| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LQualified Make: BPE
Model: BPE 1 KVA 168 VAH Line Interactive 1 Year AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 1 KVA 168 VAH Line Interactive 1 Year | ₹1.6 L | L1 | Qualified |
| 2 | L2₹1.7 L+₹13,520 (8.70%)Qualified Make: PARADYNE
Model: PDFN1-1000-867 B 187 DDA SHED OKHLA INDUSTRIAL AREA OKHLA INDUSTRIAL AREA PHASE I NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: PARADYNE
Model: PDFN1-1000-867 | ₹1.7 L+₹13,520 (8.70%) | L2 | Qualified |
| 3 | L3₹1.7 L+₹16,120 (10.4%)Qualified Make: ELNOVA
Model: ELNOVA, I1002 40 1A BASAPPA COMPLEX BANGALORE INDIA KARNATAKA BANGALORE CITY KARNATAKA 560001 | BENGALURU URBAN | KARNATAKA | 560001 | Make: ELNOVA
Model: ELNOVA, I1002 | ₹1.7 L+₹16,120 (10.4%) | L3 | Qualified |
| 4 | L5₹1.8 L+₹22,464 (14.4%)Qualified Make: VERTIVE
Model: Liebert itON-CX-1000 | Make: VERTIVE
Model: Liebert itON-CX-1000 | ₹1.8 L+₹22,464 (14.4%) | L5 | Qualified |
| 5 | L6₹1.8 L+₹26,468 (17.0%)Qualified Make: zebronic
Model: Zebronics U1200 ASHRAM NEW DELHI DELHI 110014 | SOUTH EAST DELHI | DELHI | 110014 | Make: zebronic
Model: Zebronics U1200 | ₹1.8 L+₹26,468 (17.0%) | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 May 2018, 2:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 52 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through No Yes
No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date R-41018082 - Name Of Lab BIS - Address of Lab CHANDIGARH - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anant Vaibhav 110010
Room NO 110 A
B bLock Hutments
Dara Shikoh Road 52 45 EMD Required No ePBG Required No
104189
GEM/2018/B/14867
Line Intractive UPS with AVR
45 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 52 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through No Yes | - | - | - |
| No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date R-41018082 - Name Of Lab BIS - Address of Lab CHANDIGARH - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anant Vaibhav 110010 | - | - | - |
| Room NO 110 A | - | - | - |
| B bLock Hutments | - | - | - |
| Dara Shikoh Road 52 45 EMD Required No ePBG Required No | - | - | - |
Exempted
29 May 2018
18 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_104189.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .