EXECUTIVE ENGINEER PROVINCIAL DIVISION AMRITSAR
EXECUTIVE ENGINEER PROVINCIAL DIVISION AMRITSAR
Retrofitting of District and Session Judge and District Attorney Office for Persons with Disability at Amritsar
2026_CEPW_160259_2
EE/PD/Asr 90 dated 13/02/2026
Open Tender
Civil Works - Buildings
Percentage
120 days
AMRITSAR
Please refer Tender documents.
16 documents required · 16 mandatory
₹5,000
Yes
₹1.6 L
Yes
14 Feb 2026
14 Feb 2026
2 Mar 2026
14 Feb 2026
2 Mar 2026
14 Feb 2026
CIVIL WORK
Parking Facility and Tactile/Guide Path outside building for PwD (2 Nos)
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Footing
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Steel work in hip & jack rafters common rafters purlins etc. with angle cleats and other connecting plates
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick
Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Cutting of floor topping of concrete / Kota Stone / any kind of marble/ tile floor depth up to 50mm with the help of mechanical cutter and chisel (with due care so that surrounding floor should not be damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm to 28mm thick cement concrete 1:2:4 as per requirement complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge.
Toilets for PwD (G+5 storey) (1 Nos)
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Door Lintel
Ground floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Ground Floor (Ist level)
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Third Floor
Fifth Floor
Extra rate for Third Floor
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
12.5 mm thick cement plaster 1:4.
20mm thick cement plaster 1:4 in two coat work.
Extra for Smooth Surface of Ceiling.
Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Fifth Floor
Extra rate for Fifth Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Third Floor
Fifth Floor
Extra rate for Third Floor
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fourth Floor
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For fixed portion & Chaukhat
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Pre-laminated particle board with decorative lamination on one side.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing an fixing MS of Double action spring hinges with necessary screws etc. complete 100mm
Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Ground Floor
First Floor
Extra rate for Second Floor
Second Floor
Extra rate for Second Floor
Third Floor
Extra rate for Third Floor
Fourth Floor
Extra rate for Fourth Floor
Fifth Floor
Extra rate for Fifth Floor
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Toilets for PwD (G+1 storey) (1 Nos) in ADR Center
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Door Lintel
Ground floor
First Floor
Extra rate for First Floor
Ground Floor (Ist level)
First Floor
Extra rate for First Floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Ground Floor
First Floor
Extra rate for First Floor
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Ground Floor
First Floor
Extra rate for First Floor
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
Ground Floor
First Floor
Extra rate for First Floor
Second Floor
Extra rate for Second Floor
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
12.5 mm thick cement plaster 1:4.
20mm thick cement plaster 1:4 in two coat work.
Extra for Smooth Surface of Ceiling.
Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
First Floor
Extra rate for First Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
First Floor
Extra rate for First Floor
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete
Ground Floor
First Floor
Extra rate for First Floor
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.
Ground Floor
First Floor
Extra rate for First Floor
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing
Ground Floor
First Floor
Extra rate for First Floor
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Ground Floor
First Floor
Extra rate for First Floor
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For fixed portion & Chaukhat
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Pre-laminated particle board with decorative lamination on one side.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing an fixing MS of Double action spring hinges with necessary screws etc. complete 100mm
Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Ground Floor
First Floor
Extra rate for Second Floor
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing SS Railing along wall to Existing Stair case
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
Providing and fixing acrylic Braile indicators of size 170mm x 35mm to be fixed on handrails of the the approved design and make having Braile dots raised 0.5mm above base plate, to the installed at the specified locations as per the directions of the Engineer-in-Charge complete s per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-Charge
Upgradation of Information, Safety Sinage & Emergency Exit for Person with Disability
Providing and Installation of Safety signage as per guideline for person with disability made of retro reflective sheeting as per colour specified and writing matter will be of same material in white fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washer complete as per specification and as desired by engineer in charge.
Informatory sign board 800x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
Providing and laying 50 mm wide antiskid tape made of slip resistant material colour contrast, edge strip, self adhesive to be fixed on front edge of Stair treads to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Providing and laying 25 mm to 50mm wide high intensitiy reflective conspicuity tape colour contrast, edge strip, self adhesive to be fixed on front edge of Stair riser to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Upgradation of doors hardware, Resting facilities & Tactile/Guide path inside building etc for PwD
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Cutting of floor topping of concrete / Kota Stone / any kind of marble/ tile floor depth up to 50mm with the help of mechanical cutter and chisel (with due care so that surrounding floor should not be damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm to 28mm thick cement concrete 1:2:4 as per requirement complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge.
Removal of Door Shutter (Panneled/Glazed), for providing vision panel, repairing and refixing the same in original position as per specification and as desired by engineer in charge. (including Cost of new hinges, Screw, class, bidding & providing vision panel not exceeding 0.1 sqm complete as per specifications) in square/rectangle
Providing & Installation of Sitting Benches 3 Seater made of S.S 1800mm in length, 900mm width, 500mm sitting height, without arm, seat & back shall be made of 10strip S.S pipe 63mm x 25mm of 18 guage to be fixed in floor bymeans of rawl metal plug in corridor for resting purpose complete as per specification & as desired by Engineer-in-Charge. (wt not be less than 25kg)
Sub Work-1 Internal Water Supply, Sewerage, Sanitation
Sub Head-1 Internal Sewerage System
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A
110mm o/d single socket SWR UPVC pipe lines laid complete
75mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm i/d pipes
Elbow 90 Degree (All side socketed)
Single Tee With Door
For 75mm i/d pipes
Elbow 90 degree (all side socket)
Single Tee With Door
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
uPVC Pipe 6 Kgf/cm2 50mm i/d
Sub Head-2 Internal Water Supply System
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
CPVC SDR 11 pipe & Fittings 25mm o/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 16mm o/d
CPVC SDR 11 Pipe & fitting 20mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
qty same as GI P 15mm i/d to 25 mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 22.86 cm thick
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
15mm i/d G.I. Union
20mm i/d G.I. Union
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
20mm i/d Brass Ball valves
25mm i/d Brass Ball valves
Providing ISI Marked G.M ferrule as per IS:2692, drilling and tapping cast iron pipe lines of all diametres and screwing in Ferrule and connections complete in all respect.
Sub Head - 3 Sanitary Installation
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 550 mm x 400 mm x 815mm
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body foam flow without flange
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion C.I.bib cock as per IS:210 with stainless steel spindle of approved make (to the approval of Engineer-in-charge ) complete in all respect. 15mm i/d
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm Angle valve without flange
C.P.brass 15mm Concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 1500mmx600mm or any other size
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
C.P. brass toilet roll holder with flap
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
35mm dia 900mm (36”) long
35mm dia 1200mm (48”) long
Foldable U Type 762mm long
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Brass Ball Cock with rod and Plastic Ball 25mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 20mm i/d
G.I. tank nipple 25mm i/d
Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltrs
Sub Work-2
Estate Sewerage
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110 mm o/d pipes
160 mm o/d pipes
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
For depth exceeding 3.0 m but not exceeding 4.5 m BGL For all classes of soil except rocky
For depth exceeding 3.0 m but not exceeding 4.5 m BGL For all classes of soil except rocky
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard
Inside size 90x150 cm with depth 120 cm between bottom of top slab and invert ( with MH cover & frame Heavy duty)
Providing Internal Electrical Installations for Toilet
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:-
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring light point
Wiring fan point (With fan box)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Make:-Polycab,L&T,Goldmedle, V-Guard, KEI, Grandlay, Ultracab, RR kabel, , Havell's, Greatwhite Securex,Rellison,or equivalent.
Overall size 1.5sq.mm (Un-sheathed)
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
MINIATURE CIRCUIT BREAKERS:-
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- GROUP-A: Siemens (Beta Guard), Legrand (Lexic) , Schneider (Acti-9), L&T (Exora),Hager
MCB Single Pole 6-32amp. (10kA, Curve-C)
Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make:- Crompton- EXHD300-6-1/HAVELL's -Turbo Force SP/ ORIENT Havey Duty Exh.or equivalent.
Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make:-PHILIPS-BN02IC LED20S PSU CW GRS2/CROMPTON -CCS-103-20-65-SL-DP-NWH/HAVELL'S-ENDURALINEARNEOBS20WLED865SPCWH/BAJAJ-BCLAB 20W WH LED P/WIPPRO-LL20-281-XXX-65 AL1/EVEREADY-LEDBTA02016-02
Providing Emergency alarm system consisting of following devices & accessories:- Electronic emergency Unit to Installed inside of outside Toilet, Moisture proof Micro-switching unit to be installed One at height of 300mm from the floor & second at height of 900mm from the floor level inside Toilet for activating alarm the over door outside indicator provides an audible & visual signal to indicate the area where assistance is required complete as per specification & requirement defined in Harmonised guidelines & space standards for barrier free built environment for PwD& Elderly persons.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_325358.xls
BOQ • 0.87 MB
drawingretrofitting.pdf
Additional Documents • 4.17 MB
SBDRETRO_compressed.pdf
Tender Documents • 12.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .