Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.8 LAdmitted-Finance | +4.11% | ₹8.8 L | L1 | Admitted-Finance |
| 2 | L2₹9.8 LAdmitted-Finance | +15.51% | ₹9.8 L | L2 | Admitted-Finance |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
19 Jan 2026, 3:00 pmClosed
SE CIVIL JVVNL, Kota
SE CIVIL JVVNL, NEAR GOVT. COLLEGE, NAYAPURA, KOTA
Augmentation of sub-office, yard development and extension and other misc civil work at 33/11 KV S/S Bhadoti and Malarna Doongar.
2025_JVVNL_520941_15
E-NIT 06/2025-26
Open Tender
Civil Works
180 days
Bhadoti and Malarna Doongar.
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO (O and M)JVVNL, TONK Through NEFT/RTGS/IMPS/UPI
₹38,000
Yes
27 Jan 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
B-1/1.28:- Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.:-All kinds of soil
B-1/1.8:- Earth work in excavation by mechanical means (hydrolic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sum on plan) including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kinds of soil.
B-3/3.1.6:- Providing and laying in position cement concrete including curing compaction etc. Complete in specified grade excluding the cost of centrering and shutteting -All work up to plinth level (A) 1:4:8 (1 cement 4 coarse sand : 8 graded stone aggregate 40 mm Nominal size.)
(B) M15 grade N.Mix 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm Nominal size.) (B-3/3.1.2)
B-5/5.2.2 : Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
B-10/10.17.1 :-Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
B-10/10.22:Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
B-12/12.7:- Finishing with neat cement (punning).
B-14.2.1:-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
B-12/12.3.2:- Plaster on new surface on walls in cement sand morter 1:6 including racking of joint etc. Complete fine finished (A) 20 mm thick.
B-13/13.1:- Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
B-12.35.7:-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ).
B-9/9.19.3 : Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) .
B-9/9.26 : Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
B-9/9.27 : Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
B-8/8.13.2.1 : Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :comercial veneer both side 30 mm thick .
B-12/12.22.1:- Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete : New Plastered Surface (three or more coats)
B-12/12.37.1: Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer.
B-12/12.42:- Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
B-12/12.41.1:-Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm).
B-12/12.46.1: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
B-12/12.65: Spray painting in approved shade and approved quality with Duco paint of required colour to give even shade with two or more coats by compressor including sand papering, NC putty filler coat etc complete in all respect as per design given by Engineeer incharge on new work.
B-13/13.4.1: Renewing glass panes,with putty and nails wherever necessary : Float glass panes of thickness 4 mm
B-14/14.25: Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
7.25.1 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600mm
7.5.6(ii) Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Rajasthan Black 1501 Cm2 to 3600 Cm2 Tiles
7.6.2(i) Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work Full Edge moulding
B-7/7.12+7.14 :- Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
B-7/7.13+7.14 :Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
S-1/1.2.2:- P&F indian type white glazed vitreous china 1st quality W.C. orissa pan (IS: 2556 Mark) with 100 mm viterious china Por S trap including cutting and making good the wall and floor. Size 580x440mm.
S-1/1.36.4:- P&F WVC wash basin 1st quality (IS:2556 mark) of approved make with CI brackets duty painted one no. 15 mm CP piller cock (IS: 8934 mark) & 32 mm CP brass waste coupling of approved make 25 mm dia GI waste pipe complete including cutting and making good the wall. size 580×450 mm.
S-2/2.38.2:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) (a) 20mm nominal size
(b) S-2/2.38.4:- 32mm nominal size
S-2/2.39.1:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). 15 mm dia nominal bore.
(B) 25mm dia nominal bore
S-2/2.3.1:- Making connection of GI distribution branch with GI main including all fitting : Upto 25mm dia
S-2/2.7.3:- P&F bibcock (IS : 8931 Mark) superior quality of approved make : C.P. Brass bib cock,15mm nominal bore.
S-2/2.11.2 :- P & F Ball cock (IS : 1703 Mark) with Rod & P.V.C. Ball completeBrass wt. 400 gm. 20mm
S-2/2.12.1:- P&F inlet connection (Angle velves) superior quility of approved make for washbasin Gyset etc. CP intel connection 15 mm Brass (IS: 8931 marked)
S-2/2.14.3:-P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :exposed 25mm nominal bore.
S-2/2.15.1:- P&F Full way valve (IS: 778 mark) or wheel valve of approved make. (A) 2.15.1:- Gunmetal 15mm nominal bore
(B) 2.15.3:- Gunmetal 25mm nominal bore
S-2/2.26.3:- P&F PVC storage tank (IS: 12701 marked including the BIS license No.) of approved make with cover,25 mm dia IM long over flowing & 25 cm. Long wash out pipe with plug & socket, including making connection etc. Complete of approved deisgn : (A) 500 liters capacity.
S-3/3.16.3:- P&F rigid PVC pipe (IS:4985 mark) class II (4 KG./cm 2) appoved quality/ make incliding joint the pipe with solvent cement rubber ring and lubricant : 110 ,mm dia
S-3/3.17:- P&F rigid PVC pipe (IS:4985 mark) of appoved quality/ make incliding joint the pipe with solvent cement rubber ring and lubricant : 110 mm dia. (A) 3.17.9:- Bend 87.5˚
(B)3.17.12:- Vent Cowel
(E) 3.17.15(ii): Pipe Clip
S-1/1.14.1: P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete : Flat Back (small) size 456x355x265mm.
S-3/3.22.3:-Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 Cm. dia outside & 240 Cm. depth.
S-3/3.27.1 :-Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR (A)LED Street Light fixture with Minimum lumen output 11225 lm (E-18.12.6)
E-18.18.3 Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .32mm
4.3 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
B-4/4.10.2:- Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
B-4/4.13.1:- Providing fabricating reinforcement for RCC work including straingtening, cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor Five level : cold twisted deformed bars (IS:1786).
B-15/15.29:- Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification: Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.
B-13/13.12 Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
B-8/8.31 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.
B-9/9.3.1:- Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete: Hot finished welded type tubes.
B-17/17.1:- Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding.
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Earth work in filling of excavated earth except back cotton Soil With watering and Compaction of Spreaded earth in 15-30 cm layers, levelled and neatly dressed as Per requirement of site and direction of engineer in charge, work includes cost of earth with taxes, loading, unloading, transporation, labour, water and T&P etc. Complete with all lead and lift.
Stacking of laid crusher broken ballast from yard,screaming & relaying of the same in the same yard as per specification in layers not exceeding 15cm (loose) as per specification including dressing etc. complete for all lead and lift complete as per direction of engineer in charge
Collection, transportation (all lead) & spreading (including hand ramming) of crusher dust including stacking as the standard specification in layers not exceeding 15 cm (loose) incld. dressing etc complete. For all lead and lift complete as per direction of engineer incharge. with compaction by Plate vibrator.
Supply and spreading of graded crusher broken hard stone aggregate free from organic matter including stacking & sperading in yard as per standard specifications of size 63mm- 45mm including all lead and lift transportation, labour, loading, unloding T&P rquired for gravelling work as per direction of Engineer in charges including dressing & levelling.
Repair of existing boundary wall gate (inc. wicket gate if required) by providing necessary hinges/sleeve, flat, pins, certain missed member of pipe, welding, transportation etc complete for all lead & lift as per direction of engineer incharge. Item also including removing of gate frieght charges with rent of welging machine upto site and back.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.37 MB
Tendernotice_2.pdf
PDF • 2.31 MB
BOQ_940427.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid