| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.4 CrAccepted-AOC | ₹6.4 Cr | 1 | Accepted-AOC Lowest bidder |
| 2 | 2₹8.0 Cr+₹1.6 Cr (24.4%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹8.0 Cr+₹1.6 Cr (24.4%) | 2 | Rejected-Finance Being not lowest bidder |
| 3 | 3₹8.6 Cr+₹2.2 Cr (33.8%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹8.6 Cr+₹2.2 Cr (33.8%) | 3 | Rejected-Finance Being not lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected due to Capacity of Solar work not meeting NIT criteria and Work Experience within last 05 Years for considering the enlisted contractor for enlistment in class A is not meeting NIT criteria |
| 5 | Rejected-Technical 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Rejected due to Solar power rating of firm or MOU firm and solar power work experience not uploaded |
Tender Value
₹6.1 Cr
EMD Value
₹6.3 L
Closing Date
30 Sept 2023, 6:00 pmClosed
CE (AF) Prayagraj
CE (AF) Prayagraj
PROVISION OF 1 MW GRID BASED SOLAR PLANT AT GE (AF) GORAKHPUR
2023_MES_600780_1
958809/E8
Open Tender
Civil Works
Lump-sum
365 days
Gorakhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE(AF) Gorakhpur
₹6.3 L
Yes
15 Jan 2024
3 Jun 2023
7 Oct 2023
20 Jul 2023
30 Sept 2023
16 Sept 2023
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/PATH AND CULVERT)
Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VIII
Sch A Part IX (FENCING AND GATE)
Lump sum price worked out by the contractor for Fencing and gate as listed in Sch ‘A’ Part IX.
Sch A Part X (Miscellaneous Items of B/R and E/M)
Design, Supply, install, testing and commissioning of ground based solar power generating system without battery of capacity 1.0 MW AC output peak grid tied solar photo voltaic system complete with the components specified below:- (a) Solar PV modules of minimum rating 335 Wp with minimum 72 cells, Poly Crystalline Module shall be certified as per IEC 61215-Edition-II, IEC 61646 and IEC 61730-1&2 complete all as specified. Qty of solar PV module shall be tentatively 3582 Nos for 1.0 MW AC output. Note:- (i) Design shall be done as per latest IS code, latest MNRE guidelines and specifications mentioned in tender from MNRE approved channel partner of rating as specified in NIT. Final design and drawing has to be vetted by any of the approved agency as mentioned in the tender (ii) Solar Modules and solar cells therein should be of Made in India. The contractor will have to submit respective company declaration in the format , to be provided by GE at the time of request for approval of sample/Make for modules. Each PV module used in this work shall have RF Identification tag. (iii) Solar PV modules shall be warranted for their output peak watt capacity, which shall not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar PV modules shall be warranted for any manufacturing defect or bad workmanship for a period of 25 years from the date of completion of Phase-I of the work. The contractor shall submit necessary warranty certificate for 25 years to GE.
(iv) Modules should be of Make as approved by MNRE. If no make has been approved, modules confirming to IEC standards mentioned above or latest specification issued by MNRE will be used in SPV system. (v) An amount equal to Rs 5,00,000 (Rupees Five Lakh Only) shall be retained from the contractor's bill against the warranty as performance guarantee for a period of 25 years from date of completion of job. Alternatively the contractor may give a separate interest bearing security deposit/BGB in favour of GE valid for 25 years. This amount shall be refunded to him by GE after a period of 25 years under the conditions provided from by the contract and arising solely from faulty materials or workmanship provided such defective parts are not repairable at site. (vi) During the period of warranty of modules, the contractor shall remain liable to replace any defective parts that become defective in the plant. (vii) Rate quoted will be inclusive of surface dressing and levelling upto 3m on all sides of solar panels array (b) Design Hot dip galvanized mild steel module mounting structure for solar panels of combined capacity 1.0 MW, AC output with double pole static structure of suitable size alongwith concrete grouting for required rigid support as required at site capable to with stand maximum wind load as designed for MS sections of modules all as required as per site. Mounting structure will be designed in such a way that lowest edge of solar panel is minimum 900 mm above the ground level.
(c) Central Inverter/PCU, DC to AC (indoor type) of capacity 2x500 KW AC or next higher side capacity suitable for 1.0 MW AC , with minimum DC inputs 4(+/-) each with SCADA capabilities as specified housed in OEM provided complete. Note:- (i) Power conditioning Units (PCU) PCUs shall be warranted for minimum period provided by the manufacturer but not less than 5 years. PCUs shall be warranted for any manufacturing defect or bad workmanship for a minimum period of 05 years from the date of completion of Phase-I of the work. (ii) During the period of Warranty the contractor shall remain liable to replace any defective parts that become defective in the plant under the conditions provided for by the contract and arising solely from faulty materials of workmanship, provided such defective parts are not repairable at site. After replacement the defective parts shall be returned to the contractor . (d) String monitoring/combiner box of type 22 in 1 Out with 10 Amp MCB/fuse on positive side, 200 Amp manual DC disconnector switch & 22 Channel monitoring as required at site complete.
(e) Copper DC String cables of different sizes of suitable size as required at site of Solar grade, including suitable lugs/male, female connectors etc. UV resistant 1.0 KV DC Cables confirming to IEC 62930:217/BSEN50618 temperature range -50°C to +90°C, complete. (f) Data monitoring system communication cable RS 485 [screen twisted] as required at site complete. (g) Inverter communication Shielded CAT-5 cables as required at site complete. (h) Supply, install, testing and commissioning of Solar Observatory system of Weather Station complete all as specified and directed consisting of following:- (i) Pyranometers: 1 No (ii) Rain Gauge: 1 No (iii) Module Temp Sensor:4 Nos (iv) Ultrasonic Anemometer:1 No (v) Temp & relative Humidity Meter: 1 No (vi) Solar Panel (35 W) + Battery Bank: 1 No (vii) Data Logger: 1 No
Note:- All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts old data simultaneously round the clock. All data shall be stored in a common work sheet chronologically Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen. with Remote Performance Monitoring System complete all as specified and directed by the Engineer-in-Charge and shall have following:- (i) Inverter Data Monitoring (ii) Energy Meter Data Monitoring (iii) Weather Station Monitoring (j) Lightening protection system of Early Streamer Emission type Lightening Spike with 107 m protection at level 3 for Protection (duly supported by tech literature) against lightning strikes with GI mast of 8.5 Mrs long Quantity of lightening arrester shall not be less than 3 Nos including suitable size of copper strip up to earthing pit . Foundation of system should be as advised by OEM / NISE Earthing shall be provided for string monitoring/combiner box, Inverter, Solar PV module, mounting structure, panels, LA complete with suitable size of Copper earthing and copper Cable / strip as earthing lead as per design including termination accessories as required at site & confirming to latest IS/IEC all as specified and directed. Earthing for isolation transformer and equipment thereafter downstream will be through GI strip earthing with GI earthing lead.
(k) Main distribution board, Floor Mounted DC Panel, DC Bus, Auxiliary Buses for required load as per site requirement on DC side of inverter complete. (l) Main distribution board Floor Mounted AC Panel, AC Bus, Auxiliary Buses for required load as per site requirement on AC side of inverter complete all as specified and directed. (m) UPS with battery bank of 5 KVA with 60 minutes backup at 100% load as per design & specifications for Solar System critical components, Industrial type on in UPS with static switches for bypass complete. (n) UPS distribution board of Floor Mounted UPS DB, indication lamp complete all as required at site. (o) Main DC Cables of size as required at site, Aluminium, armoured Cable confirming to _ IEC 62930:217/BSEN50618 temperature range -15°C to +90°C complete. (p) 1.1KV Aluminium Armoured LT power Cable as per IS 7098 from inverter to transformer of AC Cables of size as required at site including end joints , mid joints, complete all as specified and directed. (q) LT Aux (DC & AC) control cables for UPS input, transformer, Inverter, panels of suitable size, 1.1KV copper LT cable as per relevant IS complete all as specified and directed.
(r) Earth continuity conductor or main earthing lead copper cable or GI strip of suitable size as per design and as required at site. (s) Suitable size HDPE pipe 6kgf/cm2 rating for cable protection including all necessary fitting and fixing arrangement complete as required at site all as specified and directed. Note: Necessary earth work, sand cushioning, protection pipe bricks etc shall deemed to be included for laying of cables HDPE pipe up to power transformer. (t) Industrial type computer (One No) rugged & robust in nature to operate in a hostile environment. The computer shall be of HP make or of equivalent make having i10 of better processor with minimum 1 TB of hard drive, 21’’ LCD colour monitor, DVD Drive with writer multimedia kit and UPS with 30 min Power back up (u) Coloured laser printer (One No) as per HP model number M1005 or techno commercially equivalent model in other make as approved by GE. The printer shall be equipped for printing, scanning, copying etc complete. (v) Generation Metering : Suitable capacity generation digital meter arrangement with associated accessories viz CT, PT, metering box, wiring etc for commissioning with initial inspection from local electricity supply company. (w) Net Metering : Suitable capacity Net digital metering arrangement with associated accessories viz CT, PT, metering box, wiring etc for commissioning with initial inspection from local electricity supply company of rating/specification as per latest UPERC/CERC notification.
Note : Metering arrangement should be SCADA supported and have following features to measure and record (i) Parameters of current, voltage , PF and frequency (ii)Total units generated since installation (iii) Total units exported (iv) Total units consumed in house (v) any other metering required to determine efficiency. (x) Inverter duty step up transformer BEE Level 3, copper wound, outdoor type of 1250 KVA or nearest size on higher side suitable for stepping up AC voltage from Power Conditioning Unit / Invertor output voltage to 11 KV, losses confirming to IS-2026 including all latest amendments including first fill of transformer oil confirming to IS 335 , suitable plinth of size and design as per manufacturer instruction with slot and clamps for incoming and outgoing cable protection pipe complete all as specified and directed - 01 No (y) Isolation Transformers -2 Nos of 630 KVA or nearest higher capacity compatible with AC voltage of PCU including first fill of transformer oil confirming to IS 335 , suitable plinth of size and design as per manufacturer instruction with slot and clamps for incoming and outgoing cable protection pipe complete all as specified and directed. (z) Surge Protection device complete all as specified and directed
(aa) Earthing with 600x600x6.00mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Galvanised steel Strip of size 32 x 6 mm by means of bolts, nuts and check nuts and washers of galvanized steel with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 (Using 20 mm graded stone aggregate) with MS angle iron frame, CI Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed.
(ab) Earthing with copper earth plate 600x600x3mm, earth plate electrode buried vertically in ground (earth pit not less 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including copper earth strip of size 25 x 3 mm by means of bolts, nuts and check nuts and washers of copper steel with and including 40 mm dia GI medium grade pipe for protection of copper strip to the extent of 7.5 metres as earthing lead all as per Electrical Plate No 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 (Using 20 mm graded stone aggregate) with MS angle iron frame, CI Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete. Note:- Number of earthings shall be provided as required at site as per IE/IEC rule.
Supply installation, testing and commissioning SF6 insulated VCB HT 11 KV, 3 Phase, 50 HZ, indoor type, totally enclosed / metal clad switch gear complete having rupturing capacity of 400 MVA, 630 A , overload, earth fault and short circuit protection, Voltmeter range (0-15 KV) and Ammeter (0-500 Amp), required battery bank with charging arrangement, complete of following specifications mentioned in IS/IEC 62271 -100 & 200 including latest amendments / additions including followings:- (a) Motorized spring charging mechanism with 24 volt DC universal motor 200 watts and having charging time less than 10 seconds. including manual closing / tripping push button (b) Bus Bar Chamber including a set of 3 phase copper bus Bars (c) Dual core dual ratio Current Transformer (CT) chamber comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not more than 15 VA and accuracy class 0.5, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 01 Set (d) Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, Burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses / MCB for primary and secondary complete all as specified and as directed as per IS: 3156 - 01 Set (e) SCADA compatible self powered IDMT numerical relays, over current & earth fault relay with high adjustable setting, short circuit fault relay for complete protection of HT ,11 KV,3 Phase feeder having facility to record fault current with MODBUS communication on RS 485 communication port - 01 No. including 1 No voltage monitoring relay for under voltage / over voltage protection. (f) Earthing switch rated for full making capacity with provision for safe & reliable position indicator.
(g) (i) Assembly of Vacuum Circuit Breaker shall be completely insulated as per the relevant IS/IEC. (ii) The vacuum interrupter bottle shall be of the same make of VCB. (iii) Spring charged and electrically operated independent closing / tripping, trip free, operating mechanism and breaker close / open 0ption shall be provided. (iv) VCB should be SF6 insulated and has to be integrated with existing panel. Cost of integration is included in quoted rates
All as per Sl Item No. 10.11 & 10.12 above but for Outdoor type and to be installed in isolation complete all as specified and directed.
S&F 4 Module Gang box including Modular socket outlet 16 Amps for AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) including concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed.
S&F for sheet steel enclosure for mounting MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F of Monoblock centrifugal pump set suitable for operating with 3 Phase, 415 Volt AC 50 Hz supply and having ingress protection level IP-55, Class of insulation 'F', ISI Marked complete with bronze impeller, Stainless Steel shaft and all necessary hardware and pipe fittings / gasket. The pump set shall be duly fixed on rubber mountings and necessary electrical / earthing connection complete suitable to meet the following parameters: a) Operating Head : 23 Mtr b) Capacity : 5.0 HP c) Suction : 50mm d) Delivery : 80 mm e) Rated RPM : 1400
S&F DOL starter in sheet steel enclosure, 3 Phase, 415 Volts, 50 Hz, motor rating AC-3 duty, relay range 9-15 Amps, suitable for motor up to 10 Hp, all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks, 5000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed.
Cutting into existing manholes for connecting new drains and making good to pipe and rendering cutting out existing bending for and forming branch channel in cement concrete 1:2:4 type B-1 ( Using 20 mm graded stone aggregate) smooth finished and reforming benching as required for pipe 150 mm bore complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (top edge of the plate not less than 1.5 metres below normal ground level) connected to GI wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including 20 mm GI tubing medium grade and necessary fitting for protection of GI wire including laying of charcoal dust and common salt in alternate layers of 150mm the PCC chamber using PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate), RCC cover 40mm thick (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) reinforced with 8 mm dia round bars @ 75 mm C/C both ways with MS Handle 8 mm dia, plastering 15 mm thick CM (1:6) externally up to 150 mm below ground level, GI funnel with 20 mm dia medium grade GI Pipe for watering and wire mesh including excavation and earthwork and disposal of surplus soil complete all as specified and shown on Electrical plate No. 3 of SSR Part-I (2009) and connected to earth test point including testing and marking Building Nos and writing Test Results (in white) on blank painted M.S. Plate (size 300x300x3 mm) duly welded with angle iron of size 40x40x5 mm, 60 Cm long, fixed with the earth pit chamber by grouting complete including testing all as specified and directed. Note:- (i) GI wire and GI pipe medium grade, upto 7.5m shall be deemed to be included in the rates quoted. (ii) Excavation and earthwork in any type of soil strata shall be deemed to be included in the rates quoted. (iii) The Steel work, RCC , PCC work shall be deemed to be included in the rates quoted.
M& L for cutting of existing steel tubing 50 mm dia for alteration or additions without taking down in position complete all as specified and as directed.
M&L for construction of new valve chamber size 900mmx900mmx750mm including necessary earth work in any type of soil, PCC foundation (1:3:6 ) type C-2 (Using 40mm graded stone aggregate) as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in (up to 15 cm below NGL) CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40x40x6 mm MS angles complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coats of white wash on all plastered surface of valve chambers complete all as specified and as directed.
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
M & L for earthing for machinery/equipment using GI pipes of 60 mm dia & 4 feet length as earthing lead and MS galvanised earth plate of suitable size.Note:-(i) GI wire and GI pipe medium grade, upto 7.5m shall be deemed to be included in the rates quoted.(ii) Excavation and earthwork in any type of soil strata shall be deemed to be included in the rates quoted.(iii) The Steel work, RCC , PCC work shall be deemed to be included in the rates quoted.
M&L for Septic tank 10 Users designed to carry sewage and sullage water complete all as specified and shown on TD drawings.
M&L for Soakage wells of size 2.4m dia and 3.0m effective depth etc complete all as specified and shown on TD drawings.
S&F FRP Junction box, three phase complete with Bakelite connector 04 Nos 20 Amps busbar capacity 4 way supported on FRP/DMC insulator, MCB SP 06 Amps capacity with necessary fixing arrangements by providing MS clamps 01 No made out of MS flat 25x3 mm painted with one coat primer & two coats of paint including nuts, bolts etc complete all as specified and directed.
Sch A Part XI : Security Power fencing (PRIME COST SUM)
Supply, install, testing and commissioning of Energizer with onboard LCD and keypad having in built alarm unit and 90 dB Siren complete with following electrical parameters as confirming to safety standard : IEC 60335-76, IS-8437 (Part-I Human safety) and EMC directives:- 02 Nos (a) Operating Voltage : 12 V Dc (b) Output current : 500 mA (c) Output voltage 6 KV/9.9 KV Pulsating (d) Pulse interval : 1.2 Seconds (At 500 Ohms non inductive load) (e) Nos of Pulses : 50 Pulses/Min (f) Pulse width : 250 micro second (at 500 Ohms non inductive load) (g) Output power : > 2.5 Joules Including provision of following accessories as designed OEM:- (i) S&F Live light as designed by OEM:- 02 Nos (ii) S&F maintenance free battery 12 Volts, 7 AH with backup more than 4 hours :- 02 Nos (iii) Supply, install, testing and commissioning of Dual channel lighting diverter kit with all parts and accessories as designed by OEM :- 02 Nos (iv) S&F outdoor console rack as designed and suitable for power fence system by OEM :- 01 No (v) S&F Strain post 40 Sqmm of 1.5 meter length duly galvanized all as required :- 20 Nos (vi) S&F 32 NB Class B support post of suitable length for Strain posts :- 20 Nos (vii)S&F intermediate post of 25x25x3 MM T angular of 1.5 meter length duly galvanized :- 135 Nos
(viii) S&F intermediate post insulators with required. accessories fixed properly in existing holes of angel iron intermediate post :- 1080 Nos (ix) S&F end strain hooks as design by OEM :- 160 Nos (x) S&F end strain insulators as design by OEM :- 160 Nos (xi) Supply, fixing joint clamps suitable to interconnect HT wire of size 2.59mm dia as OEM manufactured :- 160 Nos (xii) Supply, fixing wire tighteners suitable for tightening of HT wire of size 2.59mm dia as manufactured by OEM :- 80 Nos (xiii) S&F HT wire of size 2.59 mm dia as manufactured by OEM :- 3780 Rm (xiv) M & L for double insulated cable to connect fence with Electronic system 2mm dia GI wire having double insulation with overall diameter of 9 mm having withstanding capacity of more :- 100 Rm (xv) Supply, install warning sign board of size 250x150x3mm dimensions as design by OEM :- 45 Nos (xvi) M&L for earthing for machinery/equipments using GI pipes of 60 mm dia and 4 feet length as earthing lead and MS galvinised earth plate of suitable size. :- 04 Nos
Sch A Part XII : Maintenance & operation of Solar plant
Services for maintenance & operation of Solar power plant for 33 months (including 24 months defect liability period) in two shifts including Saturday, Sunday & holidays after completion of project as per conditions of contract including the following:- (i) The work order for outsourcing of services shall be placed for eleven months & no price adjustment for its extension shall be permissible. The Solar Power Plant shall be operated in 02 shifts per day unless otherwise directed by the Engineer-in-Charge/GE.(ii) The contractor shall deploy minimum tradesman as follows:- (a) One trained Electrician in each shift and one helper in first shift / general shift as decided by Engineer-in-Charge shifts for attending/monitoring the breakdown and preventive maintenance. Note: Penalty Clause:-If the installation (Solar Power Generation Station) is not operated by the electrician and helper or found absent from duty the penalty for this lapse shall be final and binding as under:-Skilled Electrician: - Double the rate of minimum wages published by the GOI or double the rate quoted by the contractor which ever is higher during the absent period. Helper: - Double the rate of minimum wages published by the GOI or double the rate quoted by the contractor which ever is higher during the absent period.(iii)The electrician must have ITI in Electrical trade and having experience of 02 years in operation & maintenance of solar power plant and familiar with SCADA operating system, weathering monitoring system, HT/LT installation and security and safety features complete. The Necessary technical qualification certificate shall be produced for verification of Engineer-In-Charge & get the written approval on record before deploying for works.
(iv) Contractor shall offer service for entire system as per inspection/ maintenance schedule as given in particular specification and as directed by Engineer in Charge and maintain necessary record for the same.Contractor shall also ensure the following:- (aa) Servicing of all solar equipment HT/LT control system, Transformers weather monitoring equipment’s SCADA system etc all as per OEM. (ab) Cleaning of Solar PV modules by washing, sprays, brushes, tools and plants, any washing solutions as per OEM recommendations & as per laid down norms for solar power plant complete as directed by the Engr-in-charge/GE including providing arrangements for taking water from tapping point to modules. (ac) Checking of meter readings and recording in log book in the format and as per instruction given by Engineer- in- Charge. (ad) The Engineer/Electrician shall submit reports in soft and hard copy format as required by the Engineer- in- Charge. (ae) Safety, security of all E&M equipment solar panels, T&P and Sub Station complete all as directed by the Engineer-in-charge. (af) Area cleaning removing of grasses, bushes etc as per the instructions of Engineer- in- Charge. (v) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (vi) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be all inclusive and includes for required Spares, services labour, handling and transportation charges etc. (vii) Proper & efficient functioning of the plant must be ensured through regular inspection by qualified engineer of MNRE approved vendor of Category ‘A’ as per inspection/ maintenance schedule and rate quoted will be inclusive of the same.
(viii) Contractor shall arrange training one month for operation and maintenance to MES tradesman before handing over the installation to MES as directed by GE Note: Contractor shall also provide portable fire extinguisher of required capacity and quantity at the power house/installation. Note:- All stationery, T&P, items required to maintain the Installations, for keeping in a presentable manner and to keep plant in 100% function able condition, payment of requisite charges and fees for SCADA to third party / SCADA OEM, are deemed to be Included in the cost of quoted rate.
First 11 Months
Second 11 Months
Third 11 Months
M/s godara infratech and power industries
Phoenix Infra
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .