Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical As per tender doccument |
Tender Value
₹27.1 L
EMD Value
₹54,180
Closing Date
8 Feb 2023, 3:00 pmClosed
AGM EM
FCI RO Lucknow
Improvement of existing power supply and internal and external illumination with LED lights at FSD Imalia under DO Bulandshahr.
2023_FCI_737678_1
EM/18/2022-23
Open Tender
Electrical Works
Item Rate
75 days
Imalia
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹54,180
24 Apr 2023
30 Jan 2023
9 Feb 2023
30 Jan 2023
8 Feb 2023
30 Jan 2023
Amount
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size as per direction of engineer in charge .
4 X 25 sqmm
4 X 10 Sqmm
2 X 10 Sqmm
Supply, installation, testing and commisioning of weather proof MS loop in loop out busbar box havin 4P MCCB 63Amp and of size not less than 450x350x200 mm with 4 Nos. suitable capacity ALU (upto 150 Amp) Bus Bar (R,Y,B & N) duly finished and painting, detachable gland plate & Arrangement for interconnection etc as required conforming to relevant BIS/IS codes.
Supply , Installation, Testing & Commissioning of integral well glass luminaire compressed of dia cast canopy gear box housing and glass driver surge with heat resistance glass of LED well glass fitting 35 to 40 watt, minimum 110 Lm/watt to 125 Lm/watt or Luminous should not be less than 4200, SPD with internal surge protection upto 4KV and External surge protection upto 10KV,Line voltage protection upto 8Hrs with autorestart having minimum 2 years warranty conforming to IS-16103-2012 or equivalent with upto date amendments as per direction of engineer in charge .
S/I/T/C of loop in loop out box made of PVC sheet 200 X 150 X 100 mm/suitable size having suitable size 2 nos. terminals and 01 no. SP MCB 5/6A detachable gland plate, interconnection etc. as required conforming to relevant BIS/IS codes.
Supply , Installation, Testing & Commissioning of LED Street Light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45 watt with IP66 protection having Luminous 110 Lm/watt to 125Lm/Watt or Luminous should not be less than 4800 and having SPD with internal surge protection upto 4KV and External surge protection upto 10KV,Line voltage protection upto 8Hrs ,autorestart having minimum 2 years warranty conforming to IS-16103-2012 or equivalent with upto date amendmentsas per direction of engineer in charge .
Supplying of 18 to 22 watt LED polycarbonate batten fixture with minimum 100 lumens/watt or Luminous should not be less than 2000 having minimum 2 years warranty (conforming to IS-16103 part 2 (2012) with upto date amendements or equivalent) as per direction of enginner in charge
Replacement and refixing of following size of steel conduit along with all accessories in surface/recess incuding painting etc. in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supply of 1200 mm sweep 5 star ceiling fan conforming to IS 374-1979 or equivalent.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required conforming to IS-2675(1983) or equivalent. (But without MCB/RCCB/Isolator) - 4 way (4+12) double door.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required conforming to IS-2675 (1983) or equivalent. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing metal box of sizes 200 mm X 150 mm X 75 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required conforming to IS 14772(2000) or equivalent.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections , painting etc. as required conforming to IS 3854(1997) or equivalent. 5/6 amps switch
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required conforming to IS 13032/8623 or equivalent.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X .3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required conforming to IS-1239 Part-1(2004) or equivalent with upto date amendments.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required confirming to IS694-2010 or equivalent with upto date amendments as per direction of engineer in charge .
3 x 1.5 sq. mm
5 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class steel conduit along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required conforming to IS-9537(Part3) or equivalent with upto date amendments. 25 mm
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but .excluding sand cushioning and protective covering etc., complete as required as per direction of engineer in charge .
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required conforming to IS-1239 Part-1(2004) or equivalent with upto date amendments.
50 mm dia
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35 sq. mm
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required conforming to IS12943(1990) or equivalent.
4 X 25 sq. mm (28mm)
4 X 10 sq. mm (25mm)
2 X 10 sq. mm (19mm)
Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required conforming to IS-1239 Part-1(2004) or equivalent with upto date amendments.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required conforming to relevant BIS/IS codes
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required conforming to relevant BIS/IS codes
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required conforming to relevant BIS/IS codes.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required conforming to relevant BIS/IS codes.. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required conforming to relevant BIS/IS codes.(For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required conforming to relevant BIS/IS codes.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required conforming to relevant BIS/IS codes as per direction of engineer in charge ..
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following rating , 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required conforming to IS-IEC60898-1 or equivalent with upto date amendments.
Single pole
Double Pole 32 A
Triple Pole & Neutral 63A
Credit for dismantelled/damaged items:-
Aluminium Scrap ( i.e., Cables etc)(L.S.)
Iron Scrap (Steel tubular poles, dismantled iron conduits etc.)(L.S.)
Copper Scrap (old wires, HPSV ballast etc)(L.S.)
NEW VICKY ENTERPRISES
chauhan and associates
M/S. O. P. CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .