Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC HAPPY HOME FRIENDS COLONY RAMGARH CANTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | JHARKHAND | 829122 | ₹6.2 Cr | L1 | Accepted-AOC Being overall reasonable |
| 2 | L2₹7.0 Cr+₹76.7 L (12.3%)Rejected-Finance | ₹7.0 Cr+₹76.7 L (12.3%) | L2 | Rejected-Finance Other than L1 |
Tender Value
₹6.4 Cr
EMD Value
₹6.5 L
Closing Date
1 Jun 2024, 6:00 pmClosed
CEJZ JABALPUR
HQ CEJZ JABALPUR
PROVISION OF OTM ACCN FOR OFFICE COMPLEX OF HQ J AND B SUB AREA AT DANAPUR
2024_MES_643940_1
752923A
Open Tender
Civil Works
Lump-sum
730 days
DANAPUR
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE DANAPUR
₹6.5 L
Yes
2 Jul 2024
1 Mar 2024
4 Jun 2024
1 Mar 2024
1 Jun 2024
13 May 2024
Amount
SCHEDULE "A"
SCHEDULE "A" PART-I (Building Work) Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES.
Sch 'A' Part-II (Internal Water supply) Lump sum price worked out by the contractor for Internal Water supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Sch 'A' Part-III (Internal Electric Supply) Lump sum price worked out by the contractor for 'Internal Electric Supply' as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-IV (External Water supply) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Sch 'A' Part-V (External Electrification ) Lump sum price worked out by the contractor for'External Electrification lightening' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Road, Path and Culvert) Lump sum price worked out by the contractor for 'Road Path and Hard standing' as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Sewage Disposal) Lump sum price worked out by the contractor for 'Sewage Disposal ' as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
Sch 'A' Part-VIII (Area Drainage) Lump sum price worked out by the contractor for 'Area Drainage ' as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
Sch 'A' Part-IX (Demolition) Lump sum price worked out by the contractor for Demolition) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES.
Sch 'A' Part-X (Fencing/ Gate/ Compund Wall) Lump sum price worked out by the contractor for 'Fencing and Gate / Compound Wall' as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Sch 'A' Part-XI (Fire Fighting) Lump sum price worked out by the contractor for 'Site clearance, excavation & earth works' as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
Sch 'A' Part-XII (Site clearance, excavation & earth works) Lump sum price worked out by the contractor for 'Site clearance, excavation & earth works' as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
Note for Srl No 2 to 13 The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 16 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule
Schedule 'A' Part-XIII (Miscellaneous works)
Item No 01 : M&L for Heavy duty precast Machine pressed precast conctete interlocking paver block ruberized moulded any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade fixed with gray cement and pigment complete all as spd and directed.
Item No 02 : M&L for Heavy duty precast Machine pressed precast conctete interlocking paver block ruberized moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade fixed with gray cement and pigment complete all as spd and directed.
Item No 03 : Provn of hume pipe culvert with & using Hume pipe 450 dia class NP-3 and 6 mtr long laid over concrete bed and Job jointed with copping & rendering complete all as specified and directed.
Demolition
Item No 04 : Taking down copper/aluminium point wiring material complete all as specified and directed.
Item No 05 : Taking down sub main wiring 2.5/4.0/6.0 Sqmm size including DBs, MCBs etc removing materials to store for store for keepingin safe custody or for taking credit complete all as specified and directed.
Item No 06 : Taking down bldg security light any capacity including all fittings and to store for keeping in afe custody or for taking credit complete all as specified and directed.
Item No 07 : Taking down indoor feeder piller pannel any size including all fittings and to store for keeping in safe custody or for reuse and fix in other location complete all as specified and directed.
Item No 08 : Taking out old unserviceable LT cables of cross sectional area any size including excavation, returning filling, pipes bricks or pre-cast concrete cable cover etc of any description from trenches / walls / poles by disconnecting the cable from pole / feeder / panel board etc. and keep serviceable bricks or pre-cast concrete cover, cable, pipe etc. to store for keeping in safe custody or for taking credit complete all as specified and directed.
Item No 09 : Taking up or down 25 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Item No 10 : Taking down C/Fan, E/Fan, Wall mounted fan, Gyser any size including connecting materials complete all as specified and directed. Note: removing materials shall be handover to MES store for future disposal action.
Water Cooler
Item No 11 : Supply and fixing self contained drinking water cooler partially stainless steel working with non CFC refrigerent of above 3 star rating suitable for operation on 230 Volts 50 cycles AC supply having approx storage and nominal cooling capacity 40/80 Ltrs incl connecting the items complete with and including making of PCC platfarm of suitable size for fixing of water cooler complete all as specified and directed.
Item No 12 : Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 150 volts to 280 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and current carrying capacity 6 Amps suitable for above water cooler complete all as specified and directed
Desert Cooler
Item No 13 : Supply and fixing heavy duty desert cooler min Air delivery/capacity 500 cum/hr, with steel body with sheet thickness for filter, panel grill, top of cooler body, cabinet not less than 0.8mm and for sump tank not less than 1 mm with iron stand as recommended by manufacturer for fitting at window, all internal surface of steel body cooler painted with water resistant paint of suitable fan size and fan motor, directional front grill of suitable size having air throw min 80 feet, submersible pump, anti bacterial technology pads, bottom water tank capacity not less than 80 litres complete all as specified and directed. Note: 1. Contractor shall provide warranty of 02 years for product & pump and is liable for defect rectification during this period. 2. TD shall be followed for cooler stand.
Refrigeration
Item No 14 : Supply and Installation, commissioning of Refrigerator electric driven single phase having capacity 224 Ltrs (or nearest higher standard size) frost free working with non CFC refrigirent and above 5 star rating.
Item No 15 : Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 1.0 KVA suitable for Refrigerator complete all as specified and directed.
Fire Fighting
Item No 16 : Supply and installtion of OH water storage tank GRP of capcity 20,000 ltrs including all fittings complete all as specified and as directed.
Item No 17 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138 complete all as specified and as directed.
Item No 18 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B complete all as specified and as directed.
Item No 19 : S&F for fixing fire extinguisher water stored pressure type class A, ISI marked of capacity 9.0 Litres conforming to IS:15683:2006 complete all as specified and as directed.
Item No 20 : S&F for stored pressure type, ISI marked Fire extinguisher ABC type dry powder of capacity 9.0 Kg conforming to IS: 15683:2006 mde from seamless cylinder fitted with ISI marked controlled valve, high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket complete all as specified and as directed.
Item No 21 : Supply and fixing for Fire buckets (Dry sand tored type) conforming to IS: 2546:2006 complete all as specified and as directed.
Air Conditioning
Item No 22 : Supply and fix air all weather type split unit air conditioner electric driven single phase indoor/outdoor units complete with cordless remote control unit and with in built air ioniser and Plasma filter, anti dust, antimicrobial protection, anti-corrosive coating, LED Display, self diagnosis, sleep mode, turbo, adjustable cooling for better indoor air quality with 5 star rating invertor type and ISEER 5 air conditioner of capacity of 2 TR, rated complete all as specified and directed.
Item No 23 : Supply and fix air all weather type split unit air conditioner lectric driven, single phase indoor/outdoor units complete with cordless remote control unit and with in built air inoiser and Plasma filter, anti dust, antimicrobial protection, anti-corrosive coating, LED Display, self diagnosis, sleep mode, turbo, adjustable cooling for better indoor air quality with 5 star rating invertor type and ISEER 5 air conditioner of capacity of 1.5 TR, rated complete all as specified and directed.
Item No 24 : Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 160 volts to 270 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and current carrying capacity 15 Amps suitable for above 2 TR split air conditioner.
Item No 25 : Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 150 volts to 275 volts with out put voltage stablized at 230 volts with accuracy of +- 2.5% and current carrying capacity 12 Amps suitable for 1.5 TR split air conditioner.
DG Set
Item No 26 : Supply and installation of silent Diesel Engine driven generating set of capacity 40 KVA, 415 volts, 3 phase 4 wire,50 Hz engine as per ISO: 3046,BS5514 and Alternator as per IS: 4722/BS5000 at power factor 0.8, noise level below 75dB,fuel tank capacity at least minimum 8 hours running time, overall dimensions 2500 X 1100 X 1380 of systems, battery 180 AH, 12 Volt including suitable battery charger complete with as specification For Engine -4 nos. of cylinder, 1500 RPM rated speed, For Alternator- insulation class-H, IP-23 protection, rated current 175.6 amps, voltage regulation (+/-) 1%, overload capacity 10% for one hour, for every 12 hours running and with foundation (as per OEM design) with relay panel and switch gears for automatic starting on main failure, control panel (AMF Panels), having meter and sound proof canopy as per CPCB norms complete all as specified.
Item No 27 : M & L for Earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth GI strip of size 32 X 6 mm by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI Strip protected by GI pipe 40mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete. (for LT Panels ) Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
External Water Supply
Item No 28 : M & L for Construction of brick masonry valves pits of size 900mm x 900mm x 900mm (internal dimension) with brick masonary built in cement mortar 1:4 including 15 mm thick plastering in CM (1:4) internal and extenal surface of chamber including angle iron frame with MS shet cover 3.15 mm thick and locking arrangement including applying two coats of synthetic enamel paint over a coat of primer including all necessary excavation and earth work PCC work 1:4:8 type D2 foundation concrete 100 mm thick complete all as specified and as directed.
External Electrical Supply
Item No 29 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of following sizes complete all as specified and directed.
(a) 185 sqmm 3½ core .
(b) 120 sqmm 3½ core.
( c ) 35 sqmm 3½ core.
(d ) 16 sqmm 4 core.
( e) 10 sqmm 2 core.
Item No 30 : Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with toughened glass and individual high power LED with secondary optics of capacity 70/75 Watt 240 volts AC 50 Hz , IP 66 protection including electrical connection and five years on site warranty from manufacturer complete all as specified and directed.
Item No 31: Supply and fix FRP street Light Pole Box, Size - 300 x 200 x 125 mm,with DIN Rail for MCB including all fittings complete all as specified and as directed.
Item No 32 : Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp completeall as specified and as directed.
Item No 33 : S & F Integral decorative LED bollard with polycarbonate diffuser with IP 65 protection suitable for 9/10 watts LED bulb with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, elecrical connections with adequate size complete as all specified and as directed.
Item No 34 : M&L for wiring with two runs of 1.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to pole including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point all as specified and directed. (Note :-(i) One run of PVC rigid conduit with all fittings/accessories and Two runs of 1.5 sqmm single core cable and one run of 1.5 sqmm earth continuity wire to be measured as one length).
Item No 35 : Supply, installation, commissioning and testing Outdoor LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to MCCB input and MCCB output of suitable capacity, made out of 3.15 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :-
INCOMMING
(a) Copper strip busbar of current carrying capacity 400 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 315 Amps, adjustable thermal magnetic type, thermal release range (64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(c) Supply and fixing changeover switch C-line type ,125 amps open execution type ,415 volt,50 cycles complete with operation handle.
(d) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three).
OUTGOING
(a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 250 Amps, adjustable thermal magnetic setting type with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 100 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(c) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Item No 36 : Supply, installation, commissioning and testing indoor LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to MCCB input and MCCB output of suitable capacity, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :-
INCOMMING
(a) Copper strip busbar of current carrying capacity 400 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 250 Amps, adjustable thermal magnetic type, thermal release range (64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(c) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three).
OUTGOING
(a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 125 Amps, adjustable thermal magnetic setting type with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos.
(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 100 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos.
(c) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Item No. 37: Supply, installation, commissioning and testing indoor LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to MCCB input and MCCB output of suitable capacity, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :-
INCOMMING
(a) Copper strip busbar of current carrying capacity 200 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic type, thermal release range (64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.
(c) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three).
OUTGOING
(a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos.
(b) MCB TPN, c-curve of 40 Amps including all fixing accessories complete all as specified. -02 Nos.
(c) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Item No. 38: Supply ,fabrication, installation and testing of LT out door type factory made 1000mm X 700mm X 500mm size CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.
Outgoing
(a) MCB Single Pole and neutral of 5 to 32 Amps,240 volts, 10 KA breaking capacity C curve - 03 Nos.
(b) TPN MCB four Pole 16 to 32 Amps,240 volts, 10 KA breaking capacity C curve - 01 Nos.
(c) Analog type time Switch, three moduled, 240 volts AC- 01 No.
(d) Power contractor 32 amps 3 Pole 415 Volts AC - 01 No.
(e) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Internal Electrification
Item No 39 : M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chases and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One light point controlled by one, two way switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(f) One bell point controlled by one, bell switch 5 Amps
Item No 40 : Description all as per item No 39 here in before but using 2.5 sq mm single core two nos copper conductor cables of FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Item No 41 : Description all as per item No. 39 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC point)
Item No 42 : M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 16 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 16 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 16 sqmm cable, one runs of 16 sqmm cable and one run of PVC conduit will be measured as one unit
Item No 43 : M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable, one runs of 10 sqmm cable and one run of PVC conduit will be measured as one unit
Item No 44 : M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
Item No 45 : S & F for sheet metal enclosure MCB DB TPN 4 way Horizontal type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Item No 46 : S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Item No 47 : S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
Item No 48 : S & F for MCB four pole rated capacity 100 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 49 : S & F for MCB DP rated capacity 40-63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. ( 63A-6 Nos, 40A-19 Nos)
Item No 50 : S & F for MCB Single pole rated capacity 40-63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 51 : S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No 52 : S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
Item No 53 : S & F modular type TV Socket out let complete all as specified and as directed.
Item No 54 : S & F modular type LAN Socket RJ 45 with complete box complete all as specified and as directed.
Item No 55 : S & F modular type Telephone socket RJ 11/12 with complete box complete all as specified and as directed.
Item No 56: S & F modular Metal flush box 8 module complete all as specified and as directed.
Item No 57 : S & F modular Metal flush box 12 module complete all as specified and as directed.
Item No 58 : S & F modular white cover plate with frame 12 module complete all as specified and as directed.
Item No 59 : S & F Engage light Decorative wall mounted luminaire made out of polycarbonate with unbreakable 02 Nos globe with suitable for LED bulb and provosion of 02 LED bulb 10 watts of colour RED and GREEN complete all as specified and as directed.
Item No 60 : S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed.
Item No 61 : S & F for LED 10 watts batten aluminium extruded with decorative end caps luminous efficacy not less than 120 lumen/watt complete all as specified and directed by Engineer in charge
Item No 62 : S & F surface/recess mounted ceiling light of capacity 36 watt, approx size of 2x2 ft , 230 volts with CRCA housing luminous efficacy not less than 120 lumen/W with and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed.
Item No 63 : S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/W 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
Item No 64 : S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts, luminous efficacy not less than 110 lumen/W with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
Item No 65 : S & F occupancy sensor suspended type to detect the presence of a person for inlude automatic adjustment of lights system in response to the quantity of people present for switch off/on the light in a circuit as per user requirement (for use at parking area, verandah or any other space where power saving is required.
Item No 66 : M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length 15mm GI pipe heavy grade for protection of GI wire and 20mm GI pipe heavy grade for watering with wiremesh and funnel including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified.
Item No 67 : Blank
Item No 67A : S&F 20mm dia PVC pipe with bends etc for drain out the water from AC including saddle with necessary fixing arrangement on outside the wall, tees, bends complete upto the ground level drain complete all as specified and directed.
Arboriculture
Item No 69 : Supply of best quality loose (Sweet earth) for plantation complete as per gardening practice and complete all as specified and as directed.
Item No 70 : Supply of approved Manure (Cow Dung) complete as per gardening practice and complete all as specified and as directed.
Item No 71 : Supply of Vermi compost of best quality complete as per gardening practice and complete all as specified and as directed.
Item No 72 : Supply and plantation of crotons and hedges, including preparation of ground to required depth and filling of good earth, cow dung and watering etc complete all as specified and as directed.
Item No 73 : Supply and plantation of Ashoka plants height of plant not less than 45cm above ground level including preparation of ground upto 60cm deep and filling of good earth, cow dung, vermi compost and watering etc complete all as specified and as directed.
Item No 74 : Supply and plantation of palm tress including preparation of ground upto 30cm deep and filling of good earth, cow dung, vermi compost and watering etc complete all as specified and as directed.
Furniture
Item No 75 : Almirah Steel Medium as per FD-1032
Item No 76 : Chair Visitor steel with arms as per FD/E6/MAP/12
Item No 77 : Confrence Table U type (Seventeen Seating Capacity) TP Make: Methodex/Godrej/Durian/Zuari
Item No 78 : Chair Revolving as per FD/E6/MAP/01
Item No 79 : Book Case Steel with glass panel as per FD-1028
Item No 80 : Revolving Magazine Stand TP Make: LF15 : Methodex/Godrej/Durian/Zuari
Item No 81 : Chair School with hand board as per FD/E6/MAP/05
Item No 82 : Table 1200mm x 900 x 760 mm as per FD/MAP-II/03
Item No 83 : Chair Dining as per FD/MAP-II/04
Item No 84 : Compactor set of six TP Make: Methodex MS1 6MC/Godrej/Durian/Zuari
SCHEDULE "A" (Schedule of credit) Schedule of Credit Rs 828142.40 (Minus) inserted by the MES. (Note : Credit amount shall be deducted manually to arrive net bid amount)
MS SHRI B.C. DAS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .