Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹83,740
Closing Date
12 Nov 2026, 6:00 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE Jaipur
GE Jaipur
SPL REPAIR TO YBO LINE QTR NO. P-05/1 TO 06 OF MH JAIPUR ALONGWITH MINOR WORK UNDER ZONE-II AREA AT JAIPUR MIL STN
2026_MES_795154_1
GE/J- /2026-27
Open Tender
Civil Works
Item Rate
180 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
GE Jaipur
₹83,740
Yes
22 Oct 2026
22 Oct 2026
14 Nov 2026
22 Oct 2026
12 Nov 2026
6 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of reinforcement cement Concrete of any description and in any position not otherwise specifically provided for as specified and directed by Engg-in-Charge. | 1 | Cum | - | - |
| 2 | M&L for RCC (nominal mix) 1:1.5:3 Type A1 (using 20 mm graded stone aggregate ) as in Chhaja, roof projections, slab supported on wall, beams, and columns, balconies, canopies, deck slab and in shelves and the like etc.complete all as specified & directed.
Note :- Reinforcement shall be measured and paid for separately. | 1 | Cum | - | - |
| 3 | Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.and similar items with rough finished surface of concrete complete all as specified and directed. | 5 | Sqm | - | - |
| 4 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for rough finished surfaces all as specified and directed. | 4 | RM | - | - |
| 5 | M&L Mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diameter including all necessary scaffolding, machinery, tools tackels and men materials complete all as specified and as directed by Engr-in-charge. | 178.5 | Kg | - | - |
| 6 | ,--- ditto--- all as per srl item No. 5 above but TMT bar of 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as directed and specified. | 39.25 | Kg | - | - |
| 7 | Taking down cement plaster or cement lime plaster, any description on brick, stone walls or concrete surface of ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed | 650 | Sqm | - | - |
| 8 | M&L for applying SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment, (consumption Qty as per manufacturer’s instructions but min 0.4 kg/Sqm approx) including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items using nylon brush complete all as specified and as directed by Engineer-in-charge.
Make:- Sika- Latex SBR / Fosroc-Nitobond SBR Latex / Asian SmartCare Repair Polymer, JKM or equivalent as approved by GE | 60 | Sqm | - | - |
| 9 | M&L for 15 mm thick polymer-modified mortar on load-carrying RCC members applied in two layers, comprising approved polymer, cement and graded quartz sand in the proportion of 1:5:15 by weight, with water as per manufacturer's recommended water-cement ratio for desired consistency. Surface shall be properly cleaned and prepared before application. The mortar shall be uniformly applied, finished by floating/trowelling and properly cured after initial setting complete as per manufacturer's specifications and direction complete all as specified and directed by the Engineer-in-Charge. | 50 | Sqm | - | - |
| 10 | M&L for 30 mm thick polymer-modified mortar on load-carrying RCC members applied in two layers, comprising approved polymer, cement and graded quartz sand in the proportion of 1:5:15 by weight, with water as per manufacturer's recommended water-cement ratio for desired consistency. Surface shall be properly cleaned and prepared before application. The mortar shall be uniformly applied, finished by floating/trowelling and properly cured after initial setting complete as per manufacturer's specifications and direction complete all as specified and directed by the Engineer-in-Charge. | 10 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
Tender.pdf
Tender Documents • 1.46 MB
BOQ_891797.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .