| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC All documents submitted and found O.K. Comparative lower rate | |
| 2 | L2₹1.9 L+₹2,996 (1.63%)Rejected-Finance AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | L2 | Rejected-Finance Comparative higher rate. | |
| 3 | L3₹1.9 L+₹6,471 (3.53%)Rejected-Finance AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | L3 | Rejected-Finance Comparative higher rate. |
Tender Value
₹2.2 L
EMD Value
₹2,800
Closing Date
21 Mar 2025, 11:00 amClosed
Amit Kumar, Dy. Manager(CP)
Office of the Project Officer, Sawang Washery
Partial electrical wiring and providing proper power controlling switches for safety of all connected electrical and electronic equipments with lightning arrestor and earth pits and its accessories as and when basis at both rail in motion weighbridge
2025_CCL_332118_1
SGW/KTA/ENM/E-Tender/24-25/104 Date 11.03.2025
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Office of the Project Officer, Sawang Washery
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,800
24 Mar 2025
11 Mar 2025
22 Mar 2025
12 Mar 2025
21 Mar 2025
12 Mar 2025
12 Mar 2025 - 18 Mar 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
(c) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
(d) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/ 415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)way (4 + 12), Double door Each
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required
Supply & installation of three phase surge protector
Supply of RCBO 40 Amps. 30 mA. double pole
Supply of Changeover switch 63 Amps x 415V. 3 pole
Supply of ICTP switch fuse unit 63 Amps. X 415V.3 pole
Cost of lightening arrestor/lightening conductor make of 19 mm copper bar with tripped on top 01 mtr. Length
Chemical earthing with 2.7 mtr. long G.I pipe having outer dia of 50 mm with back filling compound 2 bag including cutting and refilling of soil.
Labour charge 15 % above Sl. No. 8 to 10 (Rs. 22,119.62
Total impact of GST for the purpose of CTC
AASHISH ENTERPRISES (BID ID -1142142)
M S ENTERPRISES (BID ID -1142149)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .