| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC | ₹4.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.4 Cr+₹5.8 L (1.34%)Rejected-Finance | ₹4.4 Cr+₹5.8 L (1.34%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹5.0 Cr+₹65.7 L (15.2%)Rejected-Finance A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | ₹5.0 Cr+₹65.7 L (15.2%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹5.2 Cr+₹86.1 L (20.0%)Rejected-Finance | ₹5.2 Cr+₹86.1 L (20.0%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹5.2 Cr+₹89.3 L (20.7%)Rejected-Finance | ₹5.2 Cr+₹89.3 L (20.7%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
4 Oct 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
PROVN OF AREA DRAINAGE SYSTEM UNDER GE FARIDKOT
2023_MES_617581_1
CE BTZ/FDK/TOKEN-08 OF 2023-24
Open Tender
Civil Works
Lump-sum
182 days
Faridkot
as per NIT
9 documents required · 9 mandatory
₹2,000
GE Faridkot
₹5.5 L
Yes
28 Oct 2023
7 Sept 2023
6 Oct 2023
7 Sept 2023
4 Oct 2023
21 Sept 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Sch 'A' Sec - II, (INTERNAL ELECTRIFICATION WORKS)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 03 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
All as per above Srl item No. 03 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc.including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
Supply only switch piano flush type, 5/6Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge.
Supply only switch piano flush type, 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge.
Supply only Socket outlet multipurpose type 5/6 Amp, flush type complete all as specified and as directed by Engineer-in-charge.
Supply only Socket outlet multipurpose type 6/16 Amp, flush type complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 380mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 20 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Subtotal
Lump sum price worked out by the tenderer for “PATH & CULVERT WORKS" as listed in Schedule ‘A’ Section -III (Part-I)
Sch 'A' Sec - III (Part-II), (PATH & CULVERT WORKS)
Material and labour for cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, hard standing etc, with provision of panels size as directed and surface finished even & fair including necessary form work complete all as specified and as directed by Engineer-in-charge. (Note : Joint filing shall be measured & paid separately under appropriate item )
Material and labour for Forming Construction joint 30mm deep x 10mm wide and filling the Joints with and including bitumen and sand (1:3) by weight complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “STORAGE POND WORKS" as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), (STORAGE POND WORKS)
Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in bed of drain pipe of size 600mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for mild steel work for making openable gate system suitable for 600mm dia pipe to control water flow inside storage sump as directed by GE made out of MS plate, guide channel, flat iron etc. including welding work complete all as specified and as directed.
Material and labour for chequered cement concrete coloured tiles (with grey cement & pigment) of size 30cm x 30cm, 25mm thick laid as in floor/path, set jointed and pointed in neat cement slurry with grey cement and pigment to match the shade of tile, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 110mm dia grade 'A' uPVC pipe 200mm long weep hole with the slope of about 1:20 horizontal towards drainage face including 300x300x200mm drainage filter wrapped with wire mesh complete all as directed by GE.
Mild steel bars of TMT (CRS) 10mm dia and over, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS)" as listed in Schedule ‘A’ Section -V
Sch 'A' Sec - VI (AREA DRAINAGE WORKS)
Supply, installing, commissioning and testing of non clog centrifugal pumpset capacity 3000 LPM discharge at the head of Approx 35 Mtr, factory assembled electric driven centrifugal pump ,horizontal split casing pump multistage CI body with CI impeller std fitted and Carbon steel shaft, mounted on heavy duty bearing connected with electric driven 3 phase, Sq-cage AC motor of suitable capacity , 1450 RPM , 3 phase 440 V AC Supply ,50 Hz with MS base frame including PCC Foundation and all accessories like coupling nut, bolts, gland packing, washers or any other petty items required for fixing complete all as specified and as directed.
Supply, installing, commissioning and testing of non clog centrifugal pumpset capacity 3000 LPM discharge at the head of Approx 45 Mtr, factory assembled electric driven centrifugal pump ,horizontal split casing pump multistage CI body with CI impeller std fitted and Carbon steel shaft, mounted on heavy duty bearing connected with electric driven 3 phase, Sq-cage AC motor of suitable capacity, 1450 RPM , 3 phase 440 V AC Supply ,50 Hz with MS base frame including PCC Foundation and all accessories like coupling nut, bolts, gland packing, washers or any other petty items required for fixing complete all as specified and as directed.
Supply, installing, commissioning and testing of monoblock electric driven pumpset of capacity approx 330 LPM discharge at the head of Approx 36 Mtr, factory assembled electric driven pump of capacity of suitable capacity, 3 phase 440 V AC Supply ,50 Hz, with MS base frame including PCC Foundation all accessories like coupling nut, bolts, gland packing, washers or any other petty items required for fixing complete all as specified and asdirected.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, nominal dia 250mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints ISI marked (Push-on joint, IS 5382/1985), pipe laid in trenches complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, nominal dia 80mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints ISI marked (Push-on joint, IS 5382/1985), pipe laid in trenches complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Cast iron pipe 300mm nominal dia, centrifugally cast, class 'B', (ISI marked, IS:1537-1976) with both ends flanged and drilled including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supplying, laying, jointing and testing Cast iron pipe 100mm nominal dia, centrifugally cast, class 'B', (ISI marked, IS:1537-1976) with both ends flanged and drilled including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supplying, laying, jointing and testing Mild steel pipes of size 250 mm bore, Heavy duty, thickness not less than 8mm, conforming to IS 3589, including suitable flanges & fittings and jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed. Note :- MS pipe shall be laid below road crossing and welded in centre and both ends flanged, and shall be tested as per IS is done.
Supply and fixing cast iron sluice valve 250 mm bore with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve 100 mm bore with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve 80 mm bore with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing 250 mm bore cast iron body non return valve (NRV) with bypass arrangement, confirming to IS 5312 (ISI marked), both flanged ends and drilled, including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing 80 mm bore cast iron body non return valve (NRV) with bypass arrangement, confirming to IS 5312 (ISI marked), both flanged ends and drilled, including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing 300 mm bore cast iron body foot valve, confirming to IS 4038 (ISI marked), including jointing material complete all as specified and as directed.
Supply and fixing 100 mm bore cast iron body foot valve, confirming to IS 4038 (ISI marked), including jointing material complete all as specified and as directed.
Supply and fixing cast iron double air relase valve isolating type (ISI marked), flanged type and drilled, confirming to IS-14845, 80mm bore including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Supply and fixing /DI fitting upto 250 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed. Note:- Make of fittings shall be same make as DI pipe or as per recommendation of manufacturer.
Supply and fixing fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt, suitable for 50 HP, Amp range 28-42 complete all as specified and as directed.
Supply and fixing fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt, suitable for 60 HP, Amp range 37-50 complete all as specified and as directed.
Supply and fixing DOL electric motor starter, push button type, suitable for 7.5HP, 3 phase 415 V, AC electric motor complete all as specified and as directed.
Supply and fixing/laying PVC flat sheathed (flexible) industrial cable with copper conductor of size 25 Sqmm, 3 core, 1100 Volt grade heavy duty including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
Supply and fixing/laying PVC flat sheathed (flexible) industrial cable with copper conductor of size 6 Sqmm, 3 core, 1100 Volt grade heavy duty including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
Material and labour for boring of holes (trenchless) under main road pavement, hard standing or any other situation by manual mean for accommodate upto 250mm bore DI pipe in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (DI pipe shall be measured and paid separately)
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION AND DG SET WORKS" as listed in Schedule ‘A’ Section - VII (Part-I)
Sch 'A' Sec - VII (Part-II), (EXTERNAL ELECTRIFICATION AND DG SET WORKS)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Sand cushioning, with dry and clean river fine sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.
Material and labour for boring of holes (trenchless) under main road pavement, hard standing or any other situation by manual mean for accommodate upto 80mm bore GI tube in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GI pipe and cable shall be measured and paid separately)
Supply and fixing three core (3x1.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through LT steel tubular poles or drawn through 20mm PVC conduite along PCC pole for connection to street light from junction box to light complete all as specified and as directed. Note :- GI Pipes if required same shall be measured and paid seperately under respective item.
Supply, installing, commissioning and testing of factory made LT panel board (CPRI approved) (indoor type for 415 volts, 3 phase, 4 wire AC supply, free standing, floor mounting) cubical type suitable size made out of CRCA epoxy powder coated 2mm thick sheet, factory fabricated having modern fabrication and testing process process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front open able hinged independent door for each compartment and common open able hinged door from rear side, with locking arrangement (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on pedestal frame made out of MS channel of size ISMC 50mm, both side properly welded and all vertical corner grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) including painting to pedestal frame with spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer. Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 200 Amps
MCCB 125 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 01 No (Incoming)
MCCB 100 Amps, Three pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 02 No (Outgoing)
MCB 20 Amps, SPN, 10 KA, AC supply - 02 No (Outgoing)
Indicating lamps set RYB - 01 Set of three
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply and fixing cable junction box of minimum Size 210mm x 155mm x 92mm or any other higher size complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 66 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded and 63 A four pole terminal stud. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and grey color according to RAL 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 2 pole stud type terminal, with one number 2.5 Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS-304
Supply, installing, commissioning & testing energy efficient of transformer suitable for 160 KVA step down pole mounted outdoor type 11/0.433, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked level 3, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manually operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent. The transformer shall be comprised with the following fittings and accessories
(a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) Explosive vent (g) 01 No 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two Nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strength (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints complete all as specified (r) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover.
Note :- (a) Transformer shall be Pre-Commisioned by SEI after installation, before issue of completion. (b) Cost of all necessary T&P and measuring devices shall be provided by the contractor without any extra cost. (c) Drawing of transformer shall be approved by GE before placing the order. (d) Any other item which is required for efficient functioning of transformer is deemed to be included in the quoted rate.
Supplying, installing, commissioning and testing complete of manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set, radiator cooled, with AMF panel capable of delivering 62.5KVA (50 KW) or nearest higher rating 415 volts AC 3 phase, 4 wire system of supply, 50Hz. The DG set shall consist of diesel engine coupled through flexible coupling to matching alternator and mounted on foundation pads on common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per CPCB norms and as specified) with AMF control panel standardised by manufacturer, inbuilt fuel tank, flexible exhaust pipe, incl necessary PCC foundation as per manufacturer instructions complete all as specified and as directed and comprising with the following:--
Alternator : AC alternator, self-excited, self-regulated, self-ventilated, brushless design, confirming to BS 2613/5000, 3 phase, 415 volts, 4 wire rated line current min 56 Amps output at PF 0.8 (lagging), 1500 RPM, insulation class ‘H’ enclosure IP 23 complete with AVR with ± 1% voltage regulation, directly coupled to and matched with engine.
Diesel Engine: Adequate capacity Diesel Engine capable of 62.5 KVA coupled with alternator and after considering derating as per site conditions and power consumed by accessories. The engine shall be directly coupled through closed coupling, turbo charged after cooled, multi cylinder, multi stroke direct injection, cold starting and shall confirm ISO 3046 / BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous operation. The engine shall be electric start and shall be suitable for battery assisted Manual / Auto starting. The governing system of the engine shall be electric type and suitable to frequency variation with in ± 1% in case of load is switch on or thrown off and comprising with the following:-
(i) Turbo charger, pulse tuned exhaust manifold. (ii) Cooling System: Mounted radiator with fan and belts & guard, corrosion inhibitor coolant etc. (iii) Silencer: Residential type. (iv) Exhaust System: Exhaust system complete with flexible stainless steel piping of suitable dia 2.5 mtrs above the adjacent bldg as per OEM standard with necessary supports and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure. (v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Fuel injection system with fuel injectors, filters, houses, fuel injection solenoid switch and nozzles. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. (viii) Lub oil pump, filter and collier. (ix) Intake system: Air intake manifold with dry type air filters. (x) Engine and alternator shall be mounted on common base frame with AVM pads. (xi) Mounted micro processor based control panel having standard features and display engine and electrical parameters. (xii) The engine supplied with first filling of oil of required quantity as recommended by OEM. (xiii) All deliverable shall be confirmed the norms established by CPCB.
AMF Panel: Auto Main Failure (AMF) Panel out door type made out 3.15mm CRCA sheet weather proof powder coated conforming to IS 8623 and IP-54 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 110% load of 62.5 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable. AMF panel shall house adequate capacity contactors for smooth transfer of load between mains and DG set. Panel shall be operated with three modes of operation. 1. Auto, 2. Manual, 3. Test. and comprising with the following:-
(i) Contactor of Suitable capacity 3 pole with required Nos. as per OEM, TP contactor for natural for both supplies. (ii) Suitable capacity of MCCB, 4 Pole for both supplies. (iii) CTs 150/5A for both the supplies. (iv) Push buttons. (v) Indication Lamps. (vi) Over load + earth leakage relay (vii) Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. (viii) SMPS Battery charge 12V, with trickle and boost charging. (ix) ON/OFF Switch. (x) Automatic / Manual Switch. (xi) Hooter. (xii) Voltage sensing relay. (xiii) Six window anunciator for fault indications.
Acoustic Enclosure : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions with the following features: -
(i) Custom built product for various equipment’s, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against wreathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyester powder / epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (vii) The DG set should be provided with the external emergency stop push button and fire alarm. (viii) A see through transparent window in front of engine panel to be provided for monitoring the parameters. (ix) Working space is to be provided around the equipment for easy maintenance / repairs.
(x) Necessary cut out provision for entry and exists of fuel lines cable to be incorporated in the enclosure as per the requirement. (xi) See through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (xii) Ducting if required, bellows, mechanical hardware like locks, hinge, and fasters etc to be provided. (xiii) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturer’s recommendations above ambient temp. (xiv) The enclosure should be provided with bulk head light fitting for inside illumination. (xv) The exhaust pipe along with proper aluminium cladding shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates. (xvi) The batteries should be placed inside the enclosure inside the DG set on a suitable insulated platform. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xx) The acoustic enclosure parts shall be of powder coated after pre treatment process.
Anti-vibration pad for mounting engine alternator assembly on the base frame/plate.
Base frame/plate made out of structural steel as per manufacturer’s recommended design/specifications.
01 No 12 volt x 88 AH maintenance free batteries complete with suitable size copper lead.
The contractor shall supply following maintemance spare part and tool kit for the generator set :- (i) Fuel filter - 02 Nos (ii) Lube oil filter - 01 No (iii) Air filter - 01 No (iv) V-belt - 02 Sets (v) Tool kit socket set - 01 No (vi) DE Spanner set - 01 No (vii) Ring Spanner set - 01 No (viii) Clamp meter - 01 No
Note :- (i) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted. (ii) DG set should be sound proof as per latest policy (iii) Cost of maintenance free batteries as per recommendations of manufacture shall deemed included in unit rate quoted by contractor (iv) Cost of PCC foundation as shown in drawing shall deemed included in unit rate quoted by contractor. (v) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (vi) Exhaust from DG set shall be as per latest CPCB [II] norms. Alternatively emission control device within overall cost quoted shall be provided (vii) Pre commissioning test shall be carried out by rep of Accepting Officer. All necessary equipment’s, consumables, artificial load for testing, DHPP for testing purpose and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - VIII
BANSI CONSTRUCTION COMPANY
AP BUILDERS
Vinod Kumar Bajaj
A.V BUILDERS
M/s Kataria Construction Company
GAURI SHANKAR AGGARWAL
SOM BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .