Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.9 L+₹3.0 L (15.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.2 L+₹4.3 L (21.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Nov 2019, 6:00 pmClosed
GE (AF) Jammu
GE (AF) Jammu Air Force Station Jammu
REPAIR/REPLACEMENT INCLUDING DAY TO DAY MAINT OF STREET LIGHTS, SECURITY LIGHTS INCLUDING FLOOD LIGHTS IN DOMESTIC AREA AT AIR FORCE STATION JAMMU
2019_MES_281325_2
CA NO GE/AFJ-38/2019-20
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Jammu
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹40,000
Yes
22 Jan 2020
21 Oct 2019
25 Nov 2019
21 Oct 2019
23 Nov 2019
7 Nov 2019
Amount
Petroling and attending day to day complaints and maint/repairs to street light/security light fittings/Garden light/ Post top lantern light fitting of any type and capacity fixed at any height by replacing unserviceable parts of the fittings such as lamps. tubes, etc and connecting to main to make the fitting serviceable including cleaning of perpex cover, checking loose connections, power supply problem, etc. detecting and repair of under ground cable fault etc as and when required round the clock complete all as directed at site on daily complaint basis. Note: 1. Due to security point of veiw one electrician with helper shall be present daily round the clock with required T&P, spares and transport for attending unserviceable security/street light complaints received from users. The Contractor will ensure attendance of electrician and helper before JE E/M and the same will be produce before Engineer-in-Charge for payment. Note 2. Repair/replacement of spares/loose connection of particular fittings shall be measured and paid as one job for one day irrespective of any numbers of complaints attended in a particular day. 3. Street light complaints should be attended and rectified within the same day failing which recovery at double the rate quoted by contrator against this item shall be affected from his becoming due's
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
Taking out of old serviceable/unserviceable PVC under ground LT cable of any size and type fixed on pole, wll or laid in floors, trenches, across road crossing, etc. including taking out cable covers of precast PCC/RCC slab or brick covers, etc., including setting a side serviceable materials in safe costody for reuse and or unserviceable materials shifting to store complete all as specified and as directed. Note: (i) Dismantling of clamps, nuts, bolts, etc., taking out of GI pipe in cable protection shall be measured and paid separately under respective item of this schedule. (ii) Cost for making good the disturbed ground surfaces of floors/walls in cement mortar 1:3 shall deemed to be included in the unit rate quoted. However cost for making good the disturbed surfaces of roads with PCC and hard core filling is out of scope of this work and shall be measured and paid separetely under respective item of this schedule.
Relaying only of serviceable LT under ground cable of any size and any type in trenches, floors, across road crossing or fixed on poles, walls, or passing through pipe, cable obtained from ser item No 10.00 here-in-before complete all as specified and as directed by the Engineer-in-Charge. NOTE: Handling of under groucn cable to working site as ordered shll be carried out by the firm and rate for the same is to be deemed in overall rates quoted by the tenderer under this item.
Relaying only of serviceable bricks/PCC slab cover obtained from item No 10.00 here-in-before for cable protection cover laid width wise along length of cable complete all as specified and as directed by the Engineer-in-Charge.
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, incl taking down carefully old deterioiated RCC/steel pole etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables, foundation of poles, etc. complete. Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site which will be handed over to the appropriate authority as directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth and getting out in any type of soil for laying of LT UG cables, foundation of poles, etc. complete. Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site which will be handed over to the appropriate authority as directed by Engineer-in-Charge
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard dense soil
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation and mass concrete of poles complete all as specified and as directed.
PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified & directed.
Supply and Fixing GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing GI tubing light grade 80mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing round PVC Insulated copper Conductor stranded (Flexible), industrial cables PVC Sheathed Cables Nominal area of conductor 2.5 Sqmm, 2 Core, 1100 volts to IS: 694 complete including taking old unserviceable cable all as specified and directed. Make : Havells/Polycap/Plaza/Gloster
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 16 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 25 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 35 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 50 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 70 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 95 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 120 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 185 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 240 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 400 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position, extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply and fixing Edge series Powder coated pressure die cast alluminium compact high power LED street light fittings with heat resistant toughned glass with lense having 45 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat Part No: 169799 BRTFG 45W LED WW of Bajaj or equavalent to Havells/ Crompton
Supply and fixing Edge series Powder coated pressure die cast alluminium compact high power LED street light fittings with heat resistant toughned glass with lense having 60 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat Part No: 169950 BRTFG 60W LED V3 WW of Bajaj or equavalent to Havells/ Crompton
Supply and fixing Edge series Powder coated pressure die cast alluminium compact high power LED street light fittings with heat resistant toughned glass with lens having 90 Watt with lens including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make :Cat Part No: 169800 BRTFG 90W LED I WW of Bajaj or equavalent to Philips/havells/ Crompton
Supply and fixing Magnum LED flood light die cast alliminium housing complete with all accessories IP66 high power LED floodlight 100 Watt incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make :Cat Part No: 169904 BJFL 100W LED I of Bajaj or equavalent to Philips/havells/ Crompton
Supply and fixing Turbo LED flood light die cast alliminium housing complete with all accessories IP66 high power LED flood light 120 Watt incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make :Cat Part No: 169641 BARFEG 120W LED I WW of Bajaj or equavalent to Philips/havells/ Crompton
Supply and fixing decorative LED post top lantern 40 watts light fitting including lamp for 360 degree indirect light, resistant to impact and corrosion glare free and better informity IP 65 protection, M-Milky version and including necessary connection with suitable size cable, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat Part No: LPTO-40-CDL/M of Crompton or equavalent to Philips/Havells
Supply and fixing in repairs street light bracket 1.50 mtr long made out of 32 mm bore GI pipe, light grade, bend to shape, welding etc and fixing on existing LT pole with 50 x 6mm flat iron MS clamps including necessary nuts, bolts and washers etc and including painting two coats with synthetic enamel paint over a coat of red oxide primer after removal of galvanising with moderate solution complete all as specified and directed.
Supply and fixing LED aviation light of 40 watts including necessary connection with two run of 1.50 sqmm single core unarmoured copper cable from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Bajaj Cat Part No BGAV 302 LED or equavalent make of Crompton/Philips/Havells/C&S
Supply and fixing fixed in repairs cable Junction Boxes with terminals` IP 66 "halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) Cable Size 16/25 Sqmm, Box Dimensions-200 x160 x 98, Catalog No-KF 9255(hensel) complete taking out of loop of cable from ground by neccessary earth work all as spcefied and directed by Engr-in- charge. Make- Hensel/Dowells
Supply and fixing in repairs PVC cable end terminal box outdoor type, 140 x 140 X 95 mm, PVC door, Sintex type , provision for cable incoming and outgoing from bottom, comprising of one MCB SPN 6-32 Amps (of Make: Legrand/Schneider/L&T), cable glands suitable size and one porcelein connector four way complete fixed on wall/pole. Make- Sintex of equivalent.
Supplying and fixing multi stranded 04 sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing multi stranded 10 sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Sub main wiring with two single core PVC insulated unshesthed cable copper conductor (FRLS) of size 2.5 sqmm multistranded and one run of 1.5 sqmm PVC insulated unsheathed copper conductor (FRLS) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.)
Supply and fixing Rigid non-metallic PVC conduit 25mm dia (Heavy duty) in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed. Note: This item shall be measured and paid for the locations other than the locations measured under item No 48.00 here-in-before.
Supply and Fixing LED bulb 7 watt, B22 Base (6500K), pin type, lumino for normal batten holder/pendant holder at any height as per requirment of site including taking down old unserviceable light, complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No Havells Adore LED-7W or equivalent in Bajaj/Philips/CG
Supply and Fixing Change over switch On load 315 Amps 4 pole with sheet metal enclosure, fixed in repairs complete all as specified and directed. Make: Indoasian Cat Part No ICASO320 or equal approved in Siemens/Havells/Legrand.
Supply and Fixing MCCB 320 Amps 4 pole 36 KA with thermal magnetic release, fixed in repairs complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4220 06 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and Fixing MCCB 250 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting, fixed in repairs complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4202 19 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fixing MCCB 160 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting fixed in repairs complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4200 56 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply & Fixing MCCB 100 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting fixed in repairs complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4200 55 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fixing MCB SPN 40 Amps, 230 V,AC complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 18 of Legrand (DX³) or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SPN 25 Amps, 230 V,AC complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 16 of Legrand (DX³) or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply, installation, commisssioning and testing of street light TIMELITE distribution boards, timelite 40 Amps 3 pole astronomical time switch suitable for 230 volts 3 phase 4 wire with locking arrnagement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts and washers etc. complete all as specified and as directed by Engineer-in-Charge. Make: Indoasian HSN Code 8537 Cat part No TL040ASO or equal approved make as specified in particular specifications.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium paint, including taking down old broken steel complete all as specified and directed by Engr-in-Charge.
Supplying, laying and spreading (thickness as directed by Engineer-in-Charge) dry/loose coarse aggregates (granite, trap, Basalt), grading I, 90 to 40 mm or grading 2, 63 to 40 mm size, including well ramming, under 2/4 pole structure including cleaning and uprooting the wild grass and other vegitation, complete all as per direction by Engineer-in-charge.
Preparation of old painted surface of HT steel tubular poles above the top of PCC coping. Painting of pole from top of coping to a height of 1.5mtr (bottom portion of pole) with two coats of synthetic enamel paint (Make-DULUX/ Superlac (Shalimar)/ Apcolite (Asian)/ Nerolac/ Luxol (Berger) in black and yellow alternate strip and painting the rest portion of pole of (approx length 9 mtr) including painting of cross arms/clamps etc complete with two coats of synthetic enamal aluminium paint (Make-Asian (Apex)/ Berger (Weather Coat) /Shalimar (Ist quality)/ Nerolac (Ist India) and to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
Preparation of old painted surface of LT steel tubular poles above the top of PCC coping. Painting of pole from top of coping to a height of 1.5mtr (bottom portion of pole) with two coats of synthetic enamel paint (Make-DULUX / Superlac (Shalimar) / Apcolite (Asian) / Nerolac/ Luxol (Berger) in black and yellow alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paint (Make-Asian (Apex) /Berger (Weather Coat) / Shalimar (Ist quality) /Nerolac (Ist India) and to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
Preparation of old cement based painted surfaces of RCC pole 9 mitres long by complete removal of existing treatment and painting with two coats of exterior emulsion weather proof paint of approved make and colour all as specified and to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
Material and labour for repair to existing LED street light fitting 45 Watts to 120 Watts of any make including supply and replacement of driver, LED Strips and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge.
Material and labour for fault detection in damaged under ground cables using cable fault detector/locater, vehicle mounted to accuracy of 2 mitres for various locations inside Air Force Station for under ground cables of any size upto 240 sqmm including excavation and earthwork in any type of soil having trench size 4 x 2 x 0.60m to visually inspect/ repair the damaged cable when and whre detected complete all as specified and directed by Engineer-in-Charge. NOTE: cable fault shall be located with use of cable fault locator machine as and when required with minimum possible time to reduce the downtime. If fault is not attended/located within 24 hours, recovery will be made at Rs 4000.00/Day from the date of such occurance.
Cable jointing kit for 1100 Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 35 sqmm fixed in repairs,complete all as specified and directed by Engineer-in-Charge. Make: 3M/Denson/M-Seal
Cable jointing kit for 1100 Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm fixed in repairs,complete all as specified and directed by Engineer-in-Charge. Make: 3M/Denson/M-Seal
Cable jointing kit for 1100 Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm fixed in repairs,complete all as specified and directed by Engineer-in-Charge. Make: 3M/Denson/M-Seal
Cable jointing kit for 1100 Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm fixed in repairs,complete all as specified and directed by Engineer-in-Charge. Make: 3M/Denson/M-Seal
Supply, installation, commissioning and testing of LT feeder pillar, compartmentalised design of sie not less than 70 x 70 x 25 cm suitable for 440 volts 3 phase 4 wire system made out of 2.5mnm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts and washers, etc. with mounted accessories including the following components fixed in repairs,complete all as specified and directed by Engineer-in-Charge. (a) Four 30cm long copper bus bars 400 Amps mounted on epoxy insulators provided with rust proof nuts, bolts and washers. (b) LED indicating lamps - Set of three (Red, yellow, Blue)
Cutting of tree branches of any girth along HT/ LT OH lines & street light pole at a distance not less than 2 meter on either side of the pole cleaning of bushes and shrubes of any type along entire RM of poles. Cleaning /prunning should be carried out as and when required during entire running period of contract or as and when directed by Engineer-in-Charge. A fine of one time quated rate per running meter will be deducted if the over growth is found along the pole all as directed by Engr-in- Charge.
Cleaning of under growth at substation . Cleaning should be carried out as & when required or when directed by Engr- in-Charge. Undergrowth at any point of time should not be more than 3 to 4 cm. A fine of Rs 1000.00 per month per substation will be deducted if undergrowth found grown beyond permissible height complete all as directed by Engr-in-Charge.
Material and labour for earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wire complete all as specified and directed by Engineer-in-Charge.
Material and labour for earth continuity conductor or main earthing lead using 25 x 4mm galvanised steel strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, etc. as required including porcelain insulator saddle at the spacing nort exceeding 400mm including taking down old strip complete all as specified and directed by Engineer-in-Charge.
Material and labour for earth continuity conductor or main earthing lead using 32 x 6mm galvanised steel strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, etc. as required including porcelain insulator saddle at the spacing nort exceeding 400mm including taking down old strip complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-
(a) Excavation and earth work for drilling hole for electrode in any type of soil.
(b) PCC pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
(e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.
(f) Requisite quantity of common salt and charcoal.
(g) Testing of earthing.
Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 32 x 6 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-
(a) Excavation and earth work for drilling hole for electrode in any type of soil.
(b) PCC pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
(e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.
(f) Requisite quantity of common salt and charcoal.
(g) Testing of earthing.
Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the Air Force station area
VIDHATA ELECTRICALS
M/s Mohan lal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .