Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹72.0 L+₹1.6 L (2.32%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹73.3 L+₹2.9 L (4.17%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹44,400
Closing Date
15 Oct 2024, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer PWD Buildings C and M Circle Tirunelveli
Providing Internal and External Electrification to the Additional Building (Maternity Child Health block) in Government Hospital at Vilathikulam in Thoothukudi District
2024_PWD_489799_1
10(2)/2024-25/dt.20.09.2024
Open Tender
Electrical Works
Lump-sum
210 days
Vilathikulam, Thoothukudi
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹44,400
11 Dec 2024
1 Oct 2024
16 Oct 2024
1 Oct 2024
15 Oct 2024
1 Oct 2024
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil)(Higher End)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator). (For Lift shaft)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Wiring with 3 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Modular Light point (Higher End)
Supply and run of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing PVC rigid pipe.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point (8 points / Coil) Higher End
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point (For Lift shaft)
Supply and fixing of single box type 4' 20W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20W LED tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. (Higher End)
Supply and fixing of 24W LED square type Surface mounting fitting (Havells Integra Nxt DL / Eq) with Aluminium (99% Purity) Sink, available in Sqaure shape. PC diffuser in white powder coated finish with built in electronic low THD (<10%) LED driver 6500K CCT; CRI ≥ 80 with 1.5 sqmm PVC unsheathead FRLS copper wire from terminals to the fitting and necessary connection complete.
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of batten holder (bakelite) with 9W LED lamp.
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.
Supply and fixing of 100W LED flood light (Higher End) with integrated driver with suitable angle iron frame work on wall / post with necessry connection complete.
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300mm (12”) sweep (light duty) AC Exhaust fan.
Supply and fixing of 400 mm (16") sweep wall mounting fan (Orient Electric Wall-49 / Eq) with remote with suitable clamps and necessary conections complete.
Supply and fixing of 1no. 6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End
Supply and fixing of 2 no. 6A two module socket, 1no.6/16 A two module socket , 2 nos. 6A one module switch, 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
Supply and fixing of 32A, 10kA Double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and fixing of 32A, 10kA FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).
Supply and fixing of 7 segment 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 25A 4 pole MCB as incoming and 3Nos 25A DP RCCB as sub incomer and 12 Nos. 6 A to 20 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)
Supply and fixing of 7 segment 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 40A 4 pole MCB as incoming and 3Nos 40A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board (with MCB incomer) with double door (metal) with 1 no.100A FP MCB switch as incoming and 4nos.63A TP MCB & 4nos.32A TP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed portion.
Supply and erection of 200A capacity dust and vermin proof cubical panel board of suitable size made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interior switch with bus bar chamber complete with 1"x1/4" tinned cu. Flat for 3 phases & neutral and earth connections with bus bar insulators complete with the following tinned Cu flat should be used between busbar and switches : 1"x1/4" tinned cu. Flat for interconnection of 2nos 200A incoming switch to bus bar with interlocking arrangements,
1. 200A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos with interlocking arrangements. 2. 100A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos 3. 63A TPN switch disconnector fuse units interior only with HRC fuses double break-6 Nos
In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylem sheet sepearator, and properly earthed by tinned solid copper flat as I.E rules CEIG specifications. The earth bus with two runs of 1"x1/4" tinned copper flat must be run all round the panel to provide double earth connection.
The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size capcity of switch loaction etc, should be marked with white paint and metalllic danger board affixed complete with mounting on base channel 3" x 1 1/2" x 1/2" iron frame work support complete (The TPN switches should be L& T/ siemens make only.) (Incoming supply)
Supply and fixing of 200 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of dust and vermin proof cubical type LTCT metering box of size 3ft x 1 ft x 4ft made of 16SWG CRCA sheet steel with door, lock and key arrangement with angle iron support comprising of three compartments for 3 phase energy meter with base plate & view glass arrangements, bus bar arrangements with 1" x 1/4" insulated tinned Copper bus bar for 3phases & neutral with provision for CTs and sealing arrangements as per TANGEDCO norms
and 3nos 250A (500V) fuse units and MS cable entry box. The earth bus with two runs of 1" x 1/4" tinned copper flat must be run all round the panel to provide double earth connection.The buses should be mounted on the SMC bus insulators with proper spacing and should be provided with heat shrinkable sleeves using RYB & Black colours.The bus bar chamber should be segregated from the adjacent chambers by providing 12mm thick hylem sheet. The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size, location etc., should be marked with white paint affixed with Danger sign with 19/16 PVC insulated Cu wire interconnection from meter to fuse unit and necessary connection complete cconfirming IE rules.
Supply and fixing of 63A, 10kA FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).
Supply and clamping of 3-1/2 x 35 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. aluminium PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 35 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and clamping of 3-1/2 x 150 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 150 sq.mm. aluminium PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 150 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and fixing of 65mm (2½") G.I. pipe (Class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting & masonry work for fixing the post (for cable tray)
Supply and fixing of 150mm width x 50mm height GI Hot dip galvanized powder coated 16SWG preforated cable tray on ceiling or wall with suitable fastereners, bolt nuts, clamps and necessary connection complete.
Earthing as per the ISI specification with an earth electrode of 2.10 metre class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Earthing as per P.W.D standard with an earth electrode of 2metre Class'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/ supports on wall/ floor/ ground for earth connection
Supply and run of 1 of No.8 SWG GI wire for earth connection
Supply and fixing of 2kVA single phase in & single phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1 hour backup along with Powder coated MS Rack and interlink cables with following specifications:
1. Output Voltage Range : 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode 6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action
7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery. (Microtek / Numeric make / Eq), (Battery make : Exide)
Design, Engineering supply, fabrication, erection, testing, commissioning and handing over of 20 persons capacity Bed-cum-Passenger Gearless Lift with M/C room, Speed 1 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD as per the following Technical specifications
1. Location: Government Hospital -Additional Building ( Maternity Child Health Block) (G+2) 2. No of Lift : 1No 3.Type of lift : Hospital Lift 4. Capacity of lift : 20 persons capacity (1360Kgs)
5. Speed : 1.0 m/s 6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions.
7. No. of floors: (Ground + 2 floors) 8. Total Travel : 7.2 mtrs. 9. Leveling Accuracy: High level accuracy with smooth & jerk free stopping 10. Construction of Car: Car Panel with High quality SS 304 grade car Neat hairline finish, S.S 304 grade hand rail, Perspex false ceiling, stretcher impact protection. 11. Position of machine: Directly above the lift well. 12. No. of landing entrance: 3 Nos (one in front only) 13. No. of car entrance: one in front only 14. Car entrance door: power operated V3F drive side opening sliding SS 304 stainless steel hair line finish. 15. Landing entrance door: power operated V3F sliding, opening 18SWG stainless steel 304 grade hair line finish with provision for emergency key
25. Indication: UP/Down digital direction and position indicator for all landing and in car 26. Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 27. Emergency light: Battery operated light to be provided with Automatic charging device. 28. Fireman’s switch: To be provided at ground floor 29. Minor builders work: to be provided by lift contractor. 30. Scaffolding: to be provided by lift contractor
31. Sill angles and facia plates: to be provided by lift contractor 32. Steel for lift machinery: to be provided by lift contractor 33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by the lift contractor during the guarantee period of one year. 34. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, inverter, under voltage protection system etc., complete with all accessories.
35. Provision of intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor annunciator with music, included
38. Special features: a. Infra red door sensor with full height screen. b. Tubular S.S hand rail in cars. c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vendal proof S.S. Button with S.S. cover f. SS hairline finish door frames for landing doors.g. VF door Register signal h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. Steel ladder for machine room and ladder for lift Shaft pit, k. On – Off switch for fan and light l. Over load warning indicator With audio announcement.
39. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries.
40. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 42. Site testing in accordance with IS 14665 as amended should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 43. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. (Johnson/KONE/ OTIS) (G+2)
Design, supply, installation, testing and commissioning of 8.5TR Nominal capacity DX Air-cooled Condensing unit fixed with energy efficient R410A Refrigerant scroll compressor along with grooved copper tube/aluminium fins air cooled condensor coil with anticorrosion coatings, liquid, accumulator, low noise alumimium propeller condenser fan with Fan motor etc all suitably assembled neatly in heavy duty GSS sheet metal cabinet and duly powder coated as per specifications. The unit to include built in safety controls like HP/LP switch power quality protector, in built thermal / temperature protection
Supply, installation, testing and commissioning of 3400 Cfm 8.5 TR Nominal capacity factory assembled double skin ceiling mounted AHU with 50mm-45kg/cum PUF Insulated detachable panels, extruded thermal break aluminium profiles filled with PUF, panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts,
prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 mic, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins ,GI mist arrestor ,condensate coil trough with SS-304-20G insulated with 9mm closed cell elastomeric foam, guard for inspection door ,out let damper of aerofoil blades &PVC gears ,and flexible fire retardant canvass complete with galvanized hardware.
Supply and filling of R410A Refrigerant Gas.
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 28.60 mm size
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 15.9 mm size.
Supply and fixing of flexible Canvas connection.
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 22 Gauge thickness.
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 24 Gauge thickness.
Supply and providing thermal insulation of 9 mm thick vidoflex with Aluminium Foil.
Supply and providing Acoustic for initial portion of Ducting with 12mm thick fiber glass rigid board covered with Tissue Paper and Aluminium Perforated Sheet.
Supply and fixing of extruded Aluminium powder Coated, supply and return Air Grilles / Diffusers with volume control dampers.
Supply, installation, testing and commissioning of Laminar Flow arrangements with HEPA Filters, Frames, etc. 8 ft X 6 ft for OT Ceiling Suspended provides ultra clean sterile CLASS 100 clean air and designed as per CLASS 5 OF ISO 14644-1 standards with air plenum at Aluminium powder coated 1mm thick casing with Aluminium pleat HEPA filters & 0.3 micron 99.97% efficiency and SS 304 perforated grill with 13 mm thickness XLP Insulation with Modular Housing, Frame: Aluminium, Flange type, Filter Media: Micro glass fibre, Sealant : Plolyurethane with Air flow as per standards suitable for 8.5 TR.
Supply and fixing of 1" PVC water drain pipe line.
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Indoor Unit.
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Outdoor Unit.
Supply and providing of pipeline nitrile rubber insulation for refrigerant and drain pipe lines
Supply and providing of 0.5sqmm 4 core flexible signal cable
T PAULKANNU & CO (BID ID -1163703)
ANNAI ELECTRICALS (BID ID -1163558)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .