| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹21.8 L+₹65,981.60 (3.12%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹22.9 L+₹1.7 L (7.96%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹25.5 L+₹4.4 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹25.6 L+₹4.5 L (21.1%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
REPAIR AND REPLACEMENT OF SECURITY LIGHT PERIMETER LIGHTS AND ALLIED WORKS AT RESDL AND TECH AREA OF ALISDA CEPTAM MTRDC RESDL AND TECH AREA OF GE I R AND D WEST BENGALURU
2025_MES_708410_1
GE(I)/R ND D (WEST)/BAN/TOKEN/25 OF 2025-26 8389/E8
Open Tender
Civil Works
Item Rate
270 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹80,000
8 Jul 2025
16 May 2025
23 Jun 2025
17 May 2025
16 Jun 2025
2 Jun 2025
17 May 2025 - 31 May 2025
Amount
Attending the commplaints connecting / disconnecting the loose wire/ UG Cable of street light / security/ flood light / postop lantern Light checking the serviceablity condition of any type of light, rate included for arrangement of ladder or scafolding. All as specified and directed.
Supply and fix in replacement LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fix in Replacement of LED Street/ security light fittings with lamp,45W,lens & toughened glass IP 66, with high lumen output, environmental friendly, energy efficient LED, street light fitting with lamps and accessories including GI piping Bracket suitable bend for holding street/ security light, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, complete all as specified and directed.
Supply and fix in replacement LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with complete all as specified and directed
Supply and fix in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with complete all as specified and directed
Supply and fix in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in repalcement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in replacement LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in replacement LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in replacement post top lantern LED type 40 watt conical in shape 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specied and directed.
Material and labour for detaction of any type of fault in LT under ground line of any size and core (laid in soil at plane area or forest area) with the help of Lt Megger. Seggregation of faulty span by meggering and making span serviceable by repair of cable Note : Item No 30,31,32,33&34 (a) Detection of one fault in faulty span will be measured as Each Job. (2) Earth work and taking out will be measured seperately. (3) Material for repair and replacement willbe measured saperately.
Supply and fix in replacement / installation of cable junction box made of high quality DK thermoplastic of size 200X160X98 mm including four number connection terminals suitable mouted on DN rail for alumn cables upto 25 sqmm 4 core with one single pole MCB 'C' curve type of current rating 6 amps and rupturing cap 10 KA complete with thermoplastic cable glands and fixed on GI Pipe and using pole clamps made out of appropriate material all as required at site or directed including inspection/ site testing (after installation at site) by company engineer. (Note: GI pipe measured separatally) Make: HENSEL /Sintex/ MECO or eqvivalent.
Supply and Replacement / installation of erection of steel tubular swaged pole 9mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm height upto 1.5 mtr above ground level all as required at site or directed by Engr-in-charge.
M & L for Painting to steel tubular pole swarn neck type/9/11 mtr long including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, street light bracket complete including painting with five strips of 30cm each black/yellow and silver paint(as per existing paint) in alternate strips from the base of pole upto 1.5mtr height complete, marking the pole No, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
Supply and fixing in repalcement of MCCB four Pole 415 Volts, 400 Amps, adjustable type with breaking capacity 36KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Supply and fixing in repalcement of MCCB 4 Pole 415 Volts, 250 Amps, adjustable type with breaking capacity 36KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Supply and fixing in repalcement of MCCB 4 Pole 415 Volts, 200 Amps, adjustable type with breaking capacity 16KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Supply and fixing in repalcement of MCCB 3 Pole 415 Volts, 200 Amps, adjustable type with breaking capacity 16KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Supply and fixing in repalcement of MCCB 3 Pole 415 Volts, 160 Amps, adjustable type with breaking capacity 16KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Supply and fixing in repalcement of MCCB 3 Pole 415 Volts, 25 to 100 Amps, adjustable type with breaking capacity 16KA including taking out old unserviceable MCCB complete all as specified and directed. Make : Indo Asian/Standard/C&S/L&T/Legrand
Excavation in trenches in hard/dense soil not exc 1.5 metre wide not exc 1.5 metre in depth; for laying of cables not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 mtr in depth for foundation in hard/dense soil and getting out all as directed.
Returning filling including spreading, levelling , watering and well ramming in layers n.exc 25cm in soil as directed .
Removing of excavated soil to a distance not exc 50 m & depositing where as directed at a level n.exc 1.5m above starting point all as specified and as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
Taking down existing 1100 Volts grade cable size up to 35 sqmm 3.5 core from in trench, wall, ceiling, culvert and pole and laying only XLPE insulated, tesing complete all as specified and directed.
Supply and fix in replacement cable of XLPE insulated armoured LT cable 1100 volts grade of size 10 Sqmm 2 core, in tenches / on walls /poles including suitable MS clamps for fixing, connecting , testing and commissioning for building service connections complete all as specified and as directed. NOTES :- Earthwork, sand filling, brick protection shall be measured and paid separately under relevant items of this schedule.
All as per item 24 here in before but cable size 16 sqmm 4 core
All as per item 24 here in before but cable size 35 sqmm 3 1/2 core
All as per item 24 here in before but cable size 50 sqmm 3 1/2 core
All as per item 24 here in before but cable size 70 sqmm 3 1/2 core
M&L for cable straight through joint kit, heat shrinkable type for XLPE/PVC cables of size up to 50 to 70 Sqmm 3 1/2 core with working voltage 1100 Volts Make: Dension/M Seal
M&L for cable straight through joint kit, heat shrinkable type for XLPE/PVC cables of size 95 Sqmm 3 1/2 core with working voltage 1100 Volts Make: Dension/M Seal
Supply and fix in replacement of light grade Galvanised mild steel pipe 32mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule )
Supply and fix in replacement of Tri colour light column pole 3 mtr 50w LED light column with di-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP 65 protection with tricolar and tratic out put switch complete including PCC foundation and electric connection Cat part No BLSLC50W LED TRI3M of Bajaj or equvalent of CG/Philips/shakti
Taking down existing LED street light fitting, model SLE UL, 100/120 Watts IP 66 LXN for servicing, calliberation and repair of CC LED driver (PCB) with input voltage 240 V AC 50 Hz and refixing in position by providing LED 100/120 watts to make it functional complete all as specified and as directed. Make :- SURYA, CG, PHILLIPS or as approved
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, two core 1100 volts grade fixed on panels/walls/Street Light connection complete all as specified and as directed.
Material and Labour for aluminium lugs up to 185sqmm as per site requirement complete all specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6.3 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia bymeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified.
S & F in replacement Street light bracket made out of 40 mm dia light grade GI Pipe not less than 1.5m length, bent to shape including 2 Nos, 50 x 6 mm FI Clamps nut,bolts washer etc complete including necessary painting work all as specified and directed.
RRK PROJECTS (BID ID -3325444)
Pacific Enterprises (BID ID -3317400)
Sahara Engineers (BID ID -3316646)
GS TRADERS (BID ID -3323605)
ADR ENTERPRISES (BID ID -3317242)
KAALIKA ELEVATORS (BID ID -3317025)
NAVEEN ENTERPRIESES (BID ID -3316455)
Solar Electricals and Electronics (BID ID -3317480)
ARUNOTHAYA TRADERS (BID ID -3321272)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .