Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.9 L+₹3.0 L (9.86%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.3 L+₹8.4 L (28.1%)Rejected-Finance WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹44.6 L+₹14.7 L (49.1%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.7 L+₹14.7 L (49.3%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
7 Dec 2021, 6:00 pmClosed
GE (North) Delhi CAantt-10
GE (North) Delhi CAantt-10
REPAIR MAINT OF MISC BR WORKS OF JOINERY LEAKAGE SEEPAGE PLASTERING ROOF TREATMENT PLUMBING ETC AND MISC EM WORKS IN MD ACCN AT STATION ROAD MAUDE ROAD MALL ROAD IN AREA OF AGE BRII UNDER GENORTH DELHI CANTT 10
2021_MES_486282_1
GE/NORTH-44/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (North) Delhi CAantt-10
AS per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (North) Delhi CAantt-10
₹98,000
Yes
23 Dec 2021
3 Nov 2021
9 Dec 2021
3 Nov 2021
7 Dec 2021
24 Nov 2021
Amount
Taking down chowkhats or frames with shutters(without taking off shutters from the frames) n.exc 1.5 sqm each and remove from site complete all as specified and directed.
Taking down chowkhats or frames with shutters(without taking off shutters from the frames) exc 1.5 sqm and not exc 4 sqm each and remove from site complete all as specified and directed.
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each and removing to store complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) frame works for doors, windows, ventilatiors and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief. Note - The rate includes the cost of the materials and labour involved in all the operations described above for fixing of frame/ partition.The cost of anchor bolts or screws for joining the frame is included in the rate. Only any other hardware( i. e. tower bolt, sliding door bolt, handle , Glass etc), which may be required, shall be paid for separately.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with truded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief. Note - The rate includes the cost of the materials and labour involved in all the operations described above for fixing of shutters.The cost of anchor bolts or screws for joining the frame is also included in this rate. Only any other hardware ( i. e. tower bolt, sliding door bolt, handle , Glass etc), which may be required, shall be paid for separately.
S & F in repair for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in-charge.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash xtruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
S&F solid PVC door frame of size 50 mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing.
S&F Factory made solid PVC moulded door shutter (with particle board core) , 28 to 30 mm thick (stiles) , with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded prelam PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed.
S&F 125 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed.
S&F aluminium anodized barrel tower bolts of extruded section of length 150mm , complete all as specified and directed.
S&F aluminium handle cast type anodized 150mm, complete all as specified and directed.
S & F 300 mm long Mild steel sliding door bolts plate type, store enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Supply and fix in repair door closer hydraulically regulated,of aluminium(Die cast) body universal type suitable for door shutters 851 to 1000mmin width and weight between 61 to 80kg of Hydraulic door closer complete all as specified and directed.
S&F glazing of tinted glass 5.5mm thick in aluminium door window shutters and partitions etc with PVC/neoprene gasket etc Complete all as per specified and directed by Engr-in-Charge.
S&F galvanised stainless steel wire cloth, 0.36 mm nominal dia of wire and averege width of aperture 1.40 mm, complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
M&L for 15 mm thick Ready Mix Plaster in CM 1:4 mix with proper water ratio on faces of brick or concrete surfaces finished even and smooth in mixed with water proofing compound complete all as specified. (Water proofing compound shall be measure and paid separatelly). (Make:- Ultra Tech, ACC, Birla)
M&L for rendering 15mm thick Ready Mix Plaster of faces of brick or concrete surfaces in cement mortar 1:6, finished the surface even and smooth without using extra cement all as directed and specified. (Make:- Ultra Tech, ACC, Birla)
Material & labour for preparation of newly plastered surfaces of any description and applying two coats of cement base paint over a coat of primer all as specified and directed.
Providing and applying plaster of peris putty of 1 mm thickness over plasterd surface to prepare the surface even and smooth , complete all as specified and directed.
M & L for finishing walls with Acrylic Smooth exterior paint ( approved make) of required shade or colour ( approved by GE) over new plastered finished surface (Two or more coat [email protected] Ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , Complete all as specified and directed.
M&L prepartion of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer and 3mm thick of wall care putty of make birla/JK, all as specfied and directed.
M&L for preparation of old decorated surfaces of any description and applying one coats of cement base paint on external wall surface complete all as specified and directed. ( Height of Bldg is upto 15 mtr )
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in plinth protection / pavment and the like, finish the surfaces even and fair without using extra cement all as directed and specified
M & L machine precast colour concrete decorative interlocking paver block of a with grey cement and pigment any shape and size confirming to IS15658-2006 of 60mm thickness M-35 Gde complete all as specified.
M & L sand filling under floors including watering and consolidation.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, 75mm thick as in sub base cemplete all as directed and specified
M/L cement concrete type B-1, 1:2:4 using 20mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding including racking of joints haking for key and scrubbing down with water etc complete and removal of rubbish out side MD land complete all as specified and directed.
M&L double charged vetrified dark shade tiles 10 to 15 mm thick (square/rectangular polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white cement to match incl over 15mm thick CM 1:6 screed bed for laying floor all as specified and directed.
Ditto all as per item No 34 but on vertical surface as in dados/skirting over 10mm thick plaster as backing coat in CM 1:4 all as specified
M&L for glazed ceramic joint free coloured tiles of size 300mm x 450mm 7mm thick in vertical surface such as dado, skirting etc set and jointed in neat cement slurry and pointed in white orcoloured cement to match the colour of tiles over and including layer 10mm thick in cement mortar 1:4 complete all as specified and directed .
S & F in repair toilet paper holder of brass, chrominum plated fixed to wall with CP brass srew as as specified and directed in Engr in Charge.
S& F in repair composite pattern vitreous china wash down closet, One Piece Closet Western Commode, Cat part No 92503 ,including seat cover and all fittings Complete all as specified and directed. Make – hindware or equivalent
S&F in repairs vitreous china, wash hand basin with Half pedestal , size 550x400x200mm including MS brackets including cutting and priming in with 32mm CP waste coupling and bottle trape complete all as specified and as directed. (Make Jaquar CNS-WHT-801)
S&F in repairs Single Lever Wall Mixer with Provision For Overhead Shower With 115mm Long Bend Pipe On upper Side, Connecting Legs & Wall Flanges.(Make Jaquar KUP-35117PM) complete all as specified and directed.
S&F in repair Single Lever Basin Mixer without Popup Waste System with 450mm Long Braided Hoses & Base Flange (Make Jaquar KUP-35011BPM ) complete all as specified and directed.
S&F in repairs two way angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions.Make Jaquar or Equavalent ROCA
S & F in repair 2 way bib cock with wall flange cast copper alloy C.P with non corrosive coating 15 mm bore screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union all as directed and specified. Make Jaquar Cat part no. ALI 85041 ) or equivalent
S&F in repair premium quality frameless looking glass mirror, 5 to 6 mm thick , with all necessary fittings for fixing at wall , complete all as specified and directed. Make- Modi float or equivalent
M&L for preparation of old decorated plastered or unplastered surfaces of wall and applying two coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds,filling gaps wth wall care putty, complete all as specified and directed.
M&L for preparation of old decoreated external wall surface by sand paper of required sizes , filling in wall care putty in pot holes existing or created ,again sand papering thus making surface smooth and one coats of weather proofing exterior acrylic emulsion paint complete all as specified and directed .
Dismantaling wrought iron or mild steel work of any description not otherwise provided for all as specified and direcred.
S&F Steel Work for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) ,round or square pipes including distance pieces etc.all as specified and direcred.
S&F steel work in tubler trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade st-240 all as specified and direcred.
M&L for MS Plates, plain or chequered, of any thickness as in gusset plate , cover plate etc in thickness in available sizes for Gde-Fe-410-W Gde-E-250 qulaity B all as directed.
Material and labour preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Dismantaling plain or corrugated AC sheeting any gauge, thickness, including nainital or similar pattern roof covering all as specified and directed..
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, ridges, velly gutters fixed with self tapping screws complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets & any type of frame work.all as specified and directed.
S&F GI powder coated frame work of size 605 x 605 mm, for celing comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs complete all as specified and as directed.
M & L 4 mm thick size non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminiumframe work with screws complete all as per manufacturers instructions and as directed.
S & F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent and fixing at site on PVC frame all as specified and directed by Engineer-in-Charge.
M & L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as directed by Engineer-in-Charge.
S & F 5mm thick Looking Mirror mounted over 18mm thick block board, with decoratve beading around mirror & fix to wall with steel fasteners @ 1200mm C/C all as specified & directed.
M/L for preparation of old , rusted steel surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer all as specified and directed.
S & F in repair Toughened glass ( 10 mm thick ) as in hinged door , partitions, automatic doors and similar work incuding cutting to shape , drilling holes incuding all required fitting and fixctures etc complete all as specified and directed.
Demolition of brick/stone masonry built in CM. all as specified.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all as specified and as directed .
M&L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed.
Demolition of cement concrete (unreinforced) as in Roof , floors ( other than ground floors) beams, staircases, landing , chajjas and similar suspended work and Removing excavated material n exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point all as speicified and directed by Engineer-in-Charge.
Cutting grooves in brick wall , 75 mm wide and 65 mm deep and shaping horinzontal face of groove with cement mortar 1:3 , complete all as specified and directed
M & L for PCC type B1,1:2:4 ( 20mm graded stone aggt) in roof slab or as leveling course using integral WPC admixer @200 ml/bag of cement comlete all as specified and directed (WPC will measured and paid seperatly)
Complete removal of old roof treatment incuding cement mortar ( except mudfushka , brick tile ) and removal of grass, small trees by picking sweeping , cleaning and washing down with water to remove dust etc incuding removing debries out side MOD land , complete all as specified and directed.
M&L for 15 mm thick Ready Mix Plaster over the concrete/ brick roof surfaces in cement mortar 1:4 mixed with liquid water proofing compound @ 200ml per bag WPC (liquid type) , surface finished even and smooth without using extra cement all as specified and directed. Note :- Water proofing additive shall be measured and paid separately.
M & L for applying a priming coat of @ 0.30 Kg / Sqm with Bituminous primer including prepration of surface , complete all as specified and directed .
M & L for applying evenly a tack coat of industrial hot blown grade bituminen 85/25 @ 1.2 Kg/Sqm including cleaning surfaces over primer ,complete all as specified and directed.
M & L for water proofing treatment of roof with APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) shall be laid with 100mm side lap/end lap on primed surfaces as per manufacturers instruction , complete all as specified and directed.
M& L for applying a coat of heat resisting paint ( aluminium bitumen paint) over APP surface, complete all as specified and directed .
Supply only Liquid integral water proofing compound complete all as specified and as directed.Make: FOSROC or equiavalent
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed.
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed.
M & L for Bitumen Flashing Aluminum Coated Water proofing Self Adhesive Sealing tape, 150 mm wide to seal the joint of leakage / sepage of roof complete all as specified and as directed
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, sheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, sheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point controlled by one, one way switch 06 Amps.
All as per srl item No 81 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 81 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 81 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 81 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Supply and fixing in repair modular switch, 6 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed. Make : Anchor/Havells/Legrand
Supply and fixing in repair modular bell push with indicator, 06 Amps, single pole, one way, 230 volts, complete all as specified & directed. Make : Anchor/Havells/Legrand
Supply and fixing in repair modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified & directed. Make : Anchor/Havells/Legrand
Supply and fixing in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed. Make : Anchor/Havells/Legrand
Supply and fixing in repair modular socket outlet flush type 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed. Make : Anchor/Havells/Legrand
Supply and fixing in repair ding dong bell, AC, 230 volts, single pole complete all as specified & directed. Make : SSK, or Havells or Anchor
Supply and fixing in repair ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed. Make: - Anchor/Havells/Legrand
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, sheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per srl item No 93 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 93 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 93 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 93 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in repair switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F in repair bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F in repair switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F in repair socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F in repair socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F ceiling fan regulator , stepped type of 0 to 04 rotary steps, electronic, 2 Module socket type, humfree, AC, 230 volts, 100 watts complete
Supply and fixing in repair ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified & directed. Make : SSK/Havells/Anchor
Supply and fixing in repair lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete all as specified & directed.
Supply and fixing in repair decorative wall mounting, fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K of B22 base cap, and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and Fixing in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down of exsting u/s tube light fitting and supply and fixing in repair on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in repair ultra modern recess/surface mounting 36 Watts, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
Taking down of exiting u/s security light fitting and supply and fixing energy saving LED security light fitting with lens of 45 watts Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GI tube bracket for mounting of light fitting, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Supply and fixing Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as above but 06 Sqmm nominal cross sectional area.
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Make: - Legrand/Havells/Hager/Schneider
Supply and fixing in repair sheet metal enclosure distribution board, double door, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed. Make :- Legrand/Havells/Hager/Schneider
Supply and fixing in repair sheet metal enclosure distribution board, double door single pole and neutral, AC, 230 volts, 12 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed. Make :- Legrand/Havells/Hager/Schneider
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- Make :-Legrand/Havells/Indoasian/Schneider (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. Make :- Legrand/Havells/Indoasian/Schneider (b) MCB, SP, AC, 240 volts of 40 Amps, "C" curve, 10 KA breaking capacity - 8 Nos. Make :- Legrand/Havells/Indoasian/Schneider
Supply and fixing in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :- Legrand/Havells/Hager/Schneider
Supply and fixing in repair MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :- Legrand/Havells/Hager/Schneider
Supply and fixing in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :- Legrand/Havells/Hager/Schneider
Supply & fixing in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. Make :- Legrand/Havells/Hager/Schneider
Supply & fixing in repair MCCB, 200 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. Make :- Legrand/Havells/Hager/Schneider
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost complete all as specified and directed.
S&F in replacement fan motor kit incl blade, steel body for desert cooler of flow capacity upto 4000 Cum/Hr complete all as directed (Make :- Khaitan/CG/Bajaj)
M&L fan blade (PVC type) suitable for desert cooler up to 450mm sweep fan complete all as directed (Make as per sample)
S&F in repair plastic submersible pump suitable for desert cooler any size complete all as directed (Make : Khaitan/CG/Bajaj
Supply and fixing 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler.
S&F desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size.
S&F in replacement desert coolers body of required size made out of 18 SWG MS sheet complete including inside panel made out of 22 SWG MS sheet complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed.
S&F in repair PVC flexible pipe of high density for 15 mm bore for desert cooler of any size complete
M&L for servicing of any type and any make of split type AC/Window AC of 2 ton/1.5 ton capacity complete by dismantaling of AC and re-fixing after cleaning and replacement defective parts, dismantling the cover of condensing unit carefully and carry out servicing cleaning of the external surface (both side) throughly with the help of descaling chemical, brush, plain water and dry properly by using air blower for cleaning air dust deposited on epqt and charging of gas in adequate quantity as required re-fixing after repair complete
Supply and charging of refrigerant gas R-134a/R-22 for any type and capacity of Window/Split AC and checking for leakage (if any) after charging of gas complete
S&F in replacement Motor double shaft 1/5 HP capacity for window type AC 1.5 ton/2 ton capacity complete (Make : As per sample)
S&F in replacement Motor single shaft 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample)
S&F in repair thermostat for split AC/Window AC of capacity 1.5/2 Ton complete (Make : As per sample)
S&F of filter for split AC of 1.5/2 TR cap including taking out the old u/s filter complete
S&F of Reverse valve (heating and cooling type) suitable for split AC of capacity 1.5 TR by taking out of old u/s valve from the outdoor unit of AC and fixing of new valve by breazing/soldering and charging of adequate quantity of gas and testing on completion complete all as directed
All as per above but for split AC of 2.0 TR capacity
S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5 TR and charging of adequate quantity of refrigerant gas and testing on completion complete (Make : Bule Star/Carrier/Kirloskar/Emarsion/Teckmesh)
S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5TR / 2.0 TR complete
Supply and fixing pressostato pressure switch druckschalter 230 volt 50 HZ 10-16 Amps 20-40 PSI F1/4 inch beloving type PM/5 suitable for pressure pump.
S&F or passing through pipe, 6 Sqmm, 2 core, 1100 Volts grade, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed service cable twin core flat or circular for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed service cable twin core flat or circular for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
S&F or passing through pipe, 16 Sqmm, 4 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
Supply, install, testing and commissioning in replacement of factory made tested LT panel board of size not less than 130 cm x160 cmx 65 cm cubical double door compartment indoor type wall mounted suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating not less than 1.5 times of incoming/ outgoing MCCBs/MCBs installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 2.0 mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm) and comprising of the following including necessary arrangement for fixing on wall comprising with followings:- INCOMING:- (i) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 1 Nos (ii) Voltmeter digital type - 01 No (iii) Ammeter digital type - 01 No (iv) CT ratio 250/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating lamp one set of three OUTGOINGS:- (A) 1st Compartment :- (i) MCB TPN, 100 Amps, 50 Hz, 415 Volts, 16 KA - 1 Nos (ii) MCB SP 32 Amps, Curve 'C', 10 KA-10 Nos (B) IInd Compartment :- (i) MCB TPN, 100 Amps, 50 Hz, 415 Volts, 16 KA - 1 Nos (ii) MCB SP 32 Amps, Curve 'C', 10 KA-10 Nos (C ) IIIrd Compartment:- Electronic engergy/ KWH meter, 3 phase 4 wire, 3x 240 Volts, 50 Hz, 10 amp to 60 amps rating, Accuracy class 1, temper proof - 01 No (Make: Secure Meter Ltd or equivalent as approved)
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs. 58636.00
ANSH VANSH CONSTRUCTION COMPANY
M/S AADI ENTERPRISES
A R construction
The new hut furnitures
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .