| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted lowest amount. | |
| 2 | L2₹10.2 L+₹13,443 (1.33%)Rejected-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L2 | Rejected-Finance Bidder not quoted lowest amount. | |
| 3 | L3₹10.6 L+₹54,200 (5.37%)Rejected-Finance 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-Finance Bidder not quoted lowest amount. | |
| 4 | L4₹10.9 L+₹83,685 (8.28%)Rejected-Finance 454 5 SHOP NO 3 COMMERCIAL COMPLEX AZADPUR DELHI DELHI 110033 | NORTH DELHI | DELHI | 110033 | L4 | Rejected-Finance Bidder not quoted lowest amount. | |
| 5 | L5₹11.0 L+₹86,325 (8.55%)Rejected-Finance C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | L5 | Rejected-Finance Bidder not quoted lowest amount. |
Tender Value
₹12.0 L
Closing Date
13 Nov 2021, 6:00 pmClosed
Jt. GM (Engg-E)
Jt. GM (Engg-E), AAI, Electrical Maintenance Division, Amritsar Airport.
Replacement of old split/window ACs and provision of new split type ACs at NAV AID sites of SGRDJI Airport, Amritsar (2021-22).
2021_AAI_93668_1
AAI/ASR/ENGG-ELECT/ENIT-07
Open Tender
Electrical Works
Works
120 days
Amritsar Airport
As per Tender Document
17 documents required · 17 mandatory
₹1,180
Exempted
23 Dec 2021
3 Nov 2021
16 Nov 2021
3 Nov 2021
13 Nov 2021
3 Nov 2021
3 Nov 2021 - 8 Nov 2021
Amount
SITC of 2 Ton Inverter Type Split A.C of minimum ISEER rating 4.50 as per latest BEE guidelines (equivalent to erstwhile BEE 5 Star rating), 100% Copper consisting of single room unit (evaporator unit) with cordless remote control, digital temperature display and one outdoor condensing unit comprising of sealed rotary/twin-rotary/BLDC type compressor suitable for stabilizer free operation at 230 V,50 Hz supply and non CFC refrigerant like R- 410A/R32 capable of performing a) cooling b) de-humidifying c) Air- Circulation d) filtering. Interconnection, pipelines/cables along with PVC pipe for protection, refrigerant copper tubes (approx 3 mtrs) along with PVC pipe for protection, insulation tubes, insulating tapes, first charge of refrigerant (if required), installation of outdoor & Indoor units in wall with supply of mounting bracket, painting, sealing, civil finishing etc., complete as required. Make- as per approved make list of AAI.
Supply
Installation, Testing & Commisioning
SITC of 1.5 Ton Inverter Type Split A.C of minimum ISEER rating 4.50 as per latest BEE guidelines (equivalent to erstwhile BEE 5 Star rating), 100% Copper consisting of single room unit (evaporator unit) with cordless remote control, digital temperature display and one outdoor condensing unit comprising of sealed rotary/twin-rotary/BLDC type compressor suitable for stabilizer free operation at 230 V,50 Hz supply and non CFC refrigerant like R- 410A/R32 capable of performing a) cooling b) de-humidifying c) Air- Circulation d) filtering. Interconnection, pipelines/cables along with PVC pipe for protection, refrigerant copper tubes (approx 3 mtrs) along with PVC pipe for protection, insulation tubes, insulating tapes, first charge of refrigerant (if required), installation of outdoor & Indoor units in wall with supply of mounting bracket, painting, sealing, civil finishing etc., complete as required. Make- as per approved make list of AAI.
Supply
Installation, Testing & Commisioning
Dismantling of existing split ACs of different capacities (1.5/2 TR) including existing copper piping and stacking them in a proper manner at a place designated by Engineer-in-Charge.
Supply of metal-based Automatic Voltage Stabilizer of following capacity with high / low cut off complete as reqd. suitable for input voltage from 160 to 280 volt giving output 200-240 volt at 50 Hz A.C. Supply. The stabilisers should be suitable for 1.5 & 2 TR ACs. a) 5 KVA
Supply and fixing of 25mm dia PVC drain pipe from the respective units, clamping on different surface like wall/floor etc. i/c sealing the joints with making of openings as per site condition. (to be measured for lengths exceeding the cumulative length of 3 metres per AC which is already in scope of item 1 & 2)
Supply and fixing (in wall or ground) of colour painted M.S. angle iron frame of approx. 35x35x5mm size and mounting of outdoor A.C. units on the stand complete as reqd. Size of the frame can vary as per size of the outdoor units. The contractor shall ensure that the supplied frames are of proper size for the supplied ACs i.e. the outdoor units fit properly in the supplied stand.
Supply & fixing of suitable size Copper Refrigerant piping (Supply and return) with expanded polythene foam insulation tubing covering and protection with PVC pipe of suitable diameter for for 1.5 TR/2 TR A/c units. Measurement of 1 Mtr. Will include both supply & return Cu. Piping with insulation. (to be measured for lengths exceeding the cumulative length of 3 metres per AC which is already in scope of item 1 & 2)
Supply and fixing of following size 1.1 kv graded PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable (along with protection with PVC pipe of suitable diameter), conforming to IS 694with upto date amendments as required of approved make. a) 4 core x 2.5 Sq.mm (to be measured for lengths exceeding the cumulative length of 3 metres indoor-outdoor power cum control cable per AC which is already in scope of item 1 & 2)
SITC of timer for automatic switching on/off of AC units (1.5/2 TR) suitable for 230 V AC supply etc. as required and conforming to relevant specifications. There should be a provision of changing the time setting (duration) and operating the AC units in manual mode as well. The number of ACs to be controlled and number of ACs to be switched on (be in operation) at a time are given below:
1 out of 2 installed Acs to be switched on at a time
Anoop Refrigeration
Arctic Engineering Services
AIR CARE REFRIGERATION SYSTEM PVT. LTD.
ANU ENGINEERING CORPORATION
Manish Electricals
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .