Loading…
Loading…
Tender Value
₹17.7 Cr
EMD Value
₹10.3 L
Closing Date
1 May 2025, 11:30 amClosed
Design, Supply, erection, testing and commissioning of 50 Hz, 2x25 KV OHE including modification of existing OHE in connection with Kashi Yard remodeling Phase-I, 3rd line between Shivpur-Varansi and Design, Supply, erection, testing and commissioning of 50 Hz, Single Phase 1x25 KV OHE in connection with by pass line at Shahganj and Jaunpur of Lucknow division Northern Railway
142-Dy-CEE-C-LKO-2024-25
142-Dy-CEE-C-LKO-2024-25
Open
12 Months
Jaunpur, Uttar Pradesh
₹0
₹10.3 L
4 Apr 2025
4 Apr 2025
1-OHE SOR SECTION-I (GENERAL)
2-OHE SOR SECTION-II (CONCRETE)
3-OHE SOR SECTION-III (FERROUS)
4-OHE SOR SECTION-IV (NON-FERROUS)
5-OHE SOR SECTION-V (INSULATOR)
Item Breakup - 1-OHE SOR SECTION-I (GENERAL)
Each Supply without insulator and erection of material for termination of Single conductor of Over head equipment or terminating wire.
Each Supply without Insulator and erection of material for termination of all aluminium 25KV Feeder / return conductor (Single SPIDER)
Each Supply without insulator and erection of materials for termination of copper cross feeder with gantries.
Set Supply without Insulator and erection of cut-in(9Tonne) Insulator
Each Supply without Insulator and erection of a suspension (9Tonne) Insulator
Each Supply without Insulator and erection of 25 KV Post Insulator
Each Supply, Erection, oil- filtration, testing and commissioning of L.T. supply transformers (10 kVA).
Each DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Supply and Erection, oil- filtration, testing and commissioning of L.T. supply transformers (25 kVA).
Each Supply without Insulator & erection of 25 kV D.O. fuse switch.
Each Modification to erected equipments :Transfer of equipment from one mast or support to another.
Each Modification to erected equipments :Dismantling of a Section Insulator Assembly
Each Total 1493448.00 Item- 2 Erection S No. Item No Description of Item Unit Qty Rate Amount Preparation of designs and drawings for overhead equipment and verification of purchaser's pegging plan.
Per Track Erection KM Supply without insulator and erection of mounting arrangements for span wire.
Each Marking/painting of temperature & 'Y'- Measurement of OHE mast at BWA locations
Each Supply without insulator and erection of material for termination of Single conductor of Over head equipment or terminating wire.
Each Supply without Insulator and erection of material for termination of all aluminium 25KV Feeder / return conductor (Single SPIDER)
Each Supply without insulator and erection of materials for termination of copper cross feeder with gantries.
Set Supply without Insulator and erection of cut-in(9Tonne) Insulator
Each Supply without Insulator and erection of a suspension (9Tonne) Insulator
Each Supply without Insulator and erection of 25 KV Post Insulator
Each Extra for special embedment of earth electrode.
Each Supply, Erection, oil- filtration, testing and commissioning of L.T. supply transformers (10 kVA).
Each Supply and Erection, oil- filtration, testing and commissioning of L.T. supply transformers (25 kVA). DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
Each Supply without Insulator & erection of 25 kV D.O. fuse switch.
Each Modification to erected equipments :Transfer of equipment from one mast or support to another.
Each Modification to erected equipments :Dismantling of overhead equipment.
Kilometre Modification to erected equipments :Splicing & extension of an anchored overhead equipment.
Each Modification to erected equipments :Dismantling of a Section Insulator Assembly
Each Modification to erected equipments :Slewing and putting back of OHE in original shape
Each Span Modification to erected equipments :Dismantling of an Isolator
Each Modification to erected equipments :Dismantling of a Post/ Pedestal Insulator.
Each Extra on erection rates (Items of sub- section - I) for work under a power block @ 100%
29.00 material for termination of Single conductor of Over head equipment or terminating wire.
8.00 material for termination of all aluminium 25KV Feeder / return conductor (Single SPIDER)
4.00 materials for termination of copper cross feeder with gantries.
40.00 cut-in(9Tonne) Insulator
34.00 suspension (9Tonne) Insulator
25.00 KV Post Insulator
4.00 indication
290.00 support to another.
& extension overhead equipment.
Each Total 1723716.80 DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
Item Breakup - 2-OHE SOR SECTION-II (CONCRETE)
cum Concrete for foundation and plinth In rocky soil
cum Concrete for foundation and plinth In other than hard soil and rock
cum Reinforced concrete
cum Supply & Spreading of Ballast/Gravel in the Switch Yard.
Sqm Total 4782490.00 Item- 2 Erection S No. Item No Description of Item Unit Qty Rate Amount Concrete for foundation and plinth In hard soil
cum Concrete for foundation and plinth In rocky soil
cum Concrete for foundation and plinth In other than hard soil and rock
cum Reinforced concrete
cum Supply & Spreading of Ballast/Gravel in the Switch Yard.
Item Breakup - 3-OHE SOR SECTION-III (FERROUS)
MT S u p p l y and erection of fabricated and galvanised structures (O,N & R type portals) with necessary components other than masts.
MT Supply and erection of Structure steel(traction masts) fabricated and galvanised Type : B-Series Mast
MT Supply & Erection of special fabricated and galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) &3(b)(ii)
MT Supply only of fabricated steel other than masts DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
MT Supply and erection of a Guy Rod Assembly
Each Supply and erection of Anchoring Arrangement of traction mast with Galvanised steel stranded wire
Each Supply and erection of 25KV Caution Boards including staff caution Board
Each Supply without insulator and erection of Single bracket assembly.
Each Supply without Insulator and erection of a pull off arrangement for one OHE.
Each Supply and erection of Regulating Equipment (3-Pulley type) with counter weight assembly for conventional/ composite OHE.
Each Supply without Insulator and erection of materials for termination of Double overhead equipment conductor.
Each Supply without Insulator and erection of anticreep with galvanized steel wire.
Each Supply & erection of a connection between return conductor and rail.
Each Supply and erection of a structure bond.
Each Supply and erection of a Galvanised steel stranded wire structure bond
Each Supply and erection of a longitudinal bond
Each Supply & erection of a transverse and special bond.
Each Supply & erection of a single earth electrode.
Each Supply and erection of anticlimbing device for L.T. Supply Transformer Stations.
Each Supply and erection of Danger Plate on a Height Gauge Structure
Each Total 39293332.00 Item- 2 Erection S No. Item No Description of Item Unit Qty Rate Amount Supply & Erection of traction masts, main masts of switching stations, Booster transformer station, fabricated from Rolled mild steel joist (RSJ) of size 203mm x 152 mm x 52.0 Kg/m and galvanised in various lengths .
MT DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY S u p p l y and erection of fabricated and galvanised structures (O,N & R type portals) with necessary components other than masts.
MT Supply and erection of Structure steel(traction masts) fabricated and galvanised Type : B-Series Mast
MT Supply & Erection of special fabricated and galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) &3(b)(ii)
MT Supply and erection of a Guy Rod Assembly
Each Supply and erection of Anchoring Arrangement of traction mast with Galvanised steel stranded wire
Each Supply and erection of 25KV Caution Boards including staff caution Board
Each Supply without insulator and erection of Single bracket assembly.
Each Supply without Insulator and erection of a pull off arrangement for one OHE.
Each Supply and erection of Regulating Equipment (3-Pulley type) with counter weight assembly for conventional/ composite OHE.
Each Supply without Insulator and erection of materials for termination of Double overhead equipment conductor.
Each Supply without Insulator and erection of anticreep with galvanized steel wire.
Each Supply & erection of a connection between return conductor and rail.
Each Supply and erection of a structure bond.
Each Supply and erection of a Galvanised steel stranded wire structure bond
Each Supply and erection of a longitudinal bond
Each Supply & erection of a transverse and special bond.
Each Supply & erection of a single earth electrode.
Each Supply and erection of anticlimbing device for L.T. Supply Transformer Stations.
Each Supply and erection of Danger Plate on a Height Gauge Structure DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
Each Extra on erection rates(Items of sub- section - III) for work under a power block @ 100%
19.00 masts of switching stations, Booster transformer station, fabricated from Rolled mild steel joist (RSJ) of size 203mm x 152 mm x 52.0 Kg/m and galvanised in various lengths .
37.50 galvanised structures (O,N & R type portals & Special Portals ) with necessary components other than masts.
and steel(traction masts) fabricated and galvanised Type : B-Series Mast
88.00 galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) &3(b)(ii)
300.00 Single bracket assembly.
2.00 pull off arrangement for one OHE.
and Equipment (3-Pulley type) with counter weight assembly for conventional / composite OHE.
45.00 materials for termination of Double overhead equipment conductor.
7.00 anticreep with galvanized steel wire.
2.00 for L.T. Supply Transformer Stations. Extra on erection rates for steel work manually under item 3(a)(i), 3(a)(ii), 3(b) (i),3(b)(ii) &3(b)(iii) @ 50%.
30.00 masts of switching stations, Booster transformer station, fabricated from Rolled mild steel joist (RSJ) of size 203mm x 152 mm x 52.0 Kg/m and galvanised in various lengths .
110.00 galvanised structures (O,N & R type portals & Special Portals ) with necessary components other than masts.
and steel(traction masts) fabricated and galvanised Type : B-Series Mast
265.00 galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) &3(b)(ii) Total 3994126.00
Item Breakup - 4-OHE SOR SECTION-IV (NON-FERROUS)
Kilometre DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Supply and Manual Erection of all aluminium 25KV Feeder/ Return conductor (Single Spider)
Kilometre Extra on item 6(az) for supply and erection of additional fittings at a turn-out, diamond crossing or overlap
Each Supply without Insulator & erection of a section insulator assembly
Each Supply & Erection of a Ceramic/beaded Glass Fibre type (PTFE) Short Neutral section assembly
Each Supply without Insulator and erection of a 25 KV single pole isolator without earth contact assembly.
Each Supply without Insulators & erection of 25kV Double Pole Isolator.
Each Supply & erection of large copper jumpers
Each Supply & erection of small copper jumpers
Each Supply & erection of copper jumpers
Each Supply & erection of a copper jumper for drop out fuse switch
Each Supply and erection of an aluminum jumper.
Each Supply of materials and erection of Large copper jumper 160 Sq. mm between Aluminium bus and cross feeders
Each Supply of materials and erection of Large copper jumper 160 Sq. mm between cross feeder and OHE
Each Supply and erection of copper strips for equipment earthing.
Metre Supply & erection of Solid copper bus-bars 18mm.:
Metre Supply & erection of solid copper bus-bar connectors: Bus terminal (6310)
Each Supply & erection of solid copper bus-bar connectors: Bus splice (6320)
Each Supply & erection of solid copper bus-bar connectors: Bus tee joint (6330)
Each Supply & erection of solid copper bus-bar connectors: Bus terminating tee (6351)
Each Total 5730523.00 DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Item- 2 Erection S No. Item No Description of Item Unit Qty Rate Amount Supply and erection of Over Head equipment only
Kilometre Supply and Manual Erection of all aluminium 25KV Feeder/ Return conductor (Single Spider)
Kilometre Extra on item 6(az) for supply and erection of additional fittings at a turn-out, diamond crossing or overlap
Each Supply without Insulator & erection of a section insulator assembly
Each Supply & Erection of a Ceramic/beaded Glass Fibre type (PTFE) Short Neutral section assembly
Each Supply without Insulator and erection of a 25 KV single pole isolator without earth contact assembly.
Each Supply without Insulators & erection of 25kV Double Pole Isolator.
Each Supply & erection of large copper jumpers
Each Supply & erection of small copper jumpers
Each Supply & erection of copper jumpers
Each Supply & erection of a copper jumper for drop out fuse switch
Each Supply and erection of an aluminum jumper.
Each Supply of materials and erection of Large copper jumper 160 Sq. mm between Aluminium bus and cross feeders
Each Supply of materials and erection of Large copper jumper 160 Sq. mm between cross feeder and OHE
Each Supply and erection of copper strips for equipment earthing.
Metre Supply & erection of Solid copper bus-bars 18mm.:
Metre Supply & erection of solid copper bus-bar connectors: Bus terminal (6310)
Each Supply & erection of solid copper bus-bar connectors: Bus splice (6320)
Each Supply & erection of solid copper bus-bar connectors: Bus tee joint (6330) DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
Each Supply & erection of solid copper bus-bar connectors: Bus terminating tee (6351)
Each Extra on erection rates (Items of sub- section - IV) for work under a power block @ 100%
of equipment only
4.00 aluminium 25KV Feeder/ Return conductor (Single Spider)
41.00 of additional fittings at a turn-out, diamond crossing or overlap
16.00 section insulator assembly
2.00 Glass Fibre type (PTFE) Short Neutral section assembly
6.00 25 KV single pole isolator without earth contact assembly.
5.00 drop out fuse switch
erection of jumper.
4.00 copper jumper 160 Sq. mm between Aluminium bus and cross feeders
4.00 copper jumper 160 Sq. mm between cross feeder and OHE
5.00 equipment earthing.
20.00 connectors: Bus terminal (6310)
6.00 connectors: Bus splice (6320)
4.00 connectors: Bus tee joint (6330) Extra on erection rates for stinging work manually under item 6(a),(b),(c)&(d) @ 50%.
of equipment only Total 1044866.00
Item Breakup - 5-OHE SOR SECTION-V (INSULATOR)
Each Supply of 9- Tonne insulators for item 5(a) (i), 5(b) & 5(c)
Set DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Supply of 9- Tonne insulators for item 8(b) (i),(ii),(iii), (iv),(vi),(vii), (viii)&(ix)
Each Supply of 9- Tonne insulators for item 9(a), (b), (c), (d) & (e)
Each Supply of 9- Tonne insulator for item 11(a) (i) &11(a)(ii)
190.00 11(b) Supply of 9 - Tonne and Sectioning Insulators for item No.12(a)
mm) Sectioning Insulator Supply of 9 - Tonne and Sectioning Insulators for item No.12(b)
14.00 item 13(a)
16.00 item 13(c)
Set Total 5231515.15
Item Breakup - 6-OHE NS ITEMS
Numbers Supply and erection of OHE caution board with supply of fixing material (Clamp, back flat strip & fasteners) for-Signal Board at neutral section for Electric Engine to SWITCH ON/OFF size 800mm x 400mm x 2mm(Retro reflevtive type) as per RDSO specification no ETI/OHE/33 a (12/97) rev-8 (11/2012) or latest and Drg no RE/33/348,349 rev-B or latest as per scope of work and explanatory note
Numbers Supply and erection of OHE caution board with supply of fixing material (Clamp, back flat strip & fasteners) for-'caution unwired turnout' board size 900x600x2mm as per RDSO specification no ETI/OHE/33 (8/85) or latest as per RDSO drawing no ETI/OHE/P/7573 Rev-A or latest as per scope of work and Explanatory Note
Numbers DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Supply and erection of OHE caution board with supply of fixing material (Clamp, back flat strip & fasteners) for-Electric Engine stop board size 900x600x2mm as per RDSO specification no ETI/OHE/33 (8/85) or latest as per RDSO Drawing no ETI/OHE/P/7572 Rev-B or latest as per Scope of work and explanatory note
Numbers Supply and erection of "caution clearance to OHE nearby restricted board" size 400 x 270 x 2 mm as per RDSO specification no ETI/OHE/33 (8/85) or latest as per RDSO Drawing no RE/33/436, Rev-C or latest as per scope of work and explanatory note
Numbers Supply and erection of "Dead section caution board" (Power block working limit board) Size 400 x 400 x 2 mm as per RDSO specifiaction no ETI/OHE/33 (8/85) or latest as per RDSO drawing no ETI/OHE/P/7574 or latest as per scope of work and explanatory note
Numbers Supply and erection of Shock treatment chart (glass framed) size 22x 18 " complete with aluminium angle beading 1/4" x 3/4 "all around
Numbers Supply and erection of Gate man/station master instruction board (glass framed) size 11.6" x 8.2 " complete with aluminium angle beading all around
Numbers Fabrication and supply of pre compressed particle laminated borads white in colour with aluminium beading 1/2" x 1/2" all around and an arrangement of fixing /hanging on wall of adequate strengh on top of boards required in size
Square Material + Erection Foot Development the sectioning diagram schematic diagram and TSWR diagram with computerised digital printing on adhesive vinyl of adequate size as per annexure -A and colour of as per provided in drawing
Square Material + Erection Foot Modificaiton in already developed diagram in different size with computerised digital printing on adhesive vinyl of adequate size and color as provided in Drawing
Square Material + Erection Foot Supply and erection of OHE wooden key box size 15"x10"x4.5"
Numbers Replacement of enamaled type number plate and supply & erection of retro reflective number plate in place of replaced enameled number plate as per RDSO Drg no ETI/OHE/P/7053 or latest along with fixing arrangement and stenciling on mast.
Numbers DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Design Manufacturing supply of retro reflective type sigma board as per RDSO drawing no TI/DRG/OHE/PLTBRD/RDSO/00036/12/0(Size 450mmx60mm) and RDSO specification no ETI/OHE/33A(12/97) Rev.8
Numbers Cost of GI clamp for mounting arrangement suitable for sigma board (4 nos ) including transportation.
Each Erection of GI clamps (4 nos ) including 4 nos 12 mm dia GI nuts & bolts 300 mm long (fully threaded) with necesssary washer spring wahser including retro reflective type sigma board on non reflective back gound at different OHE mast and portals including transportation
Each Total 568604.00 Item- 2 SECTION 6 B S No. Item No Description of Item Unit Qty Rate Amount NS-11:Dismantling of Mast
MT Extra on erection rates (for work under power block) for item no NS-11 @ 100% of erection rate
MT NS-12:Dismantling of Portal
MT Extra on erection rates (for work under power block) for item no NS-12 @ 100% of erection rate
MT NS-13:Dismantling of a Copper/ Aluminium jumper.
Each Extra on erection rates (for work under power block) for item no NS-13 @ 100% of Erection rate
Each NS-14:Shifting of OHE termination (Regulated) from one mast or support to another
Each Extra on erection rates (for work under power block) for item no NS-14 @ 100% of erection rate
Each NS-15:Adjustment on bracket assemblies for lowering/raising the height of contact and catenary wires where Encumbrance is changed.
Each Extra on erection rates (for work under power block) for item no NS-15 @ 100% of erection rate
Each NS-17:Shifting of OHE termination (Fixed ) from one mast or support to another
Each Extra on erection rates (for work under power block) for item no NS-17 @ 100% of erection rate DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY
Each NS-19:Loading, leading, transportation, unloading and stacking of steel structures & Conductors etc. from TRD stores to site and released material from site to the store
MT NS-25:Dismantling of Foundation of RCC/MCC cement concrete anywhere in Yard/Block section upto required level for all heights
cum NS-26:Hiring and operating multi utility vehicle (maximum 03 vehicle in a month) of loading capacity one MT with sitting capacity of 4-6 persons, 4 strokes, 4 cylinder engine, facorty built metal body, cargo box type passenger cabin type or bith (with 24 hours availability) including cost of fuel lubricants operating and maintenance including on pucca kucha road along the track the contractor shall arrange road permit for vehicle for all the states of opeation as per instruction of engineer in charge and vehicle shall not be more than three years old
Each/month NS-27: Extra on NS 26 for every additional Km or part thereof over 1200 Km
Vehicle Km 6000.00 NS-28: Route Mapping of OHE mast by OLIVER-G Kit with use of GPS system in 25 KV AC OHE System between section of Lucknow Division
Kilometre NS-33:Provision of double contact wire under ROB/FOB complete with supply of cactenary wire & contact wire excluding supply of contact wire
Each NS 29: Provision 3:1 type modified ATD with counter weight assembly for conventional OHE (regulated)2400kgf as per explanatory note.
Each NS-30: Supply and erection of erection of Aerial Earth Conductor (12.24 mm dia ACSR raccoon) with required fittings on Mast/Portal/TTC as per RDSO specification
Kilometre NS-31: Supply and erection of BEC(20 mm dia galvanized steel conductor) with necessary accessories fitting and fasteners as per RDSO specification
Kilometre NS 32 Supply and erection of large copper jumper of 160 sqmm size
Each NS-34 Digging of trench of size 300 mm deep
Kilometre DYCEE-C-LKO-ELECTRICAL/NORTHERN RLY Total 10883267.00