| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYAN PURI EAST DELHI DELHI 110091 UDYAM DL 02 0083384 | EAST DELHI | DELHI | 110091 | ₹19.3 L Quoted ₹20.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹20.8 LRejected-Finance | ₹20.8 L | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 3 | L3₹22.1 LRejected-Finance | ₹22.1 L | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 4 | L4₹24.1 LRejected-Finance | ₹24.1 L | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 5 | L5₹26.9 LRejected-Finance | ₹26.9 L | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L1 | M/S M.S.ENTERPRISES L2 | ARORA BROTHERS L4 | S B ENTERPRISES L5 | NEW TECH ELCTRICALS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT under ground cable / pole fondation and getting out including forming bottom surface to required level or slope, complete all as specified and directed. | 400 | Cum | 100 ₹40,000 | 100 ₹40,000 | 92 ₹36,800 | 100 ₹40,000 | 95 ₹38,000 |
| 2.00 | Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed. | 230 | Cum | 40 ₹9,200 | 30 ₹6,900 | 30 ₹6,900 | 30 ₹6,900 | 20 ₹4,600 |
| 3.00 | Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed. | 170 | Cum | 40 ₹6,800 | 40 ₹6,800 | 30 ₹5,100 | 40 ₹6,800 | 20 ₹3,400 |
| 4.00 | M&L for cutting of road depth up to 1.5 mtr below the normal ground level of suitable size to lay pipe upto 150 mm dia pipe across the road in horizontal position incl making good all disturbed surfaces of road to match with existing surfaces by premix road material/PCC complete all as specified and directed. | 20 | RM | 200 ₹4,000 | 300 ₹6,000 | 80 ₹1,600 | 100 ₹2,000 | 250 ₹5,000 |
| 5.00 | M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid. | 130 | Cum | 350 ₹45,500 | 300 ₹39,000 | 500 ₹65,000 | 400 ₹52,000 | 375 ₹48,750 |
| 6.00 | M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed. | 8 | Per 1000 Nos | 4,500 ₹36,000 | 3,000 ₹24,000 | 4,000 ₹32,000 | 5,000 ₹40,000 | 3,250 ₹26,000 |
| 7.00 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as speified and directed. Make: Mehtab tiles Indore/Hind Mosaic Tiles Upleta. Note: Purchase voucher and manufacturer test certificate shall be submitted by contractor while claiming payment.. | 75 | Each | 24 ₹1,800 | 300 ₹22,500 | 40 ₹3,000 | 25 ₹1,875 | 28 ₹2,100 |
| 8.00Supply & laying in replacement in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of following size suitable for earthed system including testing and commissioning complete all as specified 1100 volts/grade and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. Make of cable:- Gloster/ Polycab/ Incab/ Universal/ CCI/Havells | ||||||||
| 9.00 | All as per item No 8 above but Size of 150 sqmm 3.5 core complete all as specified and directed. | 150 | RM | 700 ₹1.1 L | 719 ₹1.1 L | 750 ₹1.1 L | 860 ₹1.3 L | 754 ₹1.1 L |
| 10.00 | All as per item No 8 above but Size of 120 sqmm 3.5 core complete all as specified and directed. | 180 | RM | 400 ₹72,000 | 607 ₹1.1 L | 630 ₹1.1 L | 720 ₹1.3 L | 636 ₹1.1 L |
Updated dates
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Jan 2026, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF HT/LT DISTRIBUTION, PERIMETER AND SECURITY LIGHTS, FLOOD LIGHTS, LT PANELS AND CERTAIN WKS FOR DGQA AND ASC SUPPLY DEPOT UNDER GE (I) KANPUR
2025_MES_744307_1
GE(I)/KAN/T-92 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹60,000
Yes
22 May 2026
12 Dec 2025
16 Jan 2026
12 Dec 2025
9 Jan 2026
26 Dec 2025
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT under ground cable / pole fondation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed.
Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.
Supply & laying in replacement in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of following size suitable for earthed system including testing and commissioning complete all as specified 1100 volts/grade and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. Make of cable:- Gloster/ Polycab/ Incab/ Universal/ CCI/Havells
All as per item No 8 above but Size of 150 sqmm 3.5 core complete all as specified and directed.
All as per item No 8 above but Size of 120 sqmm 3.5 core complete all as specified and directed.
All as per item No 8 above but Size of 95 sqmm 3.5 core complete all as specified and directed.
All as per item No 8 above but Size of 70 sqmm 3.5 core complete all as specified and directed.
All as per item No 8 above but LT cable 50 x 3.5 core complete all as specified and directed.
All as per item No 8 above but LT cable 35 x 3.5 core complete all as specified and directed.
All as per item No 8 above but LT cable 16 x4.0 core complete all as specified and directed.
Supply, laying in trenches or passing through pipe/ducts, XLPE insulated screened PVC sheathed galvanized steel strip armoured electric power cable with alumn conductor of size 185 sqmm 3 core suitable for earthed system including testing and commissioning complete all as specified and directed. Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.
Filteration and dehydration of Transformer oil for 11 / 6.6 / 0.433 KV transformers, 11 KV OCB's / PT's with stream line mobile filteration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : Filteration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescriped manner.
Supply, filteration and topping up Insulating Oil / pure hydrocarbon mineral oil, clean and sufficiently free from moisture and of other foreign matter of breakdown value - 60 KV or over at standard gap after filteration for Transformers & Switchgears and shall be as per ISS-335-1993 (fourth revision) incorporating up to date amendment and additional characteristics as indicated below: - (a) Oxidation stability (i) Neutralization oxidation value max 0.4 mg. KOH/gm (ii) Total sludge after oxidation max 0.10% by weight (b) Break down value 60 KV or more at standard gap (c) SK value upto 8% Make APAR (POWER OIL) / CASTROL Note :- (i) Test report from manufacture to be provided. (ii) Record of new insulating oil used for replacement and topping up oil in transformer shall be maintained duly signed by rep of contractor and AGE E/M.
Earth continuity conductor or main earthing lead 25 x 4 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required in repair complete all as specified and directed.
S&F in replacement of fully retroreflective sign boards of cut to sizes/shape having writing back ground made out of 18 SWG MS Sheet duly painted with two coats of synthetic enamel paint over and including a coat of primer including marking/writing letters, road sign any type with radium tape in different colours, duly mounted on angle iron frame 45mm X 45mm and 5mm thick fixed with nut, bolt, washer and welding (height as per site requirement) etc and painting with two coats of black synthetic enamel paint over and including a coat primer including all necessary earth work and PCC for foundation complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderdocumentsT92.pdf
Tender Documents • 0.99 MB
BOQ_833433.xls
BOQ • 0.74 MB
Download all tender documents and submit your bid