Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹15.9 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹16.0 LRejected-Finance | ₹16.0 L | L2 | Rejected-Finance other than lowest bidder |
| 3 | L3₹16.4 LRejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹16.4 L | L3 | Rejected-Finance other than lowest bidder |
| 4 | L4₹17.8 LRejected-Finance 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR NAGPUR MAHARASHTRA 440036 UDYAM MH 20 0031710 | NAGPUR | MAHARASHTRA | 440036 | ₹17.8 L | L4 | Rejected-Finance other than lowest bidder |
| 5 | L5₹20.0 LRejected-Finance 6 U 34 JAWAHAR NAGAR SRI GANGANAGAR SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | ₹20.0 L | L5 | Rejected-Finance other than lowest bidder |
| Sl No | Description | Qty | Unit | RAJENDER ENTERPRISES L2 | M/s Rohit Construction Co. L1 | Ankit Jindal And Company L5 | BIDAWAT ENTERPRISES L3 | GLOBAL POWER SYSTEMS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed. | 50 | RM | 486 ₹24,300 | 600 ₹30,000 | 450 ₹22,500 | 475 ₹23,750 | 800 ₹40,000 |
| 2.00 | Supply, install, test and commissioning of 82.5KVA/66 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty operation, with STD control panel , consisting of AMF feature to be errected at location indicated, all mounted in acoustic enclosure and Control panel as per manufacturers design and specification confirming to norms of CPCB IV+ and latest CPCB amendments complete with the following:-
i) DG Fuel tank of minimum capacity for 12 Hr runing in with fuel gauge etc complete all as ,
ii) Battery & Leads
iii) Silencer as per OEM design & recommendations complete as per latest CPCB norms.
iv) AVM Pads
v) First Fill of Lube
vi) Acoustic Enclosure
vii)Standard Control Panel (AMF) with connected switchgear/relays/meters complete to be errected at location indicated. (viii) Suitable size RCC cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations.
(ix)The cost of foundation bed incl earth work etc wiil be paid separately.
(x) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted. | 1 | Each | 13,84,200 ₹13.8 L | 13,90,000 ₹13.9 L | 17,50,000 ₹17.5 L | 14,05,000 ₹14.1 L | 14,80,000 ₹14.8 L |
| 2.01xi) The details specifications appended below :- (I) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, with 50°C intake air temperature, latest CPCB Euro emission engine ,turbocharged four stroke engine developing minimum 104 BHP @ 1500 RPM under NTP conditions, coupled to alternator mounted on Channel Iron base frame complete accessories etc .The prime mover provided should be as per IS specifications. (b) Air intake system should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.. (c ) Exhaust System should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. d) Fuel System should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be provided externally/separately. (e) Cooling System should comprise of radiator designed, hospital type silencer and tested for 50°C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. | ||||||||
| 2.02(f) Lubricating System should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free battery of capacity 12 V DC - 02 Nos with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator. (h) AC Generator The generator shall be horizontal and foot mounted,minimum82.5 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for voltage regulation + 1% , an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details:- (i) Type, Brush less AC Generators with PMG and space heater as per OEM design (ii) Output rating 82.5 KVA (iii) Output Voltage: 415 ± 1% under all loading conditions and with maximum voltage Dip at full load 0.8 PF shall be < 19% as per OEM design. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. (vii) Enclosure : Minimum IP-23 / Drip proof and screen protected. | ||||||||
| 2.03(viii) Electronic Automatic voltage regulator with response time < 75 m sec and + range of voltage adjustment. (ix) Class of insulation-'H' (x) Short circuit withstand 3 times rated current for 3 secs and overload withstand capacity for continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running (xi) Overspeed capacity 1800 RPM for 2 min. (xii)Suitable for Maximum Unbalanced Load across phases shall be less than or equal to 25%. NOTE : Following shall be deemed to be included in quoted rates :- (i) Standard Control panel with AMF feature outdoor type for 82.5 KVA DG set as per OEM design to be errected inside sub-station. (ii) Suitable size frame base with height as required mount the generator as per manufacturer's instructions/ recommendations. (iii) Connecting cables, from existing panels and connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories. (iv) Install & connecting fuel lines, cable etc. (v) Test and commissioning complete. (vi) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted. (j) BASE FRAME: Shall be stand by and fabricated with CRCA sheet metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads. | ||||||||
| 2.04k) ENGINE CONTROL PANEL: Control panel shall be powder coated , weather proof type with PCC3.3 controller or suitable equivalent controller as per OEM design, mounted inside the acoustic,consist of the following. 1.suitable rated switchgear/MCCB 2. Engine control unit (ECU),3. Current Trasformer set, 4. Indicating Lamps, 5. Set running & load on set Shall be indoor type manufactured with 14/16 guage CRCA sheet and is powder coated for weather-proff and long lasting finish consisting of alarm,indication and safety ( Over speed,High coolant temperature,low oil pressure,water in fuel,engine common fault low fuel level,low coolant level,emergency stop on enclosure, under frequency,over frequency,under voltage over voltage,over current,over load kw, battery under voltage), microprocessor power command controller, Aluminium busbars with suitable capacity with incoming/outgoing terminals, indicating lamps for 'Load ON' and 'Set Running', instrument fuses duly wired and ferruled , Volt meter, ammeter with selector switches, Frequency meter, energy meter, CTs and 3 Phase indicating lamps, timers etc all as per latest engineering practices.etc. complete all as specified and directed. | ||||||||
| 2.05(l) Standard Control panel with AMF feature ,door, slopy canopy type for 82.5 KVA DG set as per OEM design to be errected outside as indicated/directed. Standard Control panel with auto mains failure (AMF) feature complete , floor mounted type, vertical, factory made outdoor type, double door , canopy, fabricated out of 3.00 mm thick CRCA sheet with angle iron base frame made of 50 x 50 x 6mm or channels at base of Panel board floor mounted, dust and vermine proof, suitable for voltage 415 V Three Phase 4 wire, 50 HZ AC supply, weather proof, with separate hinge door for each compartment & locking arrangement, with back door openable (Screwed), legs welded/bolting complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN) of suitable rating, suitable double compression copper cable glands and including provn of the following :- (i) Protection relays as per OEM design/approved make. (ii) Minimum 160 A ,4P 36 KA EDO type MCCB of qty/capacity all as per OEM design (iii) Suitable rated resin cast CTs. (iv) Suitable rated inbuilt AVR. (v) SMPS based automatic battery charger, 24V, 20A with DCV, DCA -02 Nos. (vi) Digital Multifunction meters with RS 485 with LAN port hub. (xi) Suitable capacity copper control cables, necessary indications, hooters, auxilliary contactors, TNC & LVM interlocking etc. (vii) Provn of scope for future expansion for additioning of 1 No DG set from side end extension. (b) BACK-UP PROTECTION :- HRC Fuse for short circuit protection. (c) MICRO PROCESSOR BASED AMF MODULE :- | ||||||||
| 2.06(i) Functions:- aa) Manual/auto/test selector switch (ab) Engine START/STOP (iii) Blank (iv) Annuciation (LED Type): (Faults) (aa) Engine fails to start (ab) Low lub oil pressure (ac) High water temperature (ad) Generator over load (ae) Battery Voltage (af) Low fuel level (v) Additional features:- (aa) Continuous reading digital voltmer/Ammeter/freqauency meter (ab) Multifunction meters (ac) Electronic (with counter display)KWH Meter. (vi) Relay consisting of following features. (aa) 3 Phase mains supply voltage sensing (ab) Earth fault (ac) Earth leakage (ad) LED Indications (ae) Engine ON, Load on DG (af) Mains On, Load on Mains (ag) overload (vii) Push buttons (AMF Module by pass mode):- (aa) Engine START/STOP (ab) Geneator contactor CLOSE/TRIP (ac)Mains contractor CLOSE/TRIP (ad) Fault ACCEPT/RESET (viii) Engine Meters:- (aa) Lub oil pressure (ab) Water Temparature (ix) Battery Charger:- SMPS Based automatic float cum boost battery charger with following :- (x) Bypass switch of suitable rating | ||||||||
| 2.07(m) Accessories :- (i) 01 No standard mechanical and electrical tool box. (ii) Internal covered tube lights. (n) Acoustic Enclosure :- Specially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent, 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles. (a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination (b) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door.(p) Painting Scheme ISS shade 220 olive green 1994 or all as per manufacturers specifications (q) Lifting/ Transportation arrangements :- Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation. (r) Trials:- Trials on site should be given as per load tests prescribed and all functional trials should be shown. Note : (i) The Engine, alternator, Control Panel, Acoustic enclosure shall be integrated unit sourced and AMF panel,to be installed outside shall be from OEM only as per Make given in Sch 'A' | ||||||||
| 2.08Notes :- (i) Testing of DG set shall be carried out by Officer nominated by GE. The cost of POL & resistive load required for testing the DG Set is deemed to be included in quoted rates. The DG Set shall run for a period of 12 Hours continuosly out of which 15 minutes on No Load , 2 Hrs 15 minutes of 25% rated load, 2 hrs on 50% rated load , 2 Hrs 30 minutes on 75 % rated load, 4 Hrs on rated full load, 1 Hrs on 110% rated full load. (ii) First filling of coolant, Engine Oil, lubricants and fuel etc should be arranged by contractor for complete testing and quoted rate deemed to be inclusive for the same. (iii) The Contractor shall submit technical specifications and General Arrangement drawings of OEM for approval before placing order. (iv) The contractor shall submit the foundation drawing of OEM for approval . The contractor shall visit site before quoting the tender for ascertaining the complete work required. Any excess earth strip from earth test point to DG set shall be provided at no extra cost and quoted rate is deemed to be inclusive for the same. | ||||||||
Updated dates
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
10 Mar 2026, 6:00 pmClosed
GE AF NAL
GE AF NAL
As mentioned in BOQ
2026_MES_751757_1
GE (AF) NAL /T-75/2025-26
Open Tender
Electrical and Maintenance Works
150 days
GE AF NAL
As per NIT and Tender Documents Class E and above and Category b(i)
9 documents required · 9 mandatory
₹500
GE AF NAL
₹38,800
Yes
9 May 2026
7 Feb 2026
12 Mar 2026
7 Feb 2026
10 Mar 2026
24 Feb 2026
Supply, laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed.
Supply, install, test and commissioning of 82.5KVA/66 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty operation, with STD control panel , consisting of AMF feature to be errected at location indicated, all mounted in acoustic enclosure and Control panel as per manufacturers design and specification confirming to norms of CPCB IV+ and latest CPCB amendments complete with the following:- i) DG Fuel tank of minimum capacity for 12 Hr runing in with fuel gauge etc complete all as , ii) Battery & Leads iii) Silencer as per OEM design & recommendations complete as per latest CPCB norms. iv) AVM Pads v) First Fill of Lube vi) Acoustic Enclosure vii)Standard Control Panel (AMF) with connected switchgear/relays/meters complete to be errected at location indicated. (viii) Suitable size RCC cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. (ix)The cost of foundation bed incl earth work etc wiil be paid separately. (x) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted.
xi) The details specifications appended below :- (I) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, with 50°C intake air temperature, latest CPCB Euro emission engine ,turbocharged four stroke engine developing minimum 104 BHP @ 1500 RPM under NTP conditions, coupled to alternator mounted on Channel Iron base frame complete accessories etc .The prime mover provided should be as per IS specifications. (b) Air intake system should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.. (c ) Exhaust System should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. d) Fuel System should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be provided externally/separately. (e) Cooling System should comprise of radiator designed, hospital type silencer and tested for 50°C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine.
(f) Lubricating System should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free battery of capacity 12 V DC - 02 Nos with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator. (h) AC Generator The generator shall be horizontal and foot mounted,minimum82.5 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for voltage regulation + 1% , an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details:- (i) Type, Brush less AC Generators with PMG and space heater as per OEM design (ii) Output rating 82.5 KVA (iii) Output Voltage: 415 ± 1% under all loading conditions and with maximum voltage Dip at full load 0.8 PF shall be < 19% as per OEM design. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. (vii) Enclosure : Minimum IP-23 / Drip proof and screen protected.
(l) Standard Control panel with AMF feature ,door, slopy canopy type for 82.5 KVA DG set as per OEM design to be errected outside as indicated/directed. Standard Control panel with auto mains failure (AMF) feature complete , floor mounted type, vertical, factory made outdoor type, double door , canopy, fabricated out of 3.00 mm thick CRCA sheet with angle iron base frame made of 50 x 50 x 6mm or channels at base of Panel board floor mounted, dust and vermine proof, suitable for voltage 415 V Three Phase 4 wire, 50 HZ AC supply, weather proof, with separate hinge door for each compartment & locking arrangement, with back door openable (Screwed), legs welded/bolting complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN) of suitable rating, suitable double compression copper cable glands and including provn of the following :- (i) Protection relays as per OEM design/approved make. (ii) Minimum 160 A ,4P 36 KA EDO type MCCB of qty/capacity all as per OEM design (iii) Suitable rated resin cast CTs. (iv) Suitable rated inbuilt AVR. (v) SMPS based automatic battery charger, 24V, 20A with DCV, DCA -02 Nos. (vi) Digital Multifunction meters with RS 485 with LAN port hub. (xi) Suitable capacity copper control cables, necessary indications, hooters, auxilliary contactors, TNC & LVM interlocking etc. (vii) Provn of scope for future expansion for additioning of 1 No DG set from side end extension. (b) BACK-UP PROTECTION :- HRC Fuse for short circuit protection. (c) MICRO PROCESSOR BASED AMF MODULE :-
(m) Accessories :- (i) 01 No standard mechanical and electrical tool box. (ii) Internal covered tube lights. (n) Acoustic Enclosure :- Specially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent, 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles. (a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination (b) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door.(p) Painting Scheme ISS shade 220 olive green 1994 or all as per manufacturers specifications (q) Lifting/ Transportation arrangements :- Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation. (r) Trials:- Trials on site should be given as per load tests prescribed and all functional trials should be shown. Note : (i) The Engine, alternator, Control Panel, Acoustic enclosure shall be integrated unit sourced and AMF panel,to be installed outside shall be from OEM only as per Make given in Sch 'A'
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in Including spreading, levelling. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for tiba sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. Note:- Punned thickness shall be measured for payment.
M& L for Earthing of machinery/ equipment installed at power house /substation, using Galvanised Iron earth plate eletcrode of size 600 x 600 x6 mm thick as buried directly in ground (earth pit not less than 3mtr below normal ground level connected to GI earth strip 32 mm x 6 mm thick by means of bolts nuts,check nuts and washers at complete etc all as shown in electrical plate No-3 of SSR part-1 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type CI MS frame 50mm thick pre cast RCC (1:1½ :3) nominal mix cover slab reinforced with 8mm dia mild steel bar including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50mtr and funnel with watering pipe wire mesh GI protection pipe 40 mm bore including testing earthing complete all as specified and directed by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_841978.xls
BOQ • 0.31 MB
TENDER_T75.pdf
Tender Documents • 1.56 MB
Download all tender documents and submit your bid