Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.0 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | ₹16.0 L | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹16.9 L+₹88,375 (5.53%)Rejected-Finance | ₹16.9 L+₹88,375 (5.53%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹18.7 L+₹2.7 L (16.7%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹18.7 L+₹2.7 L (16.7%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹19.0 L+₹3.0 L (18.7%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹19.0 L+₹3.0 L (18.7%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹19.2 L+₹3.2 L (19.8%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | ₹19.2 L+₹3.2 L (19.8%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
2 Jul 2022, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
MISC REPAIRS AND REWIRING OF INTERNAL ELECTRIFICATION SERVICES AS WELL AS ATTEND MAINTANANCE PROGRAMME IN NEW CANTT AREA OTM ACCN AT PATIALA MIL STN
2022_MES_521214_2
GE(N)/PAT-06/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹90,000
Yes
12 Aug 2022
11 Jun 2022
4 Jul 2022
11 Jun 2022
2 Jul 2022
18 Jun 2022
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of walls, ceiling etc all as specified and directed.
Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan and including new PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel cadmium plated terminal box not less than 1.6mm thick for mounting Modular type switches, sockets, fan regulators etc with modular top cover including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed complete all as specified and as directed. (Switches and regulators shall be measured and paid for separately.) Note II-( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- The cost of Modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item) Note-IV-Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. Note : (i) Contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by two 2 way switches and including new PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel cadmium plated terminal box not less than 1.6mm thick for mounting Modular type switches, sockets, fan regulators etc with modular top cover including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. ( Wiring shall be done as per colour code in IS for phase, neutral and earth). (Note:- Cost of Eye/bottle thimbles used for connections in switches,sockets,MCBs in DBs shall deemed to be included in the unit rate quoted for this item.
All as per item No. 02 herein before but 6 Amp socket point on same board but with other switches complete all as specified and directed.
All as per item No. 02 herein before but one 6 Amp socket point on independent board complete all as specified and directed.
All as per item No. 02 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board complete all as specified and directed.
Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item.
All as per Sl item No 7.00 above herein before but one light point controlled by 2 way complete all as specified and directed.
All as per Sl item No 7.00 above herein before but 6 Amp socket point on same board but with other switches complete all as specified and directed.
All as per Sl item No 7.00 above herein before but one 6 Amp socket point on independent board complete all as specified and directed.
All as per item No.7.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board complete all as specified and directed.
Supply and fix in replacement of Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed.
Supply and fix in replacement of Modular switch 2 way, 6 Amps, 1 module complete all as specified and directed.
Supply and fix in replacement of Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed.
Supply and fix in replacement of Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.and directed.
Supply and fix in Bell ding dong electronic complete all as specified and directed.
Supply and fix in replacement of Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed.
Supply and fix in replacement of Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed.
Supply and fix in replacement of Fan regulator modular type 2 module complete all as specified and directed.
Supply and fix in Ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed.
S&F blank plate wherever required complete all as specified & directed
Supply and fix in replacement of Lamp holder including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed.
Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
Supply and fix in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed.
Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed.. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
Supply and fix MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed.
Supply and fix MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed.
Supply and fix in replacement epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified and directed. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed.
Supply and fix MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Supply and fix MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Supply and fix MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement @ 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation including charcoal and common salt in alternative layers 15 cm Thick mixed refilling of soil etc complete all as specified and directed.
Supply & fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed.
Supply and fix in replacement of Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 10/12W 6500K of capacity ,watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed.
Supply and fix in replacement of metal flush box of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of metal flush box of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 3 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 4 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 6 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix in replacement of modular cover plate of 8 module in MAP qtrs located in NEW cantt complete all as specified and directed.
Supply and fix PVC air ventilation fan of sweep 200 mm RPM-1350 and having air delivery 500 cubic meter per hour of capacity 25 Watt complete all as specified and directed.
Supply and fix Modular switch 1 way, 6 Amps, 1 module, 230 volts make and fitment as per gound requirement complete all as specified.NOTE-contractor shall visit the site to check make and size of item complete all as specified and directed.
Supply and fix Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified and directed. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified and directed. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified and directed. NOTE-contractor shall visit the site to check make and size of item.
Supply and fix in replacement LED 15 Watt decorative wall light for MAP Qtr pocket-07 located in New Cantt complete all as specified and directed.
Supply and fix in Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver complete all as specified and directed.
Supply & fix Switch piano, flush type, 5 amps, 240 V single pole, one way complete all as specified and directed.
Supply & fix Switch piano, flush type, 15 amps, 240 V single pole, one way complete all as specified and directed.
Supply & fix Socket outlet, 3 pin , 5 amps multipuporse, piano flush type, complete all as specified and directed.
Supply & fix Socket outlet, 2 in 1, having provision of 3 pin 5 Amps & 3 pin 15 Amps complete all as specified and directed.
Supply & fix Fan regulator, electronic step type complete incl making necessary connections to make it functional complete all as specified and directed.
Supply & fix Bell push, flush type 5 Amp, 240 volt all as specified & directed.
m/s s.n. builders
UNITED ENGINEERING CORPORATION
Arneja Builders
u and v engineers and consultants
M/s Anil Kumar and co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .