| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.0 L+₹2.3 L (15.7%)Rejected-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹17.9 L+₹3.2 L (21.7%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Nov 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-58/2020-21 ADDN/ ALTN TO BLDG NO T-109 AT COMMAND HOSPITAL (NC) UNDER GE (NORTH) UDHAMPUR
2020_MES_385458_1
GE/U(N)-58/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹30,000
Yes
14 Nov 2020
12 Oct 2020
7 Nov 2020
12 Oct 2020
5 Nov 2020
24 Oct 2020
Amount
Dismantling of plain or corrugated Asbestos sheets of any thickness or any description in roof coverings complete all as specified and directed by Engineer-in-Charge”
Pre-painted coloured profiled Galvalume/ Zincalume sheet 0.50mm thick TCT of grading YS-550, coating class AZ-150, class-3 confirming to IS-15965-2012, pitch profile c/c n.exc 203mm & crest of profile not less than 28.5mm as in roof covering/cladding to wall fixed with self taping screws/fastners with EPDM seals including gap filling between sheet and wall with PCC (1:3:6) as per site requirement complete all as specified and directed by Engineer-in-Charge”
“------Ditto--------as per Item No. 2 here-in-before but plain ridge profile sheet as in eaves, gutter,ridge etc complete all as specified
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. of any size in section complete all as specified.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including tubular pipes, Chequered plates and plain plastes of any thickness and distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality- Bcomplete all as specified and directed by Engineer-in-Charge”
Preparation of steel surfaces of any description over 10cm width or girth not other wise describe, two coat of synthetic enamel paint and over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge”
Preparation of old or previously painted steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Dismantling ceiling boards,fibre pulb insulation etc or insulation boards/slabs/blankets,any thickness, including cover and MS Tee grid,all as specified.
False ceiling with Everest Fibre Cement Designer tile Ivory/white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 595mmx595mm and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gms, both sides inclusive) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0..30mm thick sheet and cross T of size 15x32mm made of 0.30mm sheet spaced between main T at 600mm c/c from a grid of 600x600mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers grils, light suspended from ceiling using GI soffit cleats fixed to existing rafters, purlin etc with dash fastners GI adjustable rods of 3mm dia wit galvanised butterfly level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centre black pre-painted with polyester painnt and having a load bearingcapacity of 12 kg/sqm and refixed all exesting electric wiring and fixture all complete at all heights as per directed
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing and rubbish off the premises complete all as specified and directed by Engineer-in-Charge”
Coloured glazed ceramic coloured tiles 600 mm x 300 mm x 10mm thick on vertical surfaces of walls as in dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:4 and fair to recive tiles as in skirting/dado etc complete all specified
Non skid ceramic tiles matt finish 10mm thick (square) polished , light shade, area of each tiles exc 0.18 sqm but n.exc 0.38Sq.m in floor etc, set and jointed in neat cement slurry including laid with spacers & pointed with liquid epoxy grout incl 10mm thick screed bed in CM (1:4) complete all as specified and as directed.
Anti skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor etc, set and jointed and laid with spacers and pointed with epoxy and pointed in colour tile grout including screed bed or bedding layer of mortar 10mm thk for laying floor finishes in CM(1:4) complete all as specified
Vitrified tiles coloured (double charged) of 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 0.64 sqm in floors etc, set and jointed in neat cement slurry and jointed with spacers and pointed in liquid epoxy tile grout to match over and including 10mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge”
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed by Engineer-in-Charge”
Factory made heavy duty full body digital matt finish, paving vitrified coloured tiles of size300mm x 300mm x 10mm thick for external use laid over and including 15mm thick screed bed or bedding layer in CM 1:4 including jointed with neat cement slurry and pointed in coloured cement to match the shade of tiles complete all as specified.
Surface excavation n.exc in any type of soil (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified
Excavation in trenches in hard/dense soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed by the Engr-in-charge.
Returning, filling in, under floor including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed by the Engr-in-charge.
TMT bars 10 mm dia and over at to length, bent to shape requiredm including cranking, bending including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified
TMT bars 8 mm dia as in reinforcement or stirrups for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified
75mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring etc, complete all as specified and as directed by Engr-in-charge.
25mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in subbase to flooring complete all as specified.
Providing precast cement concrete 1:1/2:3 in road side kerb stone etc (of any section indicated) with plain fair faces including chamfers. Weathering, throating etc and setting in cement mortar 1:4 complete with joints to match as directed by Engr-in-Charge
PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed by Engineer-in-Charge.
PCC Type B-1 1:2:4 (20mm graded aggregate) (Nominal Mix) in Slabs supported on walls, beams, shelves and the like
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, sides of beams, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed. .
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, using old size bricks, built in cement mortar 1:6 , complete all as specified and as directed. .
All as per item No 31 herein before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
Rendering 10 mm thick cement plaster on fair face of brick work or concrete surfaces of wall in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified.
Rendering 15 mm thick cement plaster on fair face of brick work or concrete surfaces of wall cement mortar 1:4 even and smooth without using extra cement complete all as specified
Rendering 5 mm thick cement plaster on fair face of brick work or concrete surfaces of ceiling in cement mortar 1:3, finished even and smooth without using extra cement, complete all as specified.
Preparation of new plastered surfaces of ceiling and applying three coat of white wash , complete all as specified and directed by Engr-in Charge .
Preparation of new plastered surfaces of wall and applying two coat of cement base paint over one coat of primer , complete all as specified and directed by Engr-in Charge ..
Preparation of new plastered surfaces of wall and applying two coat of oil bound distemper over one coat of primer including 3mm thick wall care putty , complete all as specified and directed by Engr-in Charge ..
Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed by Engr-in Charge .
Taking down chowkats or frames of any type or description (without taking off shutters from frame) not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed by Engineer-in-Charge”
Solid PVC door frame of wallnut colour of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube in opening as per specification and drawings complete all as specified and directed by Engineer-in-Charge”
Factory Made Solid PVC Moulded Door Shutter of wallnut colour , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge”
Powder coated Aluminium Towerbolt Hinges 200mm long match with door shutters fixed to door shutters with screw complete all as specified.
150 mm long aluminium bow handles, cast type, anodised and fixed complete all as specified and directed by Engineer-in-Charge”
300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge”
Butt Hinges 125mm long medium weight cold rolled mild steel and fixed complete all as specified and directed by Engineer-in-Charge”
Taking down chowkats or frames (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed by Engineer-in-Charge”.
Powder coated (of approved colour ) aluminium sections as in frame & shutter of doors, windows (Hung/sliding), ventilators (louvers/fixed type) and fixed frame etc fixed to wall including roller for sliding and necessary locking arrangement, preparation of disturbed portion both side (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) complete all as specified as directed by Engr-In-Charge.
Powder coated aluminium Deco grill DG 202 pattrn with apperture of size 60x45mm securing with suitable aluminium channel to frame complete all as specified as directed by Engr-In-Charge.
Stainless steel mosquito proof wire cloth of stainless 0.36mm dia and 1.4mm aperture fixed with aluminium flat/channel /wooden beading and screws all as specified as directed by Engr-In-Charge.
Glazing with 5mm thick frosted/tinted sheet glass exc 0.50 sqm in each panel fixed to aluminium section of doors, windows and fixed frame with suitable EPDM rubber packing and powder coated aluminium beading to frame complete all as specified.
Stainless Steel friction hinges SS302 grade fancy type fixed with screws to winows shutters to suitable for opening complete all as specified.
Pressed steel frames, size 125 mm x 60 mm. for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 1:2:4, type B-0 using 12.5 mm graded crushed stone aggregates filling inside hollow section etc complete as specified.
Pressed steel frames, size 105mmx60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 1:2:4, type B-0 using 12.5 mm graded crushed stone aggregates filling inside hollow section etc complete as specified.
35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, decorative face veneers on both sides and one face is covered with decorative face veneer with lipping/frame to match and polished on back side and sides of shutters complete all as specified
35 mm thick 2nd class hard wood glazed and skeleton factory made shutters (three panel) open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified
18/19 mm thick Prelaminated particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work with veneered particle board for external teak wood lipping, 6mm thick, fixed with nails 18mm wide complete all as specified.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flaps (When open) 30 mm complete all as specified and directed by Engineer-in-Charge”
Preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and as ddirected ..
MS helical door spring 150mm size including roller and roller plate fixed to wooden or steel frames with welding etc complete all as specified and directed by Engineer-in-Charge”
Door closers of aluminium die cast body hydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kgs and fixed.
Mortice lock with two lever brass body (vertical type) 100mm length of latch with 3 set of keys fixed in door shutter with proper in position complete all as specified.
Stainless Steel 'S' Shape Handles 300mm long Fancy type fixed with screws to door shutters complete all as specified.
Floor door stoper of 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring,
22mm MS dark brown powder coated curtain rod with end brackets and side brackets with designer end pieces fixed with screw and plugs as per directed complete all as specified.
In reapir Wash down water closet (Pedestal pattern), complete with Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.including PVC Seat and cover for pedestal pan . complete Make - CERA cat part No. 2080 (Camelia), Jaquar CNS-WHT-OP01 .or equalvent in any MES APPROVED MAKE
PVC low level flushing cistern of capacity 10 ltr. white with inlet, ball valve, float and handle including breckets, suitable flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipes. CERA cat part No. 2602 P (Camelia), or equilvent of any approved make as approved by GE.
Squatt pattern including cement concrete bedding , size 580 x 440mm including 'P or s trap front and back inlet and with internal foot rests (excluding flushing cistern ) including flush pipe and connector pices of CI Pipe as per required upto T /Y joint. Make - CERA Cat part No-2071/Jaquar CNS-WHT-WCS 1.or equalvent in any MES APPROVED MAKE
In repairs wash basins, vitreous china(flat back or angle back type) size 550 X 400mm, with padestal including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling 32mm and pvc waste pipe 32mm bore complete all as specified CERA cat part No. 1008 (Cornet) for WHB & for pedestal Cat Part No 1108, Jaquar SLS-WHT-0611 F for WHB and SLS-WHT-1510 for pedestal or equilvent of any approved make as approved by GE.
Chromium plated, 15mm WHB Mixer, heavy duty fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge”
Stainless steel soap tray as per sample fixed with wooden gutties and screws to wall surfaces complete all as specified. Make-As per Sample
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge”
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or removal to store (measured overall as fixed along the centre line over fitting and accessories).
PVC (SWR) pipes of bore 110mm single socketed in any length with rubber ring joints laid in floors complete all as specified.
PVC (SWR) pipes of bore 75mm single socketed in any length with rubber ring joints laid in floors complete all as specified.
PVC (SWR) bends with access door any radius of bore 110 mm complete all as specified and directed by Engineer-in-Charge”
PVC (SWR) bends with access door any radius of bore 75 mm complete all as specified and directed by Engineer-in-Charge”
Red granite(of any type)stone slab 16mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding to edges of stone slabs one edg complete Including 10mm thick backing coat CM 1:4 complete all as specified and as directed by Engr-in-Charge.
3 layer rotational moulded polyethylene water storage tanks white colour 500 ltr Capacity (Cylindrical vertical with closed top) with 20 mm ball valve, epoxy coated aluminum rod, plastic ball etc, hoisted and fixed in position including tank Nipple inlet and outlet and conneting pipes including dismantling the existing and removing to store with all fittings all as specified in SSR Part I complete all as specified & as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site to store bore of pipe 15mm.
"-do" but bore of pipe 20mm
Tubes , medium grade of bore size 15 mm including all galvanised fitting accerroies and laid in ceilings or laid in floors complete all as specified and directed by the Engr-in-charge.
"-do" but bore of pipe 20mm.
In replacement bib taps long body 15mm chroimum plated (ISI Marked with valid CML No) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including elbow/socket etc as required at site all as specified and directed by Engr-in - Charge.
Angle cock 15mm chromium plated fittings as required at site and taking down existing unserviceable angle cock all as specified and directed by Engr-in-Charge
Towel Rod CP Brass 20mm bore and 600mm long fixed with screw and plug complete all as specifed
Towel Ring CP Brass fixed with screw and plug complete all as specifed.
Looking Mirror of size 600mm X 450mm X 5mm thick with Plywoof commercial type fixed on back side and wooden frame compete all as specifed.
75 mm bore PVC(SWR) multi/single floor trap with stainless steel grating including jointing to waste pipe fixed in cement with solvent cement, including taking down old PVC or CI floor trap of any type complete all as specified.
Rubbing, stopping of existing surface by using dust free vacuum type grinding machine for removing of old or previously painted surfaces of concrete any description over 10cm width or girth and applying two coat of synthetic enamel paint over including primer and putty touchup repair to cement wall surfaces, complete all as specified.
Stainless Steel hand Railing grade 304SS proper size and shape directed by GE fixed with ss screw bottom round flanges, Stainless steel cleats in floor/walls as as required at site all as specified and directed by Engr-in - Charge.Sample as approved by GE
Stainless Steel Handle 400mm long fies with wall with fasteners complete all as specified.
Applying 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound. Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and providing Atactic Polypropylene polymer (APP) modified five layered prefabricated waterproofing membrane with thermal fusible properties on both side having minimum 3.00mm thick and unit weight not less thaan 4.00kg /sqm reinforced with non woven spun bonded polyester reinforcement < -2 C cold flexibility. The layer of the membrean shall be laid using butane torch and seailing all joints properly ,leaving no bare edgs or end of APP membrane and finishing the surfaces with trowel or otherwise to obtain a unifrom surfaces . The minimum side lap and end lap shall be kept at 75mm and 100mm respectively . The membrane shall be laid over a coat of bituminous primer @ 0.300 kg/ltr per sqm made by the same membrane manufacture after necessary surfaces preparatory works such as cleaning the surfaces throughly,shapping mouth of outlets including cutting grooves (50mm x50mm) in parapat and inserting edgs of membrane and mending goods damage by sand cement mortar (1:4) and shall be finished in all respect and applying two coat of aluminium paint over one coat of primer on roof surface as per directed by Engr-in-Charge. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
Taking down copper/aluminium point wiring (light fan socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors, etc. all as specified and as directed by engineer in charge.
Point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLS in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including sutiable new annealed sunken boxes,modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point/ fan point/ Bell point controlled by one switch including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLS connected to common earth dooly complete including cutting,chasing the surface and then making good the same in CM 1:3 complete all as specified and directed. Make of cable :- Anchor/Havells/ fiinolex and Make of pipe :- Kalinga/Polycab/Havells (Note : Switches, Sockets etc shall be measured and paid for separately under appropriate items of Sch 'A
All as per item No. 96 above but for one 5 Amps socket outlet on independent board.
All as per item No. 96 above but wire size 2x2.5 Sqmm and and providing earth continuity wire using PVC insulated, unsheathed single core stranded copper conductor FRLS cable of size 2.5 Sqmm. to controlled the 3 pin 5 / 15 Amps socket outlet on independent board.
All as per item No. 96 above but point wiring with 1.5 Sq. mm copper conductor, single core, PVC sheathed, cable, to control one 3 pin socket outlet, 5 Amps on the same board with other switch.
All as per item No. 96 above but wire size 2x4 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
Supply and fixing modular switch single pole one way 10Amps 1 module complete all as specified and directed
Supply and fixing modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Supply and fixing modular socket 6 /16 Amps 2/3 pin flush type complete.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as directed by Engineer - in - Charge.
Supply and fixing modular electronic fan regulator, step type, two module 120 watt 230 volt and making all necessary connections complete all as specified and directed.
Supply and fixing modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed.
Switch Piano, flush type, One way, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
Switch socket combination 5 / 15 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the direction of Engr-in-Charge. Make -Make of LED -SYSKA as per ordering code SSK-ALB-20W or equivalent model of Havells or CG
In replacement Slim linear LED lighting fixture 5/6W watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge. Make -Havells Cat No : LHEXBYPNIN1W005 or Wipro Cat No: D530565 or equivalent C&S Cat No: LTTBIF5WLED/W
Slim linear LED lighting fixture 18/20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 36/40W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make -Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ PHILLIPS BAJAJ
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Repair of ceiling fan 1200mm sweep of any make obtained from above item, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed by engineer in charge.
Earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on complition with following:-(a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
Wiring for circuit / Submain Wiring in and including no metalic PVC concealed conduit not less than 25 mm dia with 2 x 6 Sq.mm main wire and 1 x 6 Sq.mm earth wire of FR, PVC insulated copper conductor, single core cable complete all as directed by Engineer - in - Charge.
Taking down old unserviceable copper / aluminium submain wiring any type / size from existing old surface for further repair / replacement complete all as specified and directed by Engineer-in-Charge”
Taking down serviceable/unserviceable MCB DB of any type and capacity with MCB etc after disconnecting for re use or for credit all as directed by engineer in charge.
In replacement single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and directed by Engineer-in-Charge”
Supply fixing connection and testing MCB SP6-32, 10kA Amps complete all as specified and directed by Engineer-in-Charge”
S&F 'C' series SPN MCB 40 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc complete all as specified and directed by Engineer-in-Charge”
Fixing only serviceable AC Boc of any type/ Any capacity complete all as specified and directed by Engineer-in-Charge”
Supply and fix sheet metal enclosure double door single pole and neutral 240 Volts for DB's when MCBs to be used 8 way with 200 amp rated bus bar with IP-43 protection. MakeLegrand Cat Part No 607711 complete all as directed by Engr-in-Charge.
Supply fixing, connection and testing MCB SP6-32 Amps C series, breaking capacity 10 KA of rating 6-32Amps complete all as specified and directed by the Engr-in-charge.
Supply fixing, connection and testing MCB SPN 32-63 Amp, 240 Volts, 'C' series, breaking capacity 10 KA of rating 32-63Amps complete all as specified and directed by the Engr-in-charge.
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cuttingof bituminous road/chasing to any surface and making good to the disturbed surface to match the existing complete all as specified and directed by the Engr-in-charge.
Dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as complete all as specified and directed by the Engr-in-charge.
GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and directed by the Engr-in-charge.
Switch socket combination 5/15 Amps, suitable for 240V 50Hz suitable for 240 V, 50HZ AC supply complete all as directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 20W new generation energy saving & environment friendly long life versatile pressure die-cost aluminium P-86 with acrylic with hear resistant toughened glass corrosion resistant complete making all connection with MCB SPN alongwith MCB Box enclosure GI tubing light grade 25mm dia lenght 1.2 mtr clamp, bolts, nuts and washers complete with testing all as specified and direted by Engineer-in-Charge.
Supply and fixing fans ceiling complete with electronic type regulator and accessories 230V, 1200mm sweep 6-32 Amps complete all as directed by Engineer-in-Charge.
SHIVAE CONSTRUCTION
MADAN LAL SHARMA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .