Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹25.5 L+₹1.8 L (7.71%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹27.2 L+₹3.5 L (14.7%)Rejected-Finance 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | L3 | Rejected-Finance Other than the lowest bid | |
| 4 | L4₹27.5 L+₹3.8 L (16.2%)Rejected-Finance | L4 | Rejected-Finance Other than the lowest bid |
Tender Value
₹30.4 L
EMD Value
₹60,820
Closing Date
29 May 2023, 6:00 pmClosed
Garrison Engineer (West) Jalandhar Cantt
Kabir Road Jalandhar Cantt
Provision of Air Conditioner for Testing Hall , Discussion halls and Conference Hall at Selection Centre North and other sanctioned works under GE (West) Jalandhar Cantt
2023_MES_592453_1
GE/JAL(W)-10/2023-24
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (West)
₹60,820
Yes
21 Jun 2023
1 May 2023
5 Jun 2023
1 May 2023
29 May 2023
17 May 2023
Amount
Supply and installation of Split AC white colour with copper condensor and cooling coil of 2 TON cap, (HOT & COLD) with indoor and outdoor unit with copper coils complete with all fittings and fixture including cordless remote control, copper gas pipe with thermal insulation upto 3.5 metre including PVC cable of 2.5 sqmm 3 core , gas charging, electric connections, vapour waste water pipe up to 5 metre length of PVC 15mm dia including making good to the disturbed wall surface and complete testing after insulation all as specified and as directed by Engr-in-charge.
S&F Sheet metal enclosure with socket and plug top and MCB SPN enclosure with 2 pin & earth plug and socket complete with single pole MCB 20 Amp, 240 Volt all as specified and directed
Supply and fix Voltage stabilizer, copper wound with metal plug top complete, for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core to be laid in trenches/ along pole etc complete
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core to be laid in trenches/ along pole etc complete
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core to be laid in trenches/ along pole etc complete
Supply and laying GI Tube Med grade 50mm dia including fittings complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m in depth for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, sewage line etc. and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed.
M&L river sand in trenches as cable cushioning 8 cm below the cable and 15cm above the cable all as specified and directed.
Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed.
Supply and lay burnt old size bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed.
Supply , installation & commissioning MCB Load Distribution board VTPN 4 way double door, for mounting MCCB/DP/ SP/TP/ MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed at site .
Supply , installation & commissioning MCB Load Distribution board TPN 4 way double door, for mounting DP/ SP/TP/ MCBs/MCCBs as incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet complete
Supply and Fix 4 Pole MCCB 63 to 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 40 to 100 Amps complete with connection testing and commissioning
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 25 to 63 Amps complete with connection testing and commissioning
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 32 Amps complete with connection testing and commissioning
M & L for sub main wiring with four single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire. (Six runs of cable and one run of conduit shall be measured as one length)
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 4 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit not less than 25mm in size complete with all accessories alongwith provn of one run of 4 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.(Three runs of cable and one run of conduit shall be measured as one length)
Supply & fixing in replacement, suction and discharge pipe line of 1st quality copper, size ½” and 3/8” or 5/8” duly insulated along with 2.5 Sqmm 3 core flexible copper cable PVC sheathed complete all as specified and directed.
Supply & fixing PVC rigid conduit drain pipe for AC water outlet of size 20mm including all fittings complete all as specified and directed.
M&L for earthing complete with GI steel earth plate electrode 60x60cmx6.00mm thick buried directly in ground / earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4mm as earthing lead soldering/ revited to earth plate at one end and connect to DB by means of nut, bolts etc complete with PCC pit (1:3:6) type C1, MS cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors
Taking down unserviceable Submain/Cable of any size as directed by Engineer-In-Charge.
Taking down main switch / DB as directed by Engineer-In-Charge.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of not less than 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.(Three runs of cable and one run of conduit shall be measured as one length)
M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of MODULAR TYPE switch/sockets and regulator and including modular type cover plate white colour all as specified and directed for: One light / fan / call bell point controlled by one, one way switch.
One 3 pin socket out let 5 Amps on same board with other switches.
One 3 pin socket out let 5 Amps on Independent board with other switches.
All as per item No. 28.00 above but with 2.5 sqmm multistranded copper conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board
S&F switch piano 5 Amp flush button type SP one way, 230 Volts, AC complete
S&F switch piano 15 Amp flush button type SP two way, 230 Volts, AC complete
S & F socket out let multipurpose 5 pin 6 Amps, flush type, 230 Volts complete
S & F socket combination 6 pin 15 Amp flush type multipurpose 230 Volts AC complete
M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl 01x 09 Watt LED bulb complete all as specified and directed.
S & F stepped socket type electronic fan regulator and connecting up complete 230/250 V as directed by Engr - in-Charge.
S&F LED tube light fitting 20W (Double side) including vetrofit LED lamp 20W with 2400 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50mm 3 core complete all as specified and directed.
Taking down heavy duty V3 600mm sweep wall mounting fan and repairing, rewinding, replacing fan bearing, fan capacitor and refixing the same as directed by Engr-in-Charge
S & F DB double door SPN 8 Way for MCB 240V with 200 Amp rated bus bar complete
S&F MCB SPN 32 to 63 Amps 240 volts complete
S&F MCB SP 6-32 Amps 240 volts complete
Dismantling of brick tiles single layer as in roof covering complete all as specified
Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part thereof) all as specified.
Roughening for old concrete surface/floor by picking, weeping clean and washing with down with water to remove dust including brushing neat cement slurry @ 3.00 Kg of cement per sqm etc. complete
M&L for PCC 1:2:4 type B-1 as in roof padding to bring the existing slab in slope of 1:40/concrete benching/coping etc complete all as specified
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.25kg per sqm incl cleaning surfaces over bitumen primer @0.30kg/sqm complete all as specified
M&L for fixing APP based polymeric membrane minimum weighing 3.60 kg/sqm and min 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm) land on primed surface by forced application complete
M&L 40mm thick brick tiles laid on cement mortar bed 1:6 , 15 mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement complete all as specified and directed.
All as per Ser item No 50.00 above but except tiles.
M&L for precast reinforced cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in manhole covers and similar articles, set in cement mortar 1:4 including necessary form work and demolition of existing covers and similar articles complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling floor hearth wall tiling (but not backing) removing servicable tiles to store rubbish off the premisses complete all as specified and directed
M&L glazed ceramic digital colour tiles 300mmx450mm x7mm thick set and jointed in neat cement slurry and pointed in coloured cement on vertical surfaces such as skirting/dado over & including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed
Demolition of cement Concrete(unreinforced) of any description and in any position not otherwise specifically provided for (below or above ground level) or as in sunken complete.
M&L non skid ceramic colour tiles 7 to 8mm thick joint free edge cut area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm set and jointed in neat cement slurry in floor and pointed in colour cement to match the shade including sceed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) complete
All as per ser item No 57.00 above but as in vertical surface including cement mortar in 1:4 rendering 10 mm thick complete
Taking down cement plaster on brick wall suface raking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L rendering 15mm thick in cment mortar 1:4 (upto two storey) on fair faces of brick or concrete surface of wall rendering is to be finished even & fair complete all as directed by the Engineer-in-Charge.
M&L preparation of new surfaces of walls and applying two coats of cement base paint complete all as specified and directed
Cutting of road / hard standing foot path not exceeding 0.30m wide and 0.6 mtr depth for laying of pipe line including making good with PCC 1:3:6 type C2 complete all as directed.
Supply and laying Galvanised mild steel water tubing, medium grade, ISI marked, 25mm bore, including all fittings fixed complete to walls and ceilings / laid on floors/ground and in trenches all as specified and directed.
All as per item No. 63.00 above but 20 mm bore.
Supply and fixing gunmetal globe/gate valve with iron wheel head, screwed both ends of 25mm size ISI marked, including all fixing accessories all as specified and directed.
All as per Ser item No 65.00 above but suitable for pipe of 20mm size
Supply and fixing GI connection clamp set of two with 20 mm socket suitable for 150 mm bore pipe as per sample complete all as specified.(Note : Excavation and earth will be measured and paid separately)
M&L for cement concrete Type D2 (1:4:8) using 40mm graded stone aggregate as in foundations,filling and mass concrete complete
M&L for cement concrete Type C2 (1:3:6) using 40mm graded stone aggregate as in foundations,filling and mass concrete complete
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement plaster (1:3) complete
Mild Steel framed work as in doors or gates of angle iron and other sections including pintle hinges etc. Gde Fe-410-O or Fe-310-O complete including welding drilling ec with rails and guides fastening/fixing complete
Supply, fabricating and fix valve chamber cover with handle made out of MS plain sheet of thickness 1.6 mm as per IS 2062 of various sizes as per existing valve chambers on angle iron frame of dimensions and painting one coat of red oxide primer and two coats of synthetic enamelled paint as directed
CHOUDHARY AND SONS
M/S Kuldip Construction Co.
ARR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .