Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.1 Cr+₹21.2 L (11.4%)Admitted-Finance PLOT NO 61 BLOCK NO 7 WARD NO 1 GURGAON HARYANA 122001 | GURGAON | GURGAON | HARYANA | 122001 | ₹2.1 Cr+₹21.2 L (11.4%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical C 27 MANOJ C 27 SUKHWANI GANESH NAGAR DAPODI DAPODI PUNE MAHARASHTRA 411012 | PUNE | MAHARASHTRA | 411012 | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | Purvi Engineers India Pvt Ltd L1 | Industrial Project and Products Company L2 |
|---|---|---|---|---|---|
| 1.00 | Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery, site Installation and erection along with its support and site Testing of Single Louvered Isolation dampers (butterfly type): – for exhaust filter bank inlet/outlet with flexible metallic sealing to ensure leak tightness of minimum 99.8%, Double acting Rotary type pneumatic actuator for the following sizes as per the specifications: size 700 x 1100 x 250 mm. | 6 | Nos. | 52,200.9 ₹3,13,205.4 Lowest | 4,25,000 ₹25,50,000 |
| 2.00 | Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Packing, safe Delivery, site Installation and erection along with its supports & structure and site Testing of Exhaust system MS filter bank along with its leak tight door (MS), SS304L filter retainer frame for Pre and HEPA filter (4 x3 module) as per the specification and approved drawings. All the consumables will be in the scope of vendors. | 3 | Nos. | 11,43,420 ₹34,30,260 | 10,50,000 ₹31,50,000 Lowest |
| 3.00 | Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, proper packing between fan & wall, site Testing and Commissioning of Tube Axial Fans complete with motor necessary protection equipment, epoxy painting, cables, installation frame, flexible connection at inlet & outlet, vibropad, wall cowl with bird mesh etc. and electrical wiring with plug top from the nearest socket point for fan as per the specifications.
Capacity 12,000 m3/hr @ static pressure 25 mm WG | 2 | Nos. | 83,715.1 ₹1,67,430.2 | 27,500 ₹55,000 Lowest |
| 4.00 | Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, site Testing and Commissioning of Propeller Fans complete with motor, cables, installation frame, epoxy painted, wall cowl with bird mesh etc. and electrical wiring with plug top from the nearest socket point for fans as per the specifications.
Capacity 2,500 m3/hr @ static pressure 10 mm WG | 15 | Nos. | 26,004.4 ₹3,90,066 | 15,000 ₹2,25,000 Lowest |
| 5.00 | Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, site Testing and Commissioning of Propeller Fans complete with motor, cables, installation frame, epoxy painted, wall cowl etc. and electrical wiring with plug top from the nearest socket point for fans as per the specifications.
Capacity 500 m3/hr @ static pressure 5 mm WG | 6 | Nos. | 23,502.6 ₹1,41,015.6 | 9,800 ₹58,800 Lowest |
| 6.00 | Procurement, Supply, Installation & Performance Testing of Split Air Conditioner (Cassette Type, copper tube indoor and outdoor unit) with associated piping and electrical wiring with plug top from the nearest socket point, 2 TR, 5 Star rating, refrigerant with suitable starter as per specification. | 2 | Nos. | 1,20,440.2 ₹2,40,880.4 | 1,04,200 ₹2,08,400 Lowest |
| 7.00 | Procurement, Supply, Installation & Performance Testing of Split Air Conditioner (copper tube indoor and outdoor unit) with associated piping and electrical wiring with plug top from the nearest socket point, 2 TR, 5 Star rating, refrigerant with suitable starter as per specification. | 3 | Nos. | 76,513.9 ₹2,29,541.7 | 75,000 ₹2,25,000 Lowest |
| 8.00 | GI Duct (20G, Grade 120 gm/m2 Zinc Coating as per IS 277): Preparation of fabrication drawings/site erection drawings, Procurement of material, fabrication, installation complete with supports out of angles / channels /rods, anchor fasteners wherever required, GS nuts, bolts, gaskets, testing and as per the specifications. This cost will be based on the weight of actual GI sheet used. However, support material, stiffener etc. & its fabrication cost will be paid separately as per item no. 10. | 10,000 | Kg | 135.7 ₹13,57,000 Lowest | 220 ₹22,00,000 |
| 9.00 | M.S. 3 and 5 mm thick return air duct: Preparation of fabrication drawings, site erection drawings, Procurement of material, fabrication, installation, LPT test complete with supports out of angles / channels /rods, anchor fasteners wherever required, all welded joints with its support, testing, painting and as per the specifications. This cost will be based on the weight of actual MS sheet used. However, support material, stiffener etc. & its fabrication cost will be paid separately as per item no.10. All the consumables will be in the scope of vendor. | 28,000 | Kg | 182.9 ₹51,21,200 | 180 ₹50,40,000 Lowest |
| 10.00 | Procurement of material , preparation of drawings, fabrication, supply and installation of M.S. Support for ducts, plenums, structural supports, ducts stiffeners, bracings, fan support, etc. along with epoxy primer and epoxy painting (angle/ channel /plate/ pipe / rod/fasteners etc.). All the consumables will be in the scope of vendor. | 28,000 | Kg | 152.5 ₹42,70,000 Lowest | 185 ₹51,80,000 |
Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
21 Feb 2025, 3:00 pmClosed
Project Director, INRPC
Project Director Office INRPC, BARC, Tarapur, Boisar, MH-401502
Procurement, Fabrication, Delivery, Testing, Installation, Erection and Commissioning of Ventilation System in Block-114 at INRPC Site
2025_NRB_842937_1
BARC(T)/NRB/INRPC/MPT 537/2025/05
Open Tender
Machineries/ Mechanical Engg Items
Works
365 days
INRPC NRB BARC Tarapur
refer tender doc
4 documents required · 4 mandatory
₹0
₹4 L
Yes
Conferance Room, Project Director office INRPC
17 Apr 2025
9 Jan 2025
28 Feb 2025
9 Jan 2025
21 Feb 2025
17 Jan 2025
9 Jan 2025 - 13 Jan 2025
14 Jan 2025
Amount
Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery, site Installation and erection along with its support and site Testing of Single Louvered Isolation dampers (butterfly type): – for exhaust filter bank inlet/outlet with flexible metallic sealing to ensure leak tightness of minimum 99.8%, Double acting Rotary type pneumatic actuator for the following sizes as per the specifications: size 700 x 1100 x 250 mm.
Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Packing, safe Delivery, site Installation and erection along with its supports & structure and site Testing of Exhaust system MS filter bank along with its leak tight door (MS), SS304L filter retainer frame for Pre and HEPA filter (4 x3 module) as per the specification and approved drawings. All the consumables will be in the scope of vendors.
Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, proper packing between fan & wall, site Testing and Commissioning of Tube Axial Fans complete with motor necessary protection equipment, epoxy painting, cables, installation frame, flexible connection at inlet & outlet, vibropad, wall cowl with bird mesh etc. and electrical wiring with plug top from the nearest socket point for fan as per the specifications. Capacity 12,000 m3/hr @ static pressure 25 mm WG
Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, site Testing and Commissioning of Propeller Fans complete with motor, cables, installation frame, epoxy painted, wall cowl with bird mesh etc. and electrical wiring with plug top from the nearest socket point for fans as per the specifications. Capacity 2,500 m3/hr @ static pressure 10 mm WG
Design, Procurement of material , Preparation of fabrication drawings and site erection drawings, Fabrication, Inspection, Shop testing, Packing, safe Delivery at INRPC site, site Installation & erection along with its support, site Testing and Commissioning of Propeller Fans complete with motor, cables, installation frame, epoxy painted, wall cowl etc. and electrical wiring with plug top from the nearest socket point for fans as per the specifications. Capacity 500 m3/hr @ static pressure 5 mm WG
Procurement, Supply, Installation & Performance Testing of Split Air Conditioner (Cassette Type, copper tube indoor and outdoor unit) with associated piping and electrical wiring with plug top from the nearest socket point, 2 TR, 5 Star rating, refrigerant with suitable starter as per specification.
Procurement, Supply, Installation & Performance Testing of Split Air Conditioner (copper tube indoor and outdoor unit) with associated piping and electrical wiring with plug top from the nearest socket point, 2 TR, 5 Star rating, refrigerant with suitable starter as per specification.
GI Duct (20G, Grade 120 gm/m2 Zinc Coating as per IS 277): Preparation of fabrication drawings/site erection drawings, Procurement of material, fabrication, installation complete with supports out of angles / channels /rods, anchor fasteners wherever required, GS nuts, bolts, gaskets, testing and as per the specifications. This cost will be based on the weight of actual GI sheet used. However, support material, stiffener etc. & its fabrication cost will be paid separately as per item no. 10.
M.S. 3 and 5 mm thick return air duct: Preparation of fabrication drawings, site erection drawings, Procurement of material, fabrication, installation, LPT test complete with supports out of angles / channels /rods, anchor fasteners wherever required, all welded joints with its support, testing, painting and as per the specifications. This cost will be based on the weight of actual MS sheet used. However, support material, stiffener etc. & its fabrication cost will be paid separately as per item no.10. All the consumables will be in the scope of vendor.
Procurement of material , preparation of drawings, fabrication, supply and installation of M.S. Support for ducts, plenums, structural supports, ducts stiffeners, bracings, fan support, etc. along with epoxy primer and epoxy painting (angle/ channel /plate/ pipe / rod/fasteners etc.). All the consumables will be in the scope of vendor.
Flow balancing dampers for supply and exhaust ducting (Al powder coating with gear operated manual operated): Procurement, supply, installation, testing and comissioning as per the specifications. (Cost is based on area of the duct in which damper is installed.)
Supply air grilles with opposed blade volume control dampers (VCD), (18 G thk. Aluminium section with powder coating): Procurement, Supply, Installation, and Testing as per the specifications. (Cost is based on the neck area of the grill.)
Return air grilles with opposed blade volume control dampers (VCD), (18 G thk. Aluminium section with powder coating): Procurement, Supply, Installation, and Testing as per the specifications. (Cost is based on the neck area of the grill.)
Procurement, Supply, fabrication, installation and Testing of 15 NB (200mm length) threaded MS nozzle with metallic cap on supply and exhaust duct / Plenum as per requirement
Procurement, Supply and installation and erection of approved make GI Coated Anchor fasteners as per standard specifications (Size M12 x minimum length 140mm, as per code ACI 349 and NQA-1)
Procurement, Supply, Fabrication ,Installation and Erection of MS plate E.P. (200mm x 200 mm x minimum 10mm thk.) with anchor fasteners(Anchor mentioned in Item no 15) at locations wherever E.P are not available at site.
Dismantling of concrete solid block masonry in cement morter ( cut out expansion in RCC concrete wall if required) carefully without damaging adjacent structure including stacking of materials and disposal of unserviceable materials within 500 m lead as directed by Engineering In-Charge
Providing 12 mm thick internal & 20mm thick external plastering in cement mortar 1:4 without cement punning (using fine river sand ) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site.
Procurement and Supply of complete set of of measurement instrument for commissioning of the ventilation system. The instruments include i. Hot Wire Anemometer: 2 Nos. ii. Vane Type Anemometer: 2 Nos. iii. Digital Manometer: 2 Nos. iv. Vibrometer: 2 Nos. v. Tachometer: 2 Nos. vi. Non-contact type thermometer : 2 Nos
Air flow balancing, testing and commissioning of entire Ventilation System inclusive of supply and exhaust system as per the technical specification.
LPBS: Design, manufacture, testing and supply of local push button stations (MOC- FRP) as per the technical specification.
supply
Installation
Industrial Project and Products Company (BID ID -3168021)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
TENDERDOCUMENTMPT537.pdf
Tender Documents • 12.76 MB
BOQ_886057.xls
BOQ • 0.26 MB
TechnicalBidMPT537.xls
Additional Documents • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .