Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.4 L+₹1.1 L (13.9%)Rejected-Finance PALRI ROAD NUH 144 NUH MEWAT | NUH | MEWAT | HARYANA | L2 | Rejected-Finance L2 |
Tender Value
₹6.2 L
EMD Value
₹12,500
Closing Date
28 Feb 2020, 5:00 pmClosed
Rajesh Ahuja
XEN (E) Rewari
CONSTRUCTION OF 17 NO. STUDIO APARTMENT and 1 NO. RECREATION ROOM IN CAMPUS OF CIVIL HOSPITAL AT MANDIKHERA IN DISTT. NUH (PDG. E.I. INTERNAL WITH FAN and FITTINGS ONLY).
2020_HRY_118325_1
CONSTRUCTION OF 17 NO. STUDIO APARTMENT and 1 NO.
Open Tender
Electrical Works
Works
90 days
XEN (E) Rewari
Refer DNIT
2 documents required · 2 mandatory
₹1,000
Executive Engineer,Electrical Division
₹12,500
27 Sept 2021
14 Feb 2020
29 Feb 2020
14 Feb 2020
28 Feb 2020
14 Feb 2020
Amount
Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections . Double pole switch 32 amp 240 Volts Cat-B.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Supply and erection of blanking sheet in existing distribution board.
Supply and erection of miniature circuit breaker/ isolator 240/415 V in the existing distribution board including making necessary connection. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
Supply and erection of Fittings and Accessories. Call bell 220 / 230 volts A.C. bakelite with double coil.
Bakelite angle / straight button holder large size.
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod mAde into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Supply and erection of 75 mm x75 mm x 60 mm deep M.S.box for telephone and inter-communication system including 2 pin 5 amp. socket including cost of bakelite sheet .
Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point Medium Point .
Long Point .
Light point Short Point
Long Point .
Twin control light point with 2 way 5 amp. single pole switch Short point.
Long point.
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell Long point
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point.
Long point.
3 pin 15 amp. plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable. Long point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Cable size 1.5 sq.mm(3/ 0.81 mm)
Cable size 4.0 sq.mm(7/ 0.85 mm)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. 8 way SP&N (Horizontal)
Supply & erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection boxe and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. 25 mm dia
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer-in-Charge of the Work.
Supply & erection of Celing Fans 1200mm / 48" Size Crompton / Bajaj / Khaitan/ Orient or approved Make complete in all respect upto the entire satisfaction of the Engineer- in -Charge of work
Supply & erection of Ex. Fans 12" Size Crompton / Bajaj / Khaitan/ Orient or approved Make complete in all respect upto the entire satisfaction of the Engineer- in -Charge of work
Supply & erection of LED fitting 18w., Crompton / Bajaj / GE / Philips / Jaquar or approved Make complete in all respect upto the entire satisfaction of the Engineer- in -Charge of work
Nitin Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .