| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹8.0 LAccepted-Finance | 1st | Accepted-Finance 1st lowest bidder | |
| 2 | 2nd₹9.1 L+₹1.1 L (14.3%)Rejected-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | 2nd | Rejected-Finance 2nd lowest bidder | |
| 3 | 3rd₹10.0 L+₹2.0 L (25.5%)Rejected-Finance BAKSI BAJAR KOTYALI PASCHIM MIDNAPUR PIN 721101 KOLKATA WEST BENGAL | KOLKATA | PASCHIM MIDNAPUR | WEST BENGAL | 721101 | 3rd | Rejected-Finance 3rd lowest bidder | |
| 4 | 4th₹10.2 L+₹2.3 L (28.7%)Rejected-Finance | 4th | Rejected-Finance 4th lowest bidder | |
| 5 | 5th₹10.4 L+₹2.4 L (30.1%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | 5th | Rejected-Finance 5th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹18,455
Closing Date
5 Aug 2024, 12:00 pmClosed
Superintending Engineer, SWEC, PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
SITC of silent DG set, UPS and AC machines alongwith related EI work within the campus of Government Fish Technology Station (G.F.T.S) at Junput in the dist of Purba Medinipur-- Electrical Installation with allied works
2024_WBPWD_717232_2
WBPWD/SE/SWEC/NIQ23/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,455
O/O of SE, SWEC,PWD, PWD Compound, Midnapur
10 Mar 2025
29 Jul 2024
7 Aug 2024
29 Jul 2024
5 Aug 2024
31 Jul 2024
31 Jul 2024
Amount
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand-Myrius or equivalent make of Philips/ Crabtree) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand-Myrius or equivalent make of Philips/ Crabtree), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Legrand-Myrius or equivalent make of Philips/ Crabtree), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand-Myrius or equivalent make of Philips/ Crabtree), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand-Myrius or equivalent make of Philips/ Crabtree) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required. Dimension of Cu. bars size 4x (4 x20x5mm), Rating 415 V, 200 A
Supplying and fixing 415V, 125 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make L&T / Siemens / Havells]
Supplying and fixing 415V, 32 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make L&T / Siemens / Havells]
Supply & Laying of 1.1 kV Grade XLPE insulated Armoured Aluminium Cable of 4 core 25 sqmm size on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting (Make- Polycab / RR Kabel / Gloster) (From Busbar to D.G and D.G to Changeover)
Supply & Laying of one No 1.1 kV Grade XLPE insulated Armoured Aluminium Cable of 4 core 25 sqmm size in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed (Make- Polycab / RR Kabel / Gloster)
Supply & Laying of 1.1 kV Grade XLPE insulated Armoured Aluminium Cable of 4 core 25 sqmm size with 2x10 SWG GI wire through existing GI Pipe
Supplying & fixing 50mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured incl. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials [Size : 4 Core 25 Sqmm.]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment i. No. of Way : 6 Way ii. Incomer : Supplying and fixing 240/415 V MCB type FP 63A Isolator on din rail of existing DB -1No. iii. Outgoing : Supplying and fixing 240/415 V MCB SP 6-32A of Breaking capacity 10kA & C characteristics on din rail of existing DB-18 Nos. [Make : Legrand or equivalent model of Siemens / Schneider]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. i. No. of Way : [2 + 12 Way] ii. Incomer : Supplying and fixing 240/415 V MCB type DP 40 A Isolator on din rail of existing DB -1No. iii. Outgoing : Supplying and fixing 240/415 V MCB SP 6-32A of Breaking capacity 10kA & C characteristics on din rail of existing DB-12 Nos. [Make : Legrand or equivalent model of Siemens / Schneider]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment i. No. of Way : 4 Way [Upto 160A] ii. Incomer : Supplying and fixing 415 V FP 125A MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DB -1No. iii. Outgoing : Supplying and fixing 240/415 V MCB TP 63A of Breaking capacity 10kA & C characteristics on din rail of existing DB-4 Nos. [Make : Legrand or equivalent model of Siemens / Schneider]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment [6 Way, Horaizontal]
Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A, TPN & Earth Metal Industrial Plug socket & 63A Industrial top incl. S&F 63 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.(Make- Legrand Cat No. 507864 (3p+N+E) /ABB/Siemens (For UPS)
Supplying & Fixing 4 way MCB SS enclosure, incl S& F 63A FPMCB with IP-20/30 protection , powder coated provision for two/ four MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (RR Kabel / Polycab / Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x80/0.4 (6 sqmm) + 1x84/0.3 (4 sqmm) as ECC .From TPN BDB to 2+12 way SPN BDB .(In 20mm dia 3mm thick polythene pipe in wall)
Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (RR Kabel / Polycab / Gloster) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2x(4 sqmm)+1x (2.5 sqmm) (For AC)
4 x 10 sqmm) + 2 x 6 sqmm) ECC From Proposed 200A BBC to HTPNMCBDB, existing 125A TPNMS to UPS & UPS to HTPNMCBDB (In 25mm dia 3mm thick polythene pipe in wall)
4 x 16 sqmm + 2 x 10 sqmm ECC From proposed 200A Busbar to proposed 125A changeover and connection of existing 125A TPN MS to proposed 200A BBC & connection of proposed C/O to existing 125A BBC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supply & Fixing of 240 V 1200 mm AC ceiling fan complete with blades, canopy, fork, rubber bush, safety wire, S3 capacitor etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ Make Usha STRIKER or equivalent model of Orient / Crompton ]
Providing cement concrete foundation suitable for erection of the 30 kVA DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation.
Excavation of soft soil for installation of Earth Electrode and filling & ramming.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI-Medium GI pipe ( For Body earthing of DG-2nos & Neutral Earthing-2 nos)
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
M/S JOGMAYA ENTERPRISE
M/S SREE GURU CONSTRUCTION
M S KAMAL SHAW
RASH ELECTRICAL WORKS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .