Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹40.0 L+₹1.6 L (4.20%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹41.9 L+₹3.5 L (9.15%)Rejected-Finance | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹42.6 L+₹4.2 L (10.9%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹45.5 L+₹7.1 L (18.5%)Rejected-Finance MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | L5 | Rejected-Finance Highest amount quoted |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Jun 2020, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_347194_1
8249/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Garrison Engineer (East) Jabalpur
D a(ii)
9 documents required · 9 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹96,000
Yes
14 Aug 2020
23 May 2020
24 Jun 2020
23 May 2020
22 Jun 2020
8 Jun 2020
23 May 2020 - 6 Jun 2020
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25cm thick complete all as specified.
Removing excavated material n.exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for repair- of leakages GI pipe of size 20 mm by replacing the Tees, bends, sockets unions etc complete including all acessories with necessary exacavation and earth work; returning filling & removal for that job, all as specified and directed by Engineer-in-Cahrge.
All as per item srl no 4 here in before but size 25mm bore.
All as per item srl no 4 here in before but size 40mm bore.
All as per item srl no 4 here in before but size 50mm bore.
All as per item srl no 4 here in before but size 80mm bore.
Repairing of leakages of CI/DI pipes of size 80 mm by replacing the Tees, bends, sockets and providing the other materials required at site such as lead joint, to complete the job including excavation and other earth work returning filling and removal. Note :- CI/DI bends, sockets,Y juction,cross,collars,cap,lead joint/tighten joint and connected items will be measured and paid separately
All as per item srl no 9 here in before but size 100mm bore.
All as per item srl no 9 here in before but size 150mm bore.
All as per item srl no 9 here in before but size 200mm bore.
Material and labour for ISI marked CI/DI pipe fittings up to size 80 to 200 mm dia such as bends, Tapers tail pieces, Tee pieces , caps and plug set including rubber ring push on joints complete as specified and directed
Taking up and down existing 20mm GI pipe lines for replacement/ relaying /refixing at site complete all as specified and directed . Note : Excavation/Earthwork shall be measured and paid separately
All as per item srl no 14 here in before but size 25mm bore.
All as per item srl no 14 here in before but size 40mm bore.
All as per item srl no 14 here in before but size 50mm bore.
All as per item srl no 14 here in before but size 80mm bore.
S & F GI tubing , medium grade, galvanised, with all fittings, laid in trenches of size 20mm bore complete all as specified and directed.
All as per item srl no 19 here in before but size 25mm bore.
All as per item srl no 19 here in before but size 40mm bore.
All as per item srl no 19 here in before but size 50mm bore.
All as per item srl no 19 here in before but size 80mm bore.
Cleaning of retrieved 20mm bore GI pipe lines and laying in trences the same after cleaning internally (by cleaning brush) and externally (by scrapping and washing) including replacing GI fittings all as directed .
All as per item srl no 24 here in before but size 25mm bore.
All as per item srl no 24 here in before but size 40mm bore.
All as per item srl no 24 here in before but size 50mm bore.
All as per item srl no 24 here in before but size 80mm bore.
S&F in replacement of gun metal/globe or gate valves of 20mm dia with iron wheel head, ISI marked confirming to IS-780, screwed both ends for iron pipe and fixed complete all as specified
All as per item srl no 29 here in before but size 25mm bore.
All as per item srl no 29 here in before but size 40mm bore.
All as per item srl no 29 here in before but size 50mm bore.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1000 x 1000x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
All as per item srl no 33 here in before but size 900X900X900 mm.
All as per item srl no 33 here in before but size 600x600x900 mm.
All as per item srl no 33 here in before but size 1200x1200x1200 mm.
All as per item srl no 33 here in before but size 900x900x1200 mm.
Taking out existing 80 mm bore CI/DI pipe lines and stacking at site for disposal or reuse all as directed . Note : Excavation/Earthwork shall be measured and paid separately
All as per item srl no 38 here in before but size 100mm bore.
All as per item srl no 38 here in before but size 150mm bore.
All as per item srl no 38 here in before but size 200mm bore.
M&L for DI pipes K-7 size 80mm bore with spogot and socket ends all as directed .
All as per item srl no 42 here in before but size 100mm bore.
All as per item srl no 42 here in before but size 150mm bore.
All as per item srl no 42 here in before but size 200mm bore.
Supply and fix in replacement of CI sluice valve with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 80 mm bore with hand wheell confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm complete all as specified and directed. Make : Kirloskar/L&T/Upadhyay
All as per item srl no 46 here in before but size 100mm bore.
All as per item srl no 46 here in before but size 150mm bore.
All as per item srl no 46 here in before but size 200mm bore.
M&L run lead joint 80 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 100 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 150 mm dia complete all as specified and directed by engr-in - Charge.
M&L run lead joint 200 mm dia complete all as specified and directed by engr-in - Charge.
S&F in replacement Hydrant valve 63 mm dia, made out of gun metal heavy duty with female coupling outlet complete with blank cap chain as per IS-5290 and ISI mark complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay
S&F in replacement Hydrant valve lugs of gun metal for above type of valve complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay
S&F in replacement Hydrant valve wheel cost iron type complete all as specified and directed by engr-in - Charge. Make : Kirloskar/L&T/Upadhyay
S&F in replacement Hydrant cap with chain for hydrant valve 63mm dia complete all as specified and directed by engr-in - Charge.
S&F in replacement FLX/RRL canvas hose ( 15 m length ) with end fittings, male & female extra coted with outer special elastomeric coting circularly wove jacket manufactured by 100% high density synthetic yarn inset again milded anti rot lined with special compound synthetic rubber with bursting pressor of 40 Kg per cm sq bearing ISI mark under IS No. 636-1988 type 'A' binded with heavy duty male & female coupling.
S&F in replacement Hose box made of 18 gauge MS sheet 800mm x 600mm x250mm with double door with 4 mm thick glasses and door frame made of gauge MS sheet painted fire red outside and brilliant white inside depot with PCC foundation complete all as specified and directed by engr-in - Charge..
S&F in replacement spare parts kit for 3 pole power contractor 45Amps, 440 volts, with coil rating 230/440 volts type ML-3 Make : L&T/Legrand/Schnieder
S&F in replacement spare parts kit for 3 pole power contractor 70Amps, 440 volts, with coil rating 230/440 volts type ML-4 Make : L&T/Legrand/Schnieder
S&F in replacement 3 pole power contactor 110 Amps, 440 volts, with coil rating 230/440 volts type ML-6 Make : L&T/Legrand/Schnieder
S&F in replacement 3 pole power contactor 70Amps, 440 volts, with coil rating 230/440 volts type ML-4 Make : L&T/Legrand/Schnieder
S&F in replacement 3 pole power contractor 45Amps, 440 volts, with coil rating 230/440 volts type ML-3 Make : L&T/Legrand/Schnieder
S&F in replacement spare parts kit for 3 pole power contractor 110Amps, 440 volts, with coil rating 230/440 volts type ML-6 Make : L&T/Legrand/Schnieder
S&F in replacement Bimetalic Overload relays suitable for Power Contactor 40Amps, 440 volts, with coil rating 230/440 volts type ML-3 Make : L&T/Legrand/Schnieder
S&F in replacement Bimetalic Overload relays suitable for Power Contactor 70Amps, 440 volts, with coil rating 230/440 volts type ML-4 Make : L&T/Legrand/Schnieder
S&F in replacement Bimetalic Overload relays suitable for Power Contactor 110Amps, 440 volts, with coil rating 230/440 volts type ML-6 Make : L&T/Legrand/Schnieder
S&F in replacement Pressed leather gasket for CI for foot valve 200 mm, Make : Expart/existing make as approved by GE.
S&F in replacement Pressure gauge range 0 - 21 Kg cm Sqr, Make :H.Guru/existing make as approved by GE.
S&F in replacement Presser switch range 01 to 10 bar type RT-116, Code No. 17-5203, Make :Indofoss /existing make as approved by GE.
S&F in replacement Digital water leval indicator system 150 mm size digit direct display,operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. MAKE: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS
M&L for road cutting, including excavation returning filling in spreading leveling, well ramming in layers, swelling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling of existing road including a layer of premix, carpetting 25 mm thick using ready mix patch mate material, rolled & compacted for road patch repair work complete all as specified and directed.
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for round the clock of three shift of 08 hours each shift (for 24 hours daily including Sunday and holidays) for operation of pump sets, chloronome plant/BP Dozer for proper pumping from new map pump house near 4 tank to CMM (all OHTs ie , 1,00,000 GLN-1 NO, 20,000 -GLN 1 NO ,50,000 GLN-4 NOS) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Centrifugal pump sets 7.5 HP - 02 Nos , (ii) dosing plant - 01 No, (v) DG sets 30 KVA- 01No , (vi) control panel boards of centrifugal pump sets and operating delivery valve,distribution of water supply. Note : If quoted rate are less than min fare wages including GST the bid shall be treated as non bonafide and shall be rejected.
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for three shift of 8hrs (for 24 hrs daily including Sunday and holidays) for operation of pump sets, chloronome plant/BP Dozer for proper pumping in new map pump house near 506 ABW (all OHTs) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Centrifugal pump sets 7.5 HP - 02 Nos ,(ii) submersible pump sets 12.5 HP - 02 Nos , (ii) dosing plant - 01 No, (v) DG sets 50 KVA- 01No , (vi) control panel boards of centrifugal pump sets and operating delivery valve,distribution of water supply to complete area Note : If quoted rate are less than min fare wages including GST the bid shall be treated as non bonafide and shall be rejected.
Notes for item Nos – 74 & 75 as follows:- To maintain log sheet and log books for all installations and monthly duty roaster for duty staff.
POL chlorine gas or bleaching powder shall be arranged by the Engr-in-Charge as per requirement and issued to contractor under schedule B free of cost for bonafide Government use only & a pucca bound register shall be maintained showing day to day input/output only signed by JE/Engineer-in-charge/Contractor.
The unit per day means 24 hours. The contractor shall deployed one FGM per shift of 08 hours at installation viz 3 different FGM per day.
Pumping supply hrs shall be observed as mentioned in particular specification here in after or as directed.
One pumping set shall be work at a time.
Timing shall be decided by GE as per requirements.
It is the responsibility of the contractor that chlorine plant/BP dozer are to be operated at the time of supply of water.
The quoted rate shall be deemed to include for all surrounding premises cleaning such as in side the pump, outside, toilet including cutting of grass shrubs etc and always keep ready position whenever any visiting officer visits the site the pump houses should be cleaned and neat in all respect. In case any bad/adverse remark given by any visiting officer at any time the necessary recovery @ double the rate quoted per day shall be charged from the contractor as certified by Engineer-in-Charge and no claim whatsoever is admissible on the account, GE’s decision is final and binding on this account.
Testing water for residual chlorine and PH value and maintain directed level as directed and proper register to be maintained.
Gland packing, greasing and oiling of centrifugal pump sets shall be done monthly and proper register shall be maintained duly signed by the contractor, Engr-in-Charge & JE.
Trades men should be wear always Operators uniform and take preventive /safety measures and will use protective clothing as per code of IE rules safety code. Department will not responsible for any type of incident.
Contractor shall be made security pass for all operators and maintain proper register duly signed by all concerned.
T&P like spanners, screw drivers, pipe wrench, torch light, other items required for repair etc. will be provided by the contractor.
It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duly signed kept on record and payment of trade men for the Nos of days present will only be made, Engineer-in-Charge will be responsible for payment of trade men in his presence. Contractor shall provide proper dress to tradesmen as approved by Eng-in-Charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues.
In case the contractor does not operate the pumping set for a day or part thereof due to any reason whatsoever double of the quoted rate to each day will be recovered.
Leave of deployed person in inescapable cases shall be allowed on prior intimation but Contractor on demand of Engineer-in-Charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.
In no case wages of deployed persons shall be less than the Minimum wages fixed by Govt Competent Authority. It is mandatory requirement for Contractor that payment of deployed person shall be made through Cheque/RTGS/Acceptable Electronic Mode only. Proof of payment shall be submitted by Contractor to Engineer in Charge monthaly basis or during claiming on account of Advance (RAR)/FB.
The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952. shall be strictly adhered to by the Contractor. Social Security to workers i.e. EPF, ESIC, Personal Insurance(if applicable) on part of Employer shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
Statuatory levies/GST if applicable on part of contracts shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting Officer for their attendence & obtain instructions. An attendence register shall be maintained by Contractor on site shall be certified by MES rep every day.
T&P - Working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by Contractor at his own cost.
Retrieved materials obtained from replacement by new items shall be deposited in MES store.
An uniform of blue shirt/jersy duly embossed "MES OUTSOURCING SERVICES" at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.
Documentation - Attendance register & wages register,Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost.
S&F in repairs GI long socket suitable for 100 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 80 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 50 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 40 mm dia and 100 mm long
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading including taking down as per sample & directed by engr-in- charge
250 mm bore sluice valve
200 mm bore sluice valve
150 mm bore sluice valve
100 mm bore sluice valve
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Taking down unservicable existing motor starter of any size/capacity
M&L Fully Automatic Star Delta Motor starter 50 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 35 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 22-32 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 25 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-21 complete all as specified. (Make : L&T cat no SS 91855 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
Taking down unservicable existing cable from motor/pannel to starter any size/capacity
S & F PVC Insulated unsheathed cable 19/1.54 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
S & F PVC Insulated unsheathed cable 37/1.56 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
S & F PVC Insulated unsheathed cable 37/2.04 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
Dismantling/taking out unserviceable air release valve/non return/foot valve of any size by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix CI double end flanged and drilled non return valve of size 200 mm PN-1.6 dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 150 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. MAKE : Kirloskar/Upadhyay/L&T
S&F in repairs MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make :Legrand/ L&T / /Hager
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make :Legrand/ L&T / /Hager
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 63 A 16 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
Cutting and threading of existing GI pipe 100 mm dia
Cutting and threading of existing GI pipe 80 mm dia
Cutting and threading of existing GI pipe 50 mm dia
Cutting and threading of existing GI pipe 40 mm dia
Taking down of MCCB of any size
Note :- Schedule of Credit amounting to Rs.2,56,015.00 to be deducted during AOC
Electromech Engineers
KRD ASSOCIATE
Goodluck Enterprises
ASHOKA ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .