| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.5 L+₹1.3 L (4.84%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹28.1 L+₹1.9 L (7.14%)Rejected-Finance | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹28.4 L+₹2.2 L (8.29%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L4 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
6 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer services AF Stn Adampur 144103
PROVN OF UTILITY SERVICES TO AGNIVEERVAYU (WOMEN) AND CONNECTED WORKS AT AF STN ADAMPUR
2023_MES_618204_1
GE/AF/ADM-35/2023-24
Open Tender
Civil Works
Item Rate
180 days
Under GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹48,000
Yes
11 Nov 2023
11 Sept 2023
7 Oct 2023
11 Sept 2023
6 Oct 2023
23 Sept 2023
12 Sept 2023 - 22 Sept 2023
Amount
BR WORKS
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified.
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soilcomplete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Sand filling under floors including spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Broken bricks hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified.
Anti-termite treatment of soil by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified.
Anti-termite treatment of soil by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
Anti-termite treatment of soil by treating soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded stone aggregates, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded stone aggregates, as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts complete all as specified.
Supply only water proofing compound, ISI marked, complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Brick work in half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
40 mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4, type B-0, using water proofing compound, complete all as specified. NOTE: Water proofing compound will be measured and paid for separately under respective item of BoQ.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded wood grain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and wood grain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window /Ceosetory windows & other Frames/Chowkhat of size 63x51 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/Cu.m, screw withdrawl strength of 2200N Face & 1100 N (Edge), minimum compressive strength of 58 N/ Sq.mm, modules of elasticity 900 N/Sq.mm and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete .
Factory made single extrudeed WPC (Wood Polymer Composite) solid plain flush door shutter of 18mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), clacium carbonate and natural fibres (Wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) having minimum density of 650 kg/Cu.m and screw withdrawl strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50N/Sq.mm, modulus of elasticity 850 N/Sq.mm and resitance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixing complete.
Aluminium anodised barrel tower bolt of extruded section 200 mm long, ISI marked, complete all as specified.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long, complete all as specified.
Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified. MAKE: PRAYAG CAT NO. HG-3414 or equivalent make mentioned in Appndix 'B'
Stainless steel 100mm size auto soft closing hinges fixed with stainless steel screws, ISI marked complete all as specified. MAKE:-Godrej / Prayag / Hettich
Extruded aluminium anodised handles fabricated type with plate 125 mm long, ISI marked complete all as specified.
Magnetic catches brass body and striking plate and fixed in cupboards , ISI marked complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
Steel windows or ventilators, fixed type made of MS sheet 1.25 mm thick box type (primer coated), ERW hollow 'P' section of size 60mm x 25 mm complete all as specified. NOTES: (a) Profile section used under these items shall be 'P' tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable. (b) Cost of one shop coat of zink chromate primer shall be measured and paid for separately under respective item of painting.
Water Proofing Treatment to RCC roofs comprising of : -
Rendering 15 mm thick (Average thickness) rendering on roof surface finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
NOTE : For Guarantee of Water Proofing Treatment refer PS clause 11.5.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified.
Rendering 10 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
Three coats of white washing on new undecorated ceiling surfaces, including preparation of surfaces, complete all as specified.
Two coats of cement base paint on wall surfaces including preparation of new surfaces complete all as specified.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Figured glass 4mm thick ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
1000 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP/outer edge of roof, complete all as specified.
Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6510 or equivalent make mentioned in Appendix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6518 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6508 or equivalent make mentioned in Appendix 'B'.
Center hole basin mixer without pop up, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6550 or equivalent make mentioned in Appendix 'B'.
125 mm size overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, complete. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix 'B'.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), 110x125 size uPVC 'P' trap & necessary joints, lime concrete complete all as specified. MAKE: PRAYAG Cat No. 4055 or equivalent make mentioned in Appendix 'B'
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with1.50 metre long braded tube tube, soft close PVC seat & cover and uPVC 'S trap, complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix 'B'.
Vitreous China wash hand basin, counter type, white, oval shape of size 560 x 410 x 180 mm including fixing acessories like 32mm dia CP waste coupling, CP bottle trap & PVC collapsible waste pipe IN REPLACEMENT, complete. MAKE:PRAYAG Cat No. 4790 or equivalent make mentioned in Appndix 'B'.
Health faust with 1 metre SS tube & hook complete. MAKE: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appendix 'B'.
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, complete. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appendix 'B'
5-6 mm thick looking glass fixed over not less than 6 mm thick PVC ply and approved shade PVC beading not less than 15 mm wide alround with and including all fixing acessories, complete all as specified.
Glass shelf 500x125 mm with brass brackets and fixed to wall with chromium plated brass screws and rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-45 or equivalent make mentioned in Appendix 'B'.
Brass chromium plated towel rail 500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix 'B'.
Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-05 or equivalent make mentioned in Appendix 'B'.
Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints, complete all as specified.
PVC connections with PTMT nuts, 450 mm long, complete all as specified.
Stainless steel peg set of six, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-30 or equivalent make mentioned in Appendix 'B'.
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, complete all as specified.
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, complete all as specified.
uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified.
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), complete all as specified,
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
EM WORKS
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40-63 Amp complete all as specified.
Blanking plate to cover unused space in DB's complete all as specified..
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 15.15.1 of contract, NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser for glarefree light, 6000K, including making connections, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly LED 10 W batten with polycarbonate housing & integrated electronic driver, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. LUMILINEBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly decorative ultra slim round profile LED 22 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified. MAKE: Havells Cat No. FHEHDSPDB120 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Exhaust fan 380 mm sweep with blades, frame and louvers, AC single phase, 230 V, steel body, heavy duty fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified. MAKE: Havells Cat No. FHEHDSPDB150 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Electric water heater storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litre, BEE 5 star rating complete with all accessories such as safety valve, thermostate, NRV, steel PVC connector for hot water etc complete all as specified. MAKE: Havells Cat No. GHWAFATWB025 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
Steel tubes 50 mm bore ‘light grade’, galvanized with all fittings and fixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles complete all as specified of sectional area 16 Sq. mm, 2 core.
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified of sectional area 50 Sq. mm, 3.5 core.
DISMANTLING/DEMOLITION WORKS
Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
M/s Sahib and Company
JAI DURGA CONSTRUCTION COMPANY
M/S GURBACHAN SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .