Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-Finance | ₹5.6 L | L1 | Accepted-Finance OK |
| 2 | L2₹6.0 L+₹41,436.06 (7.46%)Rejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | ₹6.0 L+₹41,436.06 (7.46%) | L2 | Rejected-Finance EMD TO BE REFUND |
| 3 | L3₹7.2 L+₹1.6 L (29.7%)Rejected-Finance 677 2 DIAMOND HARBOUR ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | ₹7.2 L+₹1.6 L (29.7%) | L3 | Rejected-Finance EMD TO BE REFUND |
| 4 | L4₹7.6 L+₹2.0 L (36.3%)Rejected-Finance | ₹7.6 L+₹2.0 L (36.3%) | L4 | Rejected-Finance EMD TO BE REFUND |
| 5 | L5₹7.8 L+₹2.2 L (39.7%)Rejected-Finance | ₹7.8 L+₹2.2 L (39.7%) | L5 | Rejected-Finance EMD TO BE REFUND |
Tender Value
₹7.7 L
EMD Value
₹15,318
Closing Date
30 Jan 2026, 5:00 pmClosed
EXECUTIVE ENGINEER ELECTRICAL ADDA
Vivekananda Sarani, Senraleigh Road Near Kalyanpur Housing More,Asansol -713305
Supply,Installation and Commissioning of LED High Mast lighting system with all accessories of Punjabi More IC PS-Raniganj Dist Paschim Bardhaman
2026_ADDA_988990_1
ADDA/ASN/ED/N-68(2025-2026)
Open Tender
Electrical Work/ Equipment
Percentage
90 days
ADDA ASANSOL
Please refer as uploaded documents
3 documents required · 3 mandatory
₹0
₹15,318
10 Apr 2026
17 Jan 2026
3 Feb 2026
17 Jan 2026
30 Jan 2026
17 Jan 2026
Supply & delivery at site of 12.5 Mtr. high mast lighting tower in two section, single weld and single dip galvanized with head frame, pulley assembly, lantern carriage, rubber padded guide ring, double drum winch, s/s wire ropes, multi core copper trailing cable suitable for HM lighting Tower ,power tool with contactor based reversible starter, lighting arrester, distribution box. Sheet thickness for the bottom & top section shall be at least 3 mm and the larger diameter of the bottom section shall not be less than 410mm ,Top dia 150 mm & PCD 490. (Make – BPP/Bajaj/Uttakarsh Pipe) (Analysis rate)
Design & construction of civil foundation for 12.5 m High Mast, taking actual site condition into account including excavation of earth, supply of cement sand ,reinforcement steel bars, shuttering materials, labour etc. complete with refilling of earth to the existing ground level locations of High Masts ,suitable measures are to be taken so as to ensure High Mast flange at 300 mm above the ground level. Prior approval of design parameters shall be necessary. (Analysis rate)
Assembly of 12.5 m High Mast with all its accessories, erection testing and commissioning of the same with the help of crane or derrick system, fixing and wiring of luminaries with all materials and labour.(Analysis rate)
Supply & fixing of Aviation Obstruction luminaire similar to Bajaj make, Cat No. BJAOL – 2 including CFL lamps and other accessories complete for ready use on lantern carriage. Make – Philips/Bajaj/Crompton.(Analysis rate)
Supply, fixing, connection & testing of outdoor type Flood light fittings of IP66, IK08 LED Integral type flood light luminaire with system lumen > 36000 system wattage not more than 405 W with pressure die cast aluminium housing, LM 80 For LED Source & LM79 for Luminaire is mandatory, Surge Protection Minimum 10 KV/KA. Make: Philips (Fittings Cat no. BVP485 LED 385 CW FLNB A1 PSU GR SPD P )/ Appvd. equivalent from Crompton/ Bajaj/ Wipro.(Philips Price)
Supply at the work site of 4C x 16 sq.mm Al. conductor, XLPE insulated, armoured, overall PVC sheathed, 1.1 KV grade power cable conforming to IS:7098(Part-1) 1988 with latest amendments. Make: Polycab / KEI / Havells. (Analysis rate)
Laying of cable in underground trench 460 mm wide x 760 mm average depth,with brick protection on the top of the cable with 8 (eight) Nos. brick per meter,including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restore the surface duly rammed. (PWD Schedule,2017,Page F-2, Item 1.a + 3% District Charge.
Laying of above cable through Pipe/Pole etc. PWD Schedule,2017, Page F-1, Item 3 (a) + 3% District Charge.
Supply, installation, commissioning & testing of outdoor type feeder pillar box made of 2 mm CRCA sheet duly rust inhibited and stove enamel painting, complete with rubber gasket, hinged door at least 800 x 450 x 200 mm in size projected top cover, suitable ventilation and MS iron frame work with adequate space for provision of WBSEDCL meter. The panel consisting with 63A TPN MCB incoming, Astronomical time switch, toggle switch, contractor of L&T make for automatic operation of street light system. (Analysis rate)
Earthing with 50 mm dia GI pipe 3.64 mm thick X 3.04 Mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 Mtrs long), 13 mm x 80 mm long GI nuts bolts with double washer including (ISI-Medium GI pipe) making digging of soil etc. complete. PWD PWD Schedule,2017, Page G-1,Item 2(a) + 3% District Charge.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode. PWD Schedule,2017 Page- G-2, Item 3 (b)+ 3% District Charge.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. PWD Schedule,2017 Page- F-6, Item 11 (d) + 3% District Charge.
Supplying fitting and fixing plaque made of Granite slabs ( single piece) of 15 mm to 18 mm thick with uniform texture and without decorative veins in facia etc fixing with using Cement slurry at back side of granite @4.4 kg/sq.m and white cement slurry for joint filling @1.8 kg/sq.m.including making lettering , sign marks etc as per direction in the granite slabs with fixed at brick wall (in 1:6) as directed including earth cutting , 75 mm thick sand filling , 75 mm thick Cement concrete (1:2:4) and plastering with 20 mm thick sand cement mortar (6:1) as specifed by the Department including wall putty , Acrylic primer & Super Protective 100% Acrylic Emulsion two coats including all incedential charges for labours, materials, machinaries & transportig charges complete in all respect as per direction of EIC.(Analysis rate)
Sub Total
Add GST @ 18% on Sub-Total Cost, i.e.
Add Labour Welfare Cess @ 1% on Total cost after GST, i.e.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.43 MB
Tendernotice_2.pdf
PDF • 2.00 MB
BOQ_2416151.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .