasing, Brushing, wiping, and testing etc complete as required as per site condition.
Repairing and Servicing of Booster Pump 5 HP i.e cleaning, oiling, greasing, Brushing, wiping, and testing etc complete as required as per site condition.
SITC of backup battery for Diesel Engine driven Pump 12V x 150 AH.
Supplying, installing pressure gauge of 100mm dia,0-21 kg/cm2, fitted with 12/15 mm dia pad cock valve etc. complete as required including removing existing faulty pressure switches and handing over to building in charge.
Repairing ,cleaning, oiling and servicing of hydrant valves to courtyard stand posts including all nuts bolts gaskets etc. complete.
Servicing ,cleaning and oiling of 4 nos. 65 dia breaching inlet connection near the building compound wall for connecting to fire fighting tank.
Servicing ,cleaning and oiling of 4 nos. 65 dia breaching Siamese connection near the building compound wall for connecting to fire fighting tank.
Repairing, cleaning, oiling and servicing of hydrant valves to the wet riser flanged tee at each floor
Replacement of hydrant valve parts i.e coupling/ lugs / washer
Repairing and servicing of Hose Reel Drum
Supplying and installing cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. Of 150 mm dia
Supplying and installing cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. Of 100 mm dia
Supplying and installing cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. Of 80 mm dia
Providing and fixing in position 2 lengths of 15 M long controlled percolation hose RRL fire hose 63 dia (as per IS 636)with adapter and nozzle and stroking them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted
Supplying and erecting M.S./CRCA cabinet (size 400 x 800 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour
Providing of Diesel oil for Diesel pump (i/c cleaning the diesel tank & painting)
Under ground: SITC of 150mm 'C' class ERW G.I pipes with necessary fittings like Elbow, Tee, Reducer, Flange, Nipple, bend etc as per IS:1239-1973 with one coat of hessian and two coats of anti corrosive primer ( Black Japan) & 4mm thick Wrapping as per IS 10221to be laid at a depth of 1 mtr. Below ground from pump house to ring main, ring main of wet risers etc. complete as required.
Excavation & filling of trencher for underground piping in RCC/PCC/ Hard / Road/hard morrow etc, complete as require.
Excavation & filling of trencher for underground piping removing extra earth morrow complete as require (soft soil/ earth)
Replacement of 25 mm dia air release valve
Supplying, installing and testing of 150mm dia C.I.Foot valve with strainer with nuts, bolts, gaskets, washers etc for positive suction etc. complete as required
Supplying, installing and testing of 80mm dia C.I.Foot valve with strainer with nuts, bolts, gaskets, washers etc for positive suction etc. complete as required
Repairing of Fire Alarm System. With Main Control Panel, with repairing of 26 Zone Cards, power supply module, faulty relay and IC etc.
Repairing of Local Control Panel, with repairing of Various Zone Cards, power supply module, faulty relay and IC etc.
Replacement of 12 Volt 32AH Backup Batteries
Supplying, Installing, Testing & Commissioning of suitable Amplifier for PA system
Replacement of of Multi criteria Photoelectric Type Smoke Detectors i/c base complete as per specifications.
Replacement of Manual Call Points complete as per specifications.
Replacement of Hooters complete as per specifications.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .